Anritsu MS2036C, MS2026C, MS2038C, MS2028C manual Channel Scanner Option 0027 Models MS2036/38C only

Page 15

High Accuracy Power Meter (Option 0019) Requires external USB power sensor.

Conduct precise measurements of CW and digitally modulated transmitters in the field using this VNA Master software mode with a separately purchased Anritsu USB power sensor. After specifying the center frequency and zeroing the sensor to ensure accuracy at low power levels, the software offers intuitive operation for absolute and relative readouts in dBm or Watts. Option 0019 supports the USB Power Sensors in the following table.

USB Power Sensors (Ordered separately):

 

PSN50

MA24104A

MA24106A

MA24108A

MA24118A

 

 

 

 

 

 

Frequency Range

50 MHz to 6 GHz

600 MHz to 4 GHz

50 MHz to 6 GHz

10 MHz to 8 GHz

10 MHz to 18 GHz

 

 

 

 

 

 

Description

High Accuracy

Inline

High Accuracy

Microwave

Microwave

RF Power Sensor

High Power Sensor

RF Power Sensor

USB Power Sensor

USB Power Sensor

 

 

 

 

 

 

 

Connector

Type N, male, 50 Ω

Type N, female, Ω

Type N, male, 50 Ω

Type N, male, 50 Ω

Type N, male, 50 Ω

 

 

 

 

 

 

Dynamic Range

–30 dBm to +20 dBm

+3 dBm to +51.76 dBm

–40 dBm to +23 dBm

–40 dBm to +20 dBm

–40 dBm to +20 dBm

(0.001 mW to 100 mW)

(2 mW to 150 W)

(0.1 µW to 200 mW)

(0.1 µW to 100 mW)

(0.1 µW to 100 mW)

 

 

 

 

 

 

 

VBW

100 Hz

100 Hz

100 Hz

50 kHz

50 kHz

 

 

 

 

 

 

Measurement

True-RMS

True-RMS

True-RMS

True-RMS. Slot Power,

True-RMS, Slot power,

Burst Average Power

Burst Average power

 

 

 

 

 

 

 

 

 

 

Measurement Uncertainty

±0.16 dB1

±0.17 dB2

±0.16 dB1

±0.18 dB3

±0.18 dB3

 

 

 

 

 

 

Datasheet for Additional

11410-00414

11410-00483

11410-00424

11410-00504

11410-00504

Specifications

 

 

 

 

 

 

 

 

 

 

 

Notes:

 

 

 

 

 

1)Total RSS measurement uncertainty (0 ºC to 50 ºC) for power measurements of a CW signal greater than –20 dBm with zero mismatch errors

2)Expanded uncertainty with K=2 for power measurements of a CW signal greater than +20 dBm with a matched load. Measurement results referenced to the input side of the sensor.

3)Expanded uncertainty with K=2 for power measurements of a CW signal greater than –20 dBm with zero mismatch errors

Interference Analyzer (Option 0025) (Models MS2036/38C only) (Recommend GPS)

 

Spectrum

 

Field Strength

 

Occupied Bandwidth

 

Channel Power

 

Adjacent Channel Power (ACPR)

 

AM/FM/SSB Demodulation (Wide/Narrow FM, Upper/Lower SSB), (audio out only)

 

Carrier-to-Interference ratio (C/I)

 

Spectrogram (Collect data up to one week)

Measurements

Signal Strength (Gives visual and aural indication of signal strength)

Received Signal Strength Indicator (RSSI) (collect data up to one week)

 

 

Gives visual and aural indication of signal strength

 

Signal ID (up to 12 signals)

 

Center Frequency

 

Bandwidth

 

Signal Type (FM, GSM, W-CDMA, CDMA, Wi-Fi)

 

Closest Channel Number

 

Number of Carriers

 

Signal-to-Nose Ratio (SNR) > 10 dB

 

 

Application Options

Bias-Tee (On/Off), Impedance (50 Ω, 75 Ω, Other)

 

 

Channel Scanner (Option 0027) (Models MS2036/38C only)

Number of Channels

1 to 20 Channels (Power Levels)

 

 

Measurements

Graph/Table, Max Hold (On/5 sec/Off), Frequency/Channel, Current/Maximum, Dual Color

 

 

Scanner

Scan Channels, Scan Frequencies, Scan Customer List, Scan Script Master™

 

 

Amplitude

Reference Level, Scale

 

 

Custom Scan

Signal Standard, Channel, # of Channels, Channel Step Size, Custom Scan

 

 

Frequency Range

150 kHz to 13 GHz

 

 

Frequency Accuracy

± 10 Hz + Time base error

 

 

Measurement Range

–110 dBm to +30 dBm

 

 

Application Options

Bias-Tee (On/Off), Impedance (50 Ω, 75 Ω, Other)

)

15

Image 15
Contents High Performance Handheld S-Parameters IntroductionVNA Master + Spectrum Analyzer Performance and Functional Highlights VNA MasterVNA Master Functional Specifications 20 dB Frequency Range GHz Directivity dB High Port PowerFrequency Range GHz Typical High Port Power dBm Measurement UncertaintiesLow Port Power High Port Power Frequency Range GHz Typical Low Port Power dBm Amplitude Ranges FrequencyBandwidth Spectral PuritySecond Harmonic Distortion P1dBVNA Performance Capabilities MS202x/3xC + Spectrum Analyzer Performance Capabilities Power Monitor Option 0005 Requires external detector Power Monitor Detectors* Ordered separatelySecure Data Operation Option Internal Voltage/Current Internal Resolution External Voltage/CurrentBias Tee Option Vector Voltmeter OptionChannel Scanner Option 0027 Models MS2036/38C only Distance Domain Option 0501 included in Time Domain Option Balanced/Differential S-Parameters, 1-port OptionVNA Master General Specifications MS202x/3xC Specifications General SpecificationsInput and Output Ports Master Software Tools and Remote Programming Feature BenefitMS202x/3xC Standard Accessories Ordering InformationAncillary Equipment Optional Accessories Part Number Waveguide Calibration Components and WG/ Coaxial AdaptersManuals Related Literature, Application NotesPage Mexico Anritsu Company, S.A. de C.V Anritsu CompanyCanada Brazil