Siemens S50037 manual Multi-Slave Operation, Writing to SieMo, SPI Timing

Page 23

SieMo S50037 Data Book PRELIMINARILY

Multi-Slave Operation

SieMo should not be connected in a multi-slave arrangement by simple parallel connection of slave MISO lines. When SieMo is deselected (SPI_CSB = 1), the SPI_MISO line does not float. Instead, SieMo outputs 0 if the processor is running or 1 if it is stopped.

Writing to SieMo

To write to the SieMo, the 8-bit write command (00000010) is sent first (C[7:0] followed by a 16-bit address (A[15:0]). 16 bits of data (D:[15:0]) are sent.

Terminal

Type

Description

Device

PC Parallel

 

 

 

Terminal

Connector

SPI_CSB

CMOS input

Serial Peripheral Interface Chip

E1

2

 

 

Select

 

 

SPI_CLK

CMOS input

Serial Peripheral Interface SPI

E2

9

 

 

Clock

 

 

SPI_MOSI

CMOS input

Serial Peripheral Interface SPI

E3

8

 

 

Data Input

 

 

SPI_MISO

CMOS output

Serial Peripheral Interface SPI

E4

10

 

 

Data Output

 

 

GND

 

 

B3

19

SPI Timing

figure 22 SPI write operation a

figure 23 SPI write operation b

23/30

Image 23
Contents Data Book Module PSE PRO RCD Author Part of this Document DepartmentReferences Issue Date Reason for ChangesGeneral Information HistoryPin Description Electrical CharacteristicsContent General InformationManufacturing aspects, Handling Regulatory Statements Bluetooth-TrademarkReset Power SupplyAbsolute Maximum Ratings Electrical CharacteristicsTiming Characteristics Terminal CharacteristicsReceiver Min Typ Max Unit Spec Power ConsumptionRadio Characteristics Mode Min Typ Max UnitTransmitter Min Typ Max Unit Spec Output SpectrumModulation Spectrum Spurious emissions on the antenna port Flatness of output power Vs timeOutput spectrum in the whole 2,4 GHz ISM band Max Hold Parameter of the Antenna port VCO SettlingPin description table Pinout DiagramPower Pin DescriptionPIO-Interface USB-InterfacePCM-Interface SPI-Interface15/30 Description Interface DescriptionPCM Interface OverviewPCM Timing PCM clock upper Vs PCM sync in 2 different time-scales Timing graphsRTS/CTS Uart SettingsProperty Possible Values Default Setting Uart Interface20/30 Usbresume Disconnect and Resume SignallingPower Modes USB InterfaceSingle-Cycle Operation USB TimingSerial Peripheral Interface Instruction CycleSPI Timing Terminal Type Description Device PC Parallel ConnectorMulti-Slave Operation Writing to SieMoAuto-Increment Operation Reading from SieMoManufacturing aspects, Handling EN 301 489-17 ETS 300 826 V1.1.1 Regulatory StatementsGeneral European Union EU and Efta Member StatesFCC ID P6L-SieMo-S50037 United States of America USAManufacturer information concerning antenna Bluetooth-Trademark List of figures Appendix a