Siemens MG-2D manual Three-way conference 444-101-200, User 555 is not able to Place a call

Page 12

Three-way conference

444<->101<->200

Conference View for 444

User 444 has set up a 3-way con- ference between 444, 101 and 200.

User 444 is not able to set

up any additional call

Context View for 444

The phone offers no option to add an additional participant to the conference as the maxi- mum number of local confer- ence participants is exceeded.

User 555 is not able to

place a call.

Context View for 555

The phone blocks any other call attempts from different users until the resources are available again.

Multi Address Appearance on OpenStage

00.00.2007 I 12

Image 12
Contents Technical Paper Siemens Enterprise CommunicationsDisclaimer DisambiguationMulti Address Appearance on OpenStage Contents Scope Line OpenStage Primary appearance Secondary appearanceOpenStage Phone Line Primary appearance Secondary appearance Functional Overview MotivationUser Experience Basic RepresentationPrimary line Secondary lineLine Overview Making Calls with Multiple Lines Incoming CallMaking calls Incoming Call PresentationIdle line PrimaryLast NoneUser 444 is not able to set Up any additional call Three-way conference 444-101-200User 555 is not able to Place a call Conference View forUser Interface Examples Call Options in the Context Menu Call Context MenuLine Overview Tab Call Context MenuLED Status Overview User Configuration Items Line Configuration MenuUser Configuration Keyset Lines UserOverview Configuration Menu User Configuration Keyset OverviewOverview Configuration Overview screen can be configAdministrative Options WBM ConfigurationAdmin System Features -Keyset operation General Keyset OptionsMulti Address Appearance on OpenStage System Features Program keys Preview Line PreviewFPK line key programming FPK programming Line key options per FPKData required Multi Address Appearance on OpenStage Limitations ReferencesAbbreviations Siemens Enterprise Communications GmbH & Co. KG