RACK-MOUNTING THE OA-740

The OA-740 is mounted on a standard 19-inch equipment rack. To easily access the electrical cables while the system is installed in a rack, ensure that you have easy access to the front and rear of the system, and that there is about 20-inch clearance at the front and rear of the rack.

You can also mount the OA-740 on an equipment shelf provided that the rack dimensions allow you to secure the system to the shelf. However, Alcatel-Lucent recommends rack-mounting the OA-740.

To rack-mount the OA-740, consider the following guidelines:

Maximum recommended operating temperature

The maximum recommended operating temperature for the OA-740, indoor is 45°C. Determine a suitable operating environment based on this recommendation.

Elevated operating ambient temperature

If the unit is installed in a closed or multi-unit rack assembly, the operating temperature of the rack environment may be greater than the ambient temperature of the room. Keep this in mind when installing the OA-740.

Reduced Airflow

Install the OA-740 shelf in the rack so that the amount of airflow required for safe operation of the equipment in not compromised.

Mechanical Loading

Mount the OA-740 in the rack so as to avoid a potentially hazardous condition due to uneven mechanical loading.

Circuit Overloading

When you connect the OA-740 to the supply circuit, consider the effect that overloading of the circuits might have on over current protection and supply wiring.

Reliable Grounding

Maintain reliable grounding for the OA-740 and all rack-mounted equipment, giving particular attention to supply circuits.

Note: Alcatel-Lucent strongly recommends that you provide a ground connection to the OA-740.

Alcatel-Lucent

36

OmniAccess 740 Hardware User’s Guide

Image 44
Contents OmniAccess 740 Hardware Users Guide West Agoura RoadCopyright Preface Starting the OmniAccess List of Figures Page List of Tables Page Audience About this GuideChapter Description Document Conventions Safety WarningsDocument Organization Obtaining Documentation Reference PublicationsObtaining Technical Assistance Documentation FeedbackAlcatel-Lucent OmniAccess 740 Overview IntroductionPackage Contents OA-740 OverviewHardware Overview OA-740OA-740 Chassis OA-740 ChassisOA-740 Chassis Physical Specifications Parameter ValueFront Panel Status Description SE LEDs Slot NumbersLED Status Cable Connections Port or Module Port Type Connect ToServices Engine User ModulesSE Card LEDs SE Card LEDsStatus Description LEDs for Ethernet Port on SE CardOA7-T1E1-4 T1E1 Port LEDs Port T1E1 Line Card LEDsT1E1 Card LEDs T1E1 Mode LEDs GigE Line CardLEDs for each Port on GigE Card GigE Line Card LEDsGigE Card LEDs LED Serial Line Card V.35/X.21 InterfaceSerial V.35/X.21 Port LEDs Serial Card V.35/X.21 LEDsSerial Card V.35/X.21 LEDs Serial Card V.35/X.21 Cable Details Serial Card V.35/X.21 Cable Part NumbersOmniAccess System Specifications Environmental SpecificationsPower Specifications Physical SpecificationsInstalling the OmniAccess Required Tools and Equipment Preparing for InstallationInstallation Checklist Safety Measures Preventing InjuryEquipment Guidelines Safety with Electricity Lifting SafelyPreventing Electrostatic Discharge Damage Environmental Site Requirements Specification Minimum MaximumSite Requirement Guidelines Power Supply Overview Power Supply SpecificationsConnecting Power Cord Plant Wiring General Installation RACK-MOUNTING the OA-740 Parts Required Installing the OA-740IN the Rack Rack Mounting the OA-740Installing User Modules Installing Line CardsInstalling Line Card Installing FillersStarting the OmniAccess Checking Conditions Prior to System Startup Starting the OA-740Starting the OA-740 RJ-45 Console Port Connecting to the System Console PortRJ-45 Connector Console Properties Performing Basic Configuration Tasks Accessing OA-740 Through CLIEnable secretpassword 5 password Interface name slot/port Http enabledisable ALUconfig# write mem Connecting the System to the Network Connecting to Internal NetworkOmniAccess Connecting Through SSH Connecting Through External Network RJ-11 Modem Port ConnectorSite LOG Alcatel-Lucent Appendix a Regulatory Compliance and Safety Information Declaration of Conformity CE MarkWaste Electrical and Electronic Equipment Weee Statement 产品说明书附件 China Rohs Hazardous Substance TableCbfb Telecom SafetyStandards Compliance Declaration of Conformity Addendum Application of Council DirectivesManufacturer’s Name Manufacturer’s AddressFCC Class A, Part Canada Class a Statement CISPR22 Class a WarningClass a Warning for Taiwan and Other Chinese Markets Translated Safety Warnings Translated Safety Warnings Battery Warning Français EspañolRead Important Safety Information Warning Wrist Strap Warning Instrucciones DE Seguridad EN Español Cumple con 21CFR 1040.10 y 1040.11 ó sus equivalentes Alcatel-Lucent AC Power Supply Specifications Description Specification InputEnvironmental Characteristics OutputDescription Specification Regulatory compliance RJ-11 Modem Connector PIN Assignments RJ-11 Connector Pin Number Signal NameRJ-45 Console Connector PIN Assignments RJ-45 Connector Pin # Signal NamePin # Signal Name T1E1 Connector PIN AssignmentsT1E1 Card Port Connector Pin Assignment SE/L2GE Connector PIN Assignments Pin # 10 Base-T and 100 Base-Tx 1000 Base-Tx ModeSerial Card V.35/X.21 Connector PIN Assignments Pin# Signal NamePORT1TXCB P2P3CMODE2 Serial Card V.35 DTE Cable Pin-out

740 specifications

The Alcatel-Lucent 740, also known as the 7400 Series, is a high-performance, versatile platform designed for service providers looking to deliver a wide range of services, including broadband and voice over IP (VoIP). This system is engineered to support the growing demand for bandwidth and the shift towards more data-centric services, catering to both residential and business users.

One of the standout features of the Alcatel-Lucent 740 is its ability to provide advanced routing capabilities. With its robust routing engine, the platform can handle complex tasks such as traffic management and Quality of Service (QoS) optimization. This ensures that the user's experience remains consistent and high quality, even during peak usage times. The precise routing capabilities are critical for applications that require low latency and high reliability, such as video conferencing and online gaming.

The 7400 Series also integrates seamlessly with existing networks, supporting both legacy and modern protocols. This ensures that service providers can transition smoothly to new technologies without losing compatibility with older systems. The platform supports various technologies, including MPLS (Multiprotocol Label Switching), which aids in efficient data traffic handling and improves network performance.

Another important characteristic of the Alcatel-Lucent 740 is its scalability. As service demands grow, the platform can be easily expanded to accommodate increased traffic and new services. This adaptability ensures that providers can invest in their infrastructure with confidence, knowing that the 7400 Series will grow alongside their business needs.

Additionally, the Alcatel-Lucent 740 supports various access technologies, including DSL, fiber optics, and wireless, allowing service providers to offer a range of options to their customers. This flexibility is particularly valuable as it enables providers to tailor their services to the specific needs of different markets.

Furthermore, the platform features an intuitive management interface that simplifies network maintenance and operations. This reduces the operational burden on service providers, allowing them to focus on delivering exceptional service rather than getting bogged down by complex technical challenges.

In conclusion, the Alcatel-Lucent 740 delivers a powerful combination of advanced routing, scalability, and multi-technology support, making it a compelling choice for service providers looking to enhance their service offerings in today's competitive landscape.