American Standard 7440.101 installation instructions Unlocked Mode, Locked Mode Vandal Proof

Page 6

STOPPER INSTALLATION PROCEDURE

The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be removed) or “Unlock” Mode (Stopper is removable).

Locked Mode:

Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper. Fig. G.

To install the stopper in “Locked” mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the Sink and the American Standard logo is facing front. Rotate

Stopper slightly if necessary so that the Stopper slides all the way down.Fig. G.

Re-install the Cam into the Drain, rotating the Cam if necessary to make sure it is fully inserted. Fig. J.

Re-install the Cam Cap, making sure the guide teeth are facing outward. If the Cam Cap does not “snap” into place, then rotate the Cam to make sure it is fully inserted. Fig. K.

Fig. G.

LOGO

LOOP TOWARD

REAR OF SINK

DRAIN

Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in Troubling Shooting Guide to complete installation. Stopper will be in “Locked” mode and not be removable.

Unlocked Mode:

Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper. Fig. H.

To install the stopper in “Unlocked” mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the

Sink and the American Standard logo is facing rear. Rotate Stopper slightly if necessary so that the Stopper slides all the way down.

Fig. H.

Re-install the Cam into the Drain, rotating the Cam if necessary to make sure it is fully inserted. Fig. J.

Re-install the Cam Cap, making sure the guide teeth are facing outward. If the Cam Cap does not “snap” into place, then rotate the Cam to make sure it is fully inserted. Fig. K.

Locked Mode

(Vandal Proof)

Fig. H.

LOGO

180˚

LOOP TOWARD

FRONT OF SINK

DRAIN

Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in “Troublingshooting Guide” to complete installation. Stopper will be in “Unlocked” mode and removable.

Unlocked Mode

Fig. J.

CAM

Fig. K.

INSTALL CAM

INSTALL CAM CAP

M 9 6 5 2 2 7

6

Image 6
Contents Monoblock Lavatory Installation Instructions QUENTIN7440.101Install Faucet Faucet with Speed Connect DrainRemove Flange Install POP-UP DrainInstall Drain from Tighten Locknut Below Fixture Flange Gasket and POP-UP KnobAttach Cable Connector Check Operation of POP-UPMake Water Supply and Waste Connections With Handle 1 in OFF position, turn on Water Test Installed FittingService Caution Check Drain ConnectionsFollow Cable Adjustment Procedure Troubleshooting GuideCable Adjustment Procedure Follow Stopper Removal ProcedureUnlocked Mode Locked Mode Vandal Proof7440.101 Model Number