Operation and Features

SPD’s do not require alot of operator intervention after installation.

NOTE: The PM Series has a green LED for each phase which extinguishes when the module is no longer providing protection (fault condition).

All of the PM series of SPDs contain a diagnostic circuit which monitors the suppressors status continuously and automatically. If a fault condition were to occur, the built-in front panel audible alarm will sound and a red "Service" LED will light, indicating that the unit is in need of service by a qualified technician.

The audible alarm can be silenced by pressing the "Mute Alarm" button on the touchpad, until a qualified electrician or service person is available to service the unit. The red "Service" LED will continue to be illuminated even though the audible alarm has been silenced. This will continue until the fault condition has been cleared.

Each of the internal surge protection modules have a green LED that lights to signify that the module is on-line and functioning properly (the N-G module does not have an LED). In addition to module LED’s, the front panel also dis- plays the status of each internal module by use of diagnostically controlled green LED’s. This technique ensures that a false indication does not occur if an LED were to burn out. A true/hard fault condition can be confirmed by having an audible alarm with the red "Service" LED lit, as well any module LED and front panel status LED extinguished. By utilizing all of these built in diagnostic features, an operator can more easily determine if a hard fault exists or if a status LED is faulty. If power is applied to the SPD and one or more of the module LED’s are extinguished and any diagnostic LED on the front panel concurs with any module LED, then the faulted module may need to be replaced. Use the troubleshooting section of this manual to locate and repair the fault.

Page 9

Image 12
Contents 990-0524 10/00 6XUJH$UUHVWŠ306HULHV Figures Installation TestingIntroduction Unpacking & Preliminary InspectionLocation Considerations EnvironmentAudible Noise Mounting and Cabinet DataService Clearance Product Orientation7DEOH9ROWDJH5DWLQJDQG6HUYLFH7\SHE\0RGHO Voltage Rating0RGHO1XPEHU Terminals7R3URWHFWHG/RDGV 3KD 1HXWUDO 1HXWUDO%XV LI Xvhg Urxqg URXQG%XV$51,1 1875 Disconnect Switch Option DXJKWHUERDUGIRU2SWLRQDO6XUJH&RXQWHU6KRZQLvfrqqhfw 2SWLRQ $51,1 Status Panel Controls, Indicators, and Alarms LJXUH6WDWXV3DQHOZLWK6XUJH&RXQWHU2SWLRQSurge Counter Option Corrective Maintenance Repair Troubleshooting7DEOH5HOD\&RQWDFW3LQ$UUDQJHPHQW Dry Contacts OptionDOO LJXUHLVSOD\%RDUG/RFDWRULDJUDP LVFRQQHFWSRZHUWRWKH63Diagnostic Board Removal and Replacement Instructions Surge Module Removal and Replacement InstructionsLJXUHLDJQRVWLF%RDUG/RFDWRULDJUDP Preventive Maintenance Inspection and Cleaning LJXUH6XUJH0RGXOH5HPRYDODQG5HSODFHPHQWReplacement Parts Listing 7DEOH5HSODFHPHQW3DUWV/LVW9ROWDJH6\VWHP Hvfulswlrq 3DUWRUNVLWK 1XPEHU Limited Warranty Technical Support and Customer ServiceReturn Shipment Address