Alcatel-Lucent 740 manual Site Requirement Guidelines, Environmental Site Requirements

Page 39

Site Requirement Guidelines

SITE REQUIREMENT GUIDELINES

The guidelines in this section help you to maintain and protect your OA-740 and its components from potential damage from over-voltage, extreme temperature conditions, and other adverse conditions. To assure normal operation and avoid unnecessary maintenance, plan your site configuration and prepare your site before installing the OA-740.

Follow these general precautions when planning your equipment locations and connections:

Make sure that the site maintains an ambient temperature between 15°C and 25°C, and keep the area around the system to be clean and dust-free.

Ensure that the cooling vents are not blocked and there is adequate air flow due to ample clearances around the OA-740.

Alcatel-Lucent recommends keeping the OA-740 off the floor and out of any area that tends to collect dust.

Follow ESD prevention procedures to avoid damage to equipment. Damage from static discharge can cause immediate or intermittent equipment failure.

The table below lists the operating and non-operating environmental site requirements. The ranges listed are those within which the OA-740 will continue to operate; however, a measurement that is approaching the minimum or maximum of a range indicates a potential problem. You can maintain normal operation by anticipating and correcting environmental anomalies before they approach minimum or maximum operating range.

Table 18: Environmental Site Requirements

Specification

Minimum

Maximum

 

 

 

Temperature, operating

0°C

45°C

 

 

 

Temperature, non-operating

–25°C

70°C

 

 

 

Humidity (non-condensing), operating

10%

90%

 

 

 

Altitude, operating

Sea level

10,000 ft. (3048 m)

 

 

 

Altitude, non-operating

Sea level

15,000 ft. (4572 m)

 

 

 

Clearance, air intake, and exhaust

20 inches (50.8 cm)

 

 

 

Alcatel-Lucent

OmniAccess 740 Hardware User’s Guide

31

Image 39
Contents West Agoura Road OmniAccess 740 Hardware Users GuideCopyright Preface Starting the OmniAccess List of Figures Page List of Tables Page About this Guide Chapter DescriptionAudience Safety Warnings Document OrganizationDocument Conventions Documentation Feedback Obtaining DocumentationReference Publications Obtaining Technical AssistanceAlcatel-Lucent Introduction OmniAccess 740 OverviewOA-740 Overview Package ContentsOA-740 Hardware OverviewOA-740 Chassis OA-740 ChassisParameter Value OA-740 Chassis Physical SpecificationsFront Panel Slot Numbers LED StatusStatus Description SE LEDs Port or Module Port Type Connect To Cable ConnectionsUser Modules Services EngineLEDs for Ethernet Port on SE Card SE Card LEDsSE Card LEDs Status DescriptionOA7-T1E1-4 Port T1E1 Line Card LEDs T1E1 Card LEDsT1E1 Port LEDs GigE Line Card T1E1 Mode LEDsGigE Line Card LEDs GigE Card LEDsLEDs for each Port on GigE Card LED Interface Serial Line Card V.35/X.21Serial Card V.35/X.21 LEDs Serial Card V.35/X.21 LEDsSerial V.35/X.21 Port LEDs Serial Card V.35/X.21 Cable Part Numbers Serial Card V.35/X.21 Cable DetailsOmniAccess Physical Specifications System SpecificationsEnvironmental Specifications Power SpecificationsInstalling the OmniAccess Preparing for Installation Installation ChecklistRequired Tools and Equipment Preventing Injury Safety MeasuresEquipment Guidelines Lifting Safely Safety with ElectricityPreventing Electrostatic Discharge Damage Specification Minimum Maximum Site Requirement GuidelinesEnvironmental Site Requirements Power Supply Specifications Power Supply OverviewConnecting Power Cord Plant Wiring General Installation RACK-MOUNTING the OA-740 Parts Required Rack Mounting the OA-740 Installing the OA-740IN the RackInstalling Line Cards Installing User ModulesInstalling Fillers Installing Line CardStarting the OmniAccess Starting the OA-740 Checking Conditions Prior to System StartupStarting the OA-740 Connecting to the System Console Port RJ-45 ConnectorRJ-45 Console Port Console Properties Accessing OA-740 Through CLI Performing Basic Configuration TasksEnable secretpassword 5 password Interface name slot/port Http enabledisable ALUconfig# write mem Connecting to Internal Network Connecting the System to the NetworkOmniAccess Connecting Through SSH RJ-11 Modem Port Connector Connecting Through External NetworkSite LOG Alcatel-Lucent Declaration of Conformity CE Mark Appendix a Regulatory Compliance and Safety InformationWaste Electrical and Electronic Equipment Weee Statement China Rohs Hazardous Substance Table 产品说明书附件Cbfb Safety Standards ComplianceTelecom Manufacturer’s Address Declaration of Conformity AddendumApplication of Council Directives Manufacturer’s NameFCC Class A, Part CISPR22 Class a Warning Canada Class a StatementClass a Warning for Taiwan and Other Chinese Markets Translated Safety Warnings Translated Safety Warnings Battery Warning Español FrançaisRead Important Safety Information Warning Wrist Strap Warning Instrucciones DE Seguridad EN Español Cumple con 21CFR 1040.10 y 1040.11 ó sus equivalentes Alcatel-Lucent Output AC Power Supply SpecificationsDescription Specification Input Environmental CharacteristicsDescription Specification Regulatory compliance RJ-11 Connector Pin Number Signal Name RJ-11 Modem Connector PIN AssignmentsRJ-45 Connector Pin # Signal Name RJ-45 Console Connector PIN AssignmentsT1E1 Connector PIN Assignments T1E1 Card Port Connector Pin AssignmentPin # Signal Name Pin # 10 Base-T and 100 Base-Tx 1000 Base-Tx Mode SE/L2GE Connector PIN AssignmentsPin# Signal Name Serial Card V.35/X.21 Connector PIN AssignmentsPORT1TXCB P2P3CMODE2 Serial Card V.35 DTE Cable Pin-out

740 specifications

The Alcatel-Lucent 740, also known as the 7400 Series, is a high-performance, versatile platform designed for service providers looking to deliver a wide range of services, including broadband and voice over IP (VoIP). This system is engineered to support the growing demand for bandwidth and the shift towards more data-centric services, catering to both residential and business users.

One of the standout features of the Alcatel-Lucent 740 is its ability to provide advanced routing capabilities. With its robust routing engine, the platform can handle complex tasks such as traffic management and Quality of Service (QoS) optimization. This ensures that the user's experience remains consistent and high quality, even during peak usage times. The precise routing capabilities are critical for applications that require low latency and high reliability, such as video conferencing and online gaming.

The 7400 Series also integrates seamlessly with existing networks, supporting both legacy and modern protocols. This ensures that service providers can transition smoothly to new technologies without losing compatibility with older systems. The platform supports various technologies, including MPLS (Multiprotocol Label Switching), which aids in efficient data traffic handling and improves network performance.

Another important characteristic of the Alcatel-Lucent 740 is its scalability. As service demands grow, the platform can be easily expanded to accommodate increased traffic and new services. This adaptability ensures that providers can invest in their infrastructure with confidence, knowing that the 7400 Series will grow alongside their business needs.

Additionally, the Alcatel-Lucent 740 supports various access technologies, including DSL, fiber optics, and wireless, allowing service providers to offer a range of options to their customers. This flexibility is particularly valuable as it enables providers to tailor their services to the specific needs of different markets.

Furthermore, the platform features an intuitive management interface that simplifies network maintenance and operations. This reduces the operational burden on service providers, allowing them to focus on delivering exceptional service rather than getting bogged down by complex technical challenges.

In conclusion, the Alcatel-Lucent 740 delivers a powerful combination of advanced routing, scalability, and multi-technology support, making it a compelling choice for service providers looking to enhance their service offerings in today's competitive landscape.