High Accuracy Power Meter (Option 0019) Requires external USB power sensor.
Conduct precise measurements of CW and digitally modulated transmitters in the field using this VNA Master software mode with a separately purchased Anritsu USB power sensor. After specifying the center frequency and zeroing the sensor to ensure accuracy at low power levels, the software offers intuitive operation for absolute and relative readouts in dBm or Watts. Option 0019 supports the USB Power Sensors in the following table.
USB Power Sensors (Ordered separately):
| PSN50 | MA24104A | MA24106A | MA24108A | MA24118A | |
|
|
|
|
|
| |
Frequency Range | 50 MHz to 6 GHz | 600 MHz to 4 GHz | 50 MHz to 6 GHz | 10 MHz to 8 GHz | 10 MHz to 18 GHz | |
|
|
|
|
|
| |
Description | High Accuracy | Inline | High Accuracy | Microwave | Microwave | |
RF Power Sensor | High Power Sensor | RF Power Sensor | USB Power Sensor | USB Power Sensor | ||
| ||||||
|
|
|
|
|
| |
Connector | Type N, male, 50 Ω | Type N, female, Ω | Type N, male, 50 Ω | Type N, male, 50 Ω | Type N, male, 50 Ω | |
|
|
|
|
|
| |
Dynamic Range | +3 dBm to +51.76 dBm | |||||
(0.001 mW to 100 mW) | (2 mW to 150 W) | (0.1 µW to 200 mW) | (0.1 µW to 100 mW) | (0.1 µW to 100 mW) | ||
| ||||||
|
|
|
|
|
| |
VBW | 100 Hz | 100 Hz | 100 Hz | 50 kHz | 50 kHz | |
|
|
|
|
|
| |
Measurement | ||||||
Burst Average Power | Burst Average power | |||||
|
|
|
| |||
|
|
|
|
|
| |
Measurement Uncertainty | ±0.16 dB1 | ±0.17 dB2 | ±0.16 dB1 | ±0.18 dB3 | ±0.18 dB3 | |
|
|
|
|
|
| |
Datasheet for Additional | ||||||
Specifications | ||||||
|
|
|
|
| ||
|
|
|
|
|
| |
Notes: |
|
|
|
|
|
1)Total RSS measurement uncertainty (0 ºC to 50 ºC) for power measurements of a CW signal greater than
2)Expanded uncertainty with K=2 for power measurements of a CW signal greater than +20 dBm with a matched load. Measurement results referenced to the input side of the sensor.
3)Expanded uncertainty with K=2 for power measurements of a CW signal greater than
Interference Analyzer (Option 0025) (Models MS2036/38C only) (Recommend GPS)
| Spectrum | |
| Field Strength | |
| Occupied Bandwidth | |
| Channel Power | |
| Adjacent Channel Power (ACPR) | |
| AM/FM/SSB Demodulation (Wide/Narrow FM, Upper/Lower SSB), (audio out only) | |
| ||
| Spectrogram (Collect data up to one week) | |
Measurements | Signal Strength (Gives visual and aural indication of signal strength) | |
Received Signal Strength Indicator (RSSI) (collect data up to one week) | ||
| ||
| Gives visual and aural indication of signal strength | |
| Signal ID (up to 12 signals) | |
| Center Frequency | |
| Bandwidth | |
| Signal Type (FM, GSM, | |
| Closest Channel Number | |
| Number of Carriers | |
| ||
|
| |
Application Options | ||
|
|
Channel Scanner (Option 0027) (Models MS2036/38C only)
Number of Channels | 1 to 20 Channels (Power Levels) |
|
|
Measurements | Graph/Table, Max Hold (On/5 sec/Off), Frequency/Channel, Current/Maximum, Dual Color |
|
|
Scanner | Scan Channels, Scan Frequencies, Scan Customer List, Scan Script Master™ |
|
|
Amplitude | Reference Level, Scale |
|
|
Custom Scan | Signal Standard, Channel, # of Channels, Channel Step Size, Custom Scan |
|
|
Frequency Range | 150 kHz to 13 GHz |
|
|
Frequency Accuracy | ± 10 Hz + Time base error |
|
|