Allied Telesis AT-PWR03 Hub or Layer 2 Switch, Browse to the GUI, Log in and set the password

Page 17

AR750S-DP Secure VPN Router

To connect via a LAN, use an Ethernet cable to connect the router’s switch port(s) to the device(s) on the LAN. Select the LAN PC from which you wish to configure the router. The PC should be in the same subnet as the part of the LAN that contains the router (for example, the PC could be connected to a hub or Layer 2 switch that is directly connected to one of the router’s switch ports).

Hub or Layer 2 Switch

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10BASE-T/100BASE-TX SWITCH PORTS

 

 

 

 

 

 

 

 

 

 

4

3

2

1

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

PC

POWER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AR750S-DP Router

 

 

 

 

 

 

 

 

 

 

 

AR750S-DPSecure VPN Router

 

 

 

 

 

 

ETHERNET

 

SWITCH PORTS

 

CONSOLE

 

 

 

 

 

 

 

1

 

2

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PIC1

 

STATUS

ETHERNET

 

SWITCH PORTS

 

PIC

 

 

 

 

 

 

 

PSU 2

 

 

 

 

 

1

 

 

 

 

 

 

 

RESET PSU 1

SYS

0 1

1

2 3 4

5

0

0

 

1

3

5

ASYN0

PIC0

 

 

 

 

 

 

 

 

PIC BAYS

 

 

 

 

 

 

 

Switch Ports

750S-DP_Hub

 

 

 

 

 

 

 

 

 

 

 

 

 

2.Assign the PC an IP address in the same subnet as the router.

The router’s default IP address is 192.168.1.1, and the default subnet mask is 255.255.255.0.

3.Browse to the GUI.

If you access the Internet through a proxy server, set your browser to bypass the proxy for 192.168.1.1. Point your web browser at 192.168.1.1.

4.Log in and set the password.

At the login prompt, enter the login name and password. Passwords are case sensitive.

User Name: manager

Password: friend

The system status page appears and you can now use the GUI to configure the router.

Important To ensure configuration settings are saved correctly, use the GUI menus and buttons to navigate, not your browser’s buttons.

16

Image 17
Contents Installation and Safety Guide Installation and Safety Guide Page Table of Contents Models Covered By This Guide Package ContentsSelecting a Site Installing the RouterAT-PWR03 AC PSU package contents Installing PICs Before installingInstalling the Router in a Rack Installing the Router on a Level Surface DC power supply specifications Using an AT-PWR03Power Supply PSUAC power supply specifications Insert the power supply unit into the router Installing the Power SupplyUnpack the power supply unit For an AT-PWR03 AC power supply Applying Power to the Power SupplyFor an AT-PWR03 DC power supply Secure the power supply unitSecure the cable Check that the power supply and cable is not livePlug the supply cable into the router Connect the cable to the circuit breaker Power the routerChecking the PSU’s status Remove the PSU Removing a Power SupplyDisconnect the power to the PSU Configure with the Graphical User Interface GUI Configuring the RouterConnect the PC to a router switch port Switch PortsBrowse to the GUI Hub or Layer 2 SwitchLog in and set the password Customise the router for your region Change the default IP addressTo access context-sensitive help in the GUI Asyn0 Port Configure with the Command Line Interface CLIInitiate router start-up Save the configuration Use the CLI to continue configuring the router AR750S-DP Default ConfigurationConnecting the router to your network Connecting Data Cables to the AR750S-DPConnecting to the LAN Connecting a DMZLED LEDs on the AR750S-DPState Function SYSDocumentation and Tools CD-ROM Category Approval Agency and Requirement Emission Compliance StatementsElectrical Notices SafetyLightning Danger Lightning Activity Electrical Type Class 1 EquipmentGefahr Durch Blitzschlag SicherheitAchtung Gefährliche Spannung Vorsicht Rahmeneinbau VorsichtNetzsicherung Elektriske Forholdsregler SikkerhedFare Under Uvejr LynaktivitetELEKTRISK-OVERBELASTNING AF Spændingskredsløbet Elektrisk Klasse 1-UDSTYRWaarschuwingen MET Betrekking TOT Elektriciteit VeiligheidGevaar Voor Blikseminslag Elektrische Toestellen VAN KlasseInstallation and Safety Guide Information SUR LES Risques Électriques SécuritéAvertissement Danger D’ÉLECTROCUTION Équipement DE Classe 1 ÉlectriqueInstallation and Safety Guide Salamaniskuvaara TurvallisuusSähköön Liittyviä Huomautuksia Page Pericolo DI Fulmini Norme di SicurezzaAvvertenze Elettriche Page Elektrisitet SikkerhetFare for Lynnedslag Elektrisk Type 1- Klasse UtstyrInstallation and Safety Guide Avisos Sobre Características Elétricas SegurançaAtenção Perigo DE Choque Elétrico Perigo DE Choque Causado POR RaioPage Avisos Electricos SeguridadPeligro DE Rayos Temperatura Requerida Para LA OperaciónInstallation and Safety Guide Tillkännagivanden Beträffande Elektricitetsrisk SäkerhetFara FÖR Blixtnedslag Elektriskt TYP Klass 1 UtrustningInstallation and Safety Guide Telecommunications Interfaces Important Safety InstructionsConnection to mains voltage supply TNV1 Connection to Isdn networkPorts for the connection of other apparatus For the AR021U PIC US Federal Communications Commission FCCRJ49C Allied Telesis International North Creek Parkway #200Canadian Department of Communications
Related manuals
Manual 31 pages 44.01 Kb

AT-PWR03, AR750S-DP specifications

The Allied Telesis AR750S-DP and AR44xS are robust and innovative networking solutions designed to meet the demands of modern enterprises. These devices are designed for performance, scalability, and flexibility, making them ideal for various applications, including data centers, enterprise campus networks, and service provider environments.

The AR750S-DP is a 10GbE (Gigabit Ethernet) routing platform that offers exceptional performance. It features a Dual Power supply option for added reliability, ensuring continuous network operations even in the event of a power failure. This router is equipped with a high-performance CPU and supports advanced routing protocols, making it suitable for both IPv4 and IPv6 environments. The device encompasses features like Quality of Service (QoS), which prioritizes critical applications and ensures optimal bandwidth allocation.

Alongside the AR750S-DP, the AR44xS series serves as a versatile edge router, offering similar performance characteristics. Designed for high-speed broadband access, the AR44xS is particularly effective in delivering reliable internet services. It comes equipped with advanced security features, including embedded firewalls and VPN support, enabling secure remote access and protecting sensitive information from potential threats.

Both models leverage Allied Telesis' innovative technology known as "Multi-layer Switching," which enhances the performance and efficiency of networks by allowing simultaneous data processing at various layers of the OSI model. Additionally, these devices support Layer 3 routing, enabling intelligent traffic management and optimizing data flow across the network.

The AR750S-DP and AR44xS also feature management capabilities that simplify network configuration and monitoring. With support for SNMP (Simple Network Management Protocol), network administrators can easily manage and diagnose network issues, ensuring high availability and performance.

Incorporating Advanced Layer 2 and Layer 3 features, both models facilitate seamless integration into existing network infrastructures, providing scalability that meets the growing demands of businesses. The user-friendly web interface simplifies setup and provides real-time monitoring tools that enhance operational efficiency.

In summary, the Allied Telesis AR750S-DP and AR44xS are advanced networking devices tailored for organizations seeking high-performance, reliable, and secure solutions. With cutting-edge features and comprehensive management capabilities, these routers cater to the diverse needs of modern connectivity, ensuring businesses can thrive in an increasingly digital world.