Lightning Audio 7532 manual Selection New point, Store point

Page 63

7532

Commissioning

Function "dip table handl." (036)

– + E

Use this function to enter the dip value (level or distance) which will correct the mea- surement values.

Selection:

new point

edit point

store point

delete point

return

next point

previous point

General procedure:

To enter a new point into the dip table, use "new point" to enter the value (pairs), "store point" to sort the new value (pairs), "return" to go to the dip table mode and "table on" to activate the dip table.

new point

You can enter a new point. A suggested value is displayed for the measured variable, the dip value of the current level or the distance. With semi-automatic inputs, the current level or the current remaining fill height is displayed as proposed dip value. The new value pair can be altered without selecting the

"edit point" parameter.

If the table is full, you can still select this parameter. In this case, the number of free table entries stands at minimum value (= 0).

edit point

The displayed value pair can be changed. Only the dip value can be changed with semi- automatic input mode.

Caution!

To accept the value pair in the table, confirm it with "store point".

store point

The displayed value pair is sorted in the table.

Note!

For sorting, the following criteria must be met:

Measured variables may not be equal but have different dip values.

A measured variable available in the table is recognized as equal when it is closer than 1 mm to the sorting value.

After successful sorting, the setting remains at "edit point" and the number of free table entries is decremented.

Caution!

If the value cannot be sorted, the setting remains at the previous menu option. No warning or error message is generated. However, the number of remaining table entries is not decremented.

63

Image 63
Contents IOM027FVAE0804 Radar Tank GaugeContrast Installation and Operations ManualBrief operating instructions Radar Tank GaugeTable of Contents Designated use Safety InstructionsInstallation, commissioning and operation Operational safetyReturn 7532 Safety InstructionsDirect voltage Device certified for use in explosion hazardous areaExplosion hazardous area Safe area non-explosion hazardous area7532 Identification IdentificationDevice designation Nameplate and Certification PlatesOrdering structure Identification Radar Tank GaugeOrdering structure 7532 RTG 7532 Output and operation CE mark, declaration of conformity Scope of deliveryCertificates and approvals Registered trademarksQuick installation guide Mounting7532 Mounting Storage Incoming acceptance, transport, storageIncoming acceptance TransportDimensions Installation ConditionsEngineering tips Measuring conditionsBehaviour if measuring range is exceeded Measuring range depending on product class for 7532 RTG 7532 Mounting Measuring rangeBlocking distance Mounting Radar Tank Gauge Blocking distanceIt is strongly recommended not to dismantle this antenna Installation instructionsInstallation in stilling well Mounting kit7532 RTG Turn housing Installation tips Installation with Varec UNI flange06-en-002 Pull off housing Mount Varec UNI flange Ansi Mounting with Sample hatch on stilling wellMounting with Pivoting element Post-installation checkWiring Quick wiring guide7532 Wiring 3 4 Wiring Radar Tank GaugeGrounding single sided on Tank Side Monitor 4590 TSM 7532 Wiring Wiring with Tank Side MonitorConnecting the measuring unit Connection to Tank Side Monitor Hart connection with two Varec RN 221 NHart connection with other supplies Post-connection check Equipotential bondingDegree of protection Overvoltage protectorOperation Quick operation guide7532 Operation Typing in numerals and text Selection and configuration in Operation menuOperation Radar Tank Gauge Selection menusIdentifying the functions General structure of the operating menuDisplay and operating elements DisplayLiquid crystal display LCD Light emitting diodes LEDs Display symbolsSymbols Meaning Calibration to regulatory standards disturbedSoftware reliability Custody locking switchKey assignment Function of the keysHardware lock Locking of the configuration modeLocal operation Unlock parameter 0A4Unlocking of configuration mode 555 = History Reset Factory settings ResetUser input reset 0A3 333 = reset customer parametersAlarm / Warning Display and acknowledging error messagesType of error AlarmHart communication Handheld unit DXRToF Tool operating program Operation Radar Tank Gauge Commuwin II-Operating Program ConnectionInterface Hardware Server Device list Page Commissioning Switching on the measuring deviceCommissioning Function checkCommissioning Radar Tank Gauge Basic Setup7532 SetupCommissioning Radar Tank Gauge Stilling well Basic Setup with the VUFunction group basic setup SelectionSelection Unknown Commissioning Radar Tank Gauge Function medium propertySelection Standard 7532 Commissioning Function process condFunction full calibr Commissioning Radar Tank Gauge Function empty calibrFunction dist./ meas. value Function pipe diameterDist. unknown Function range of mapping Display dist./meas.value Function history resetFunction auto-correction Mounting calibration with VUFunction group mounting calibr Function tank gaugingFunction pipe diam. corr 7532 Commissioning Display custody mode 0A9 Active posActive neg Offset Commissioning Radar Tank Gauge Dip tableDisplay Table off Table onTable off Function dip table Semi-automaticClear table ViewStore point Selection New pointPrevious point Commissioning Radar Tank Gauge Delete pointReturn Next pointSingle curve or Function plot settings 09AEnvelope curve with VU Function recording curve 09BBasic Setup /5 Basic Setup with the ToF Tool7532 Commissioning Basic Setup /5 You can also specify the pipe diameter in this display User-specific applications operation Envelope curve with the ToF ToolMounting calibration /2 Mounting calibration with the ToF Tool7532 Commissioning Mounting calibration /2 Page Replacement Maintenance7532 Maintenance Exterior cleaningPage Accessories Page Troubleshooting Troubleshooting instructions7532 Troubleshooting Troubleshooting Radar Tank Gauge Code Description Possible cause Remedy System error messagesCode Description Possible cause Remedy Error Output Application errorsLoss of echo LevelSpare parts 7532 RTG Modification nameplate Spare parts 7532 RTGSoftware changes Documentation changes Date Troubleshooting Radar Tank Gauge Housing T12Disposal Software historyTechnical data Technical data at a glance7532 Technical data According to Oiml R85 Technical dataRadar Tank GaugeOperating conditions EnvironmentProcess conditions Supplementary Documentation Human interfaceAPI American Petroleum Institute XA 081F-AAppendix Operating menu Hart Display modul, ToF Tool7532 Appendix Dome ceiling Unknown Standard Appendix Radar Tank GaugeReturn to Group Selection Operating matrix Hart / Commuwin Operating Matrix Hart / Commuwin Description of functions Function and system design Measuring principleInput Equipment architecture Appendix Radar Tank Gauge OutputStand-alone Integration into the Asset Management System 7532 Appendix On-site operationRemote operation System integration via Rackbus100 Installation and Operations Manual Custody transfer modeParticularities in approved operation Definition of terms101 Integrated on tank gauging system 102 Installation and Operations ManualIndex Radar Tank Gauge IndexIOM027FVAE0804 103 Quick wiring guide 7532 IOM027FVAE0804 105 Radar Tank Gauge Your offical representative

7532 specifications

Lightning Audio 7532 is an innovative car audio amplifier designed to enhance the overall sound experience in vehicles. With a focus on delivering high-quality audio performance, this amplifier stands out with its robust features and cutting-edge technologies.

One of the primary characteristics of the Lightning Audio 7532 is its power output. The amplifier is capable of delivering an impressive 300 watts of RMS power, making it suitable for a wide range of audio systems. This power enables users to drive their speakers and subwoofers with clarity and precision, resulting in a dynamic listening experience. The amplifier has a two-channel configuration, which means it can efficiently amplify signals for front and rear speakers or can be bridged to drive a single subwoofer.

The Lightning Audio 7532 incorporates advanced technologies that enhance its performance. It features a high-pass and low-pass filter, allowing users to customize the audio output according to their preferences. This feature is particularly beneficial for those who wish to tailor their sound system's frequency response to suit different musical genres or personal tastes. Moreover, the amplifier includes a variable gain control, enabling users to adjust the overall volume and maintain optimal sound clarity without distortion.

Another notable aspect of the Lightning Audio 7532 is its thermal protection circuitry. This technology prevents the amplifier from overheating, ensuring reliable performance even during extended periods of use. Additionally, the amplifier is designed with durable components, contributing to its longevity and resilience against the rigors of automotive environments.

The installation process of the Lightning Audio 7532 is simplified by its compact size and user-friendly design. It features a clear layout for terminal connections, allowing for easy wiring and setup. This amplifier can easily fit into tight spaces within a vehicle, making it a versatile option for various car models.

In conclusion, the Lightning Audio 7532 amplifier combines power, flexibility, and durability, making it an excellent choice for car audio enthusiasts. With its impressive specifications and user-centric features, it promises to elevate any audio system and deliver an immersive experience on the road. Whether for everyday driving or long journeys, the Lightning Audio 7532 amplifies sound enjoyment and brings music to life in a way that resonates with every listener.