Allied Telesis AR415S Connection to Isdn network, Ports for the connection of other apparatus

Page 39

38

AR400 Series Router

Connection to ISDN network

This product is supplied with an approved patch cord for connection to the ISDN Basic Rate Network.

Ports for the connection of other apparatus

The following interfaces normally operate at Safe Extra Low Voltage (SELV) levels:

asynchronous (console) ports

Ethernet ports

G703 ports

synchronous ports

Note SELV is a secondary circuit whose voltages do not exceed a safe value under normal operating conditions and under single fault conditions. Under normal operating conditions the voltages do not exceed 42.4 V peak AC or 60 V DC.

TNV1

The following interfaces are Telecommunications Network Voltage (TNV1) circuits, which operate normally within the limits of SELV:

BRI ports for connection to ISDN Basic Rate telecommunications networks

PRI ports for connection to ISDN Primary Rate telecommunications networks

E1/T1 ports for connection to E1/T1 services

Note A TNV1 circuit is a circuit which under normal operating conditions does not exceed the limits for SELV and on which overvoltages from telecommunication networks are possible.

TNV3

The following interface is a Telecommunications Network Voltage (TNV3) circuit, which operates normally in excess of the limits of SELV:

xDSL ports for connection to xDSL services

Note A TNV3 circuit is a circuit which under normal operating conditions exceed the limits for SELV and on which overvoltages from telecommunication networks are possible.

613-000313 Rev D

Image 39
Contents Installation and Safety Guide AR415S AR440S AR441S AR442S AR450S Installation and Safety GuideAR400 Series Router Table of Contents Models Covered By This Guide Package ContentsInstallation and Safety Guide AR440S, AR441S and AR442S Selecting a Site Installing the AR415SBefore Installing the Router AR415S RouterRmount Check the supply voltage and the router’s rated voltage Applying Power to the RouterConfiguring the AR415S Using the CLI to configure the AR415SInitiate router start-up AR400 Series Router Log in and set the passwordConfigure the router Save the configurationRouter Using the GUI to configure the AR415SConnect the PC to a router switch port Access the CLI on the routerEnable IP Assign an IP address to VLAN1Browse to the GUI Connect to the WAN Connecting Data Cables to AR415SConnecting the router to your network Connect to the LANSystem LEDs on AR415S LEDState Function AR440S, AR441S, AR442S Routers Installing the AR440S, AR441S, AR442SInstalling an Optional PIC Installing the Router in a Rack Installing the Router on a Wall Applying Power to the Router Using the GUI to configure the AR440S, AR441S and AR442S Configuring the AR440S, AR441S, AR442SSwitch Ports Hub or Layer 2 SwitchRouter Log Installation and Safety Guide Set PC to automatic IP addressAdvanced configuration Using the CLI to configure the router At the log in prompt, enter the login name and password Connecting Data Cables to AR440S, AR441S, AR442S System LEDs on AR440S, AR441S, AR442S AdslShdsl AR450S Router Installing the AR450SInstalling the Router in a Rack Using the CLI to configure the AR450S Configuring the AR450SLog in and set the password Using the GUI to configure the AR450S Enable IP Connect to the DMZ port Connecting Data Cables to the AR450SSystem LEDs on the AR450S Default Configuration on AR440S, AR441S, AR442S Documentation and Tools CD-ROM Important Safety Instructions Connection to mains voltage supplyTelecommunications Interfaces TNV3 Connection to Isdn networkPorts for the connection of other apparatus TNV1Lightning Activity Electrical Type Class 1 Equipment SafetyElectrical Notices Lightning DangerVorsicht SicherheitAchtung Gefährliche Spannung Gefahr Durch BlitzschlagLynaktivitet Elektrisk Klasse 1-UDSTYR SikkerhedElektriske Forholdsregler Fare Under UvejrElektrische Toestellen VAN Klasse VeiligheidWaarschuwingen MET Betrekking TOT Elektriciteit Gevaar Voor BlikseminslagÉquipement DE Classe 1 Électrique SécuritéInformation SUR LES Risques Électriques Avertissement Danger D’ÉLECTROCUTIONTurvallisuus Sähköön Liittyviä HuomautuksiaSalamaniskuvaara Norme di Sicurezza Avvertenze ElettrichePericolo DI Fulmini Elektrisk Type 1- Klasse Utstyr SikkerhetElektrisitet Fare for LynnedslagPerigo DE Choque Causado POR Raio SegurançaAvisos Sobre Características Elétricas Atenção Perigo DE Choque ElétricoTemperatura Requerida Para LA Operación SeguridadAvisos Electricos Peligro DE RayosElektriskt TYP Klass 1 Utrustning SäkerhetTillkännagivanden Beträffande Elektricitetsrisk Fara FÖR BlixtnedslagRJ11C For the AR021U PICRJ49C For the AR440S and AR442S routersCanadian Department of Communications Category Approval Agency and Requirement Emission Compliance StatementsStandards The AR450S meets the following standards
Related manuals
Manual 53 pages 24.96 Kb Manual 6 pages 33.2 Kb Manual 11 pages 31.94 Kb

AR440S, AR442S, AR415S, AR441S, AR450S specifications

Allied Telesis offers a range of advanced routers designed to meet the connectivity and operational needs of modern enterprises. Among its extensive lineup, the AR450S, AR441S, AR415S, AR442S, and AR440S models stand out for their robust features and technologies, making them ideal solutions for various networking environments.

The Allied Telesis AR450S is a high-performance router tailored for service providers and large enterprises. It supports advanced routing protocols, including IPv4 and IPv6, ensuring compatibility with both legacy and modern networks. The AR450S boasts substantial throughput capabilities, making it suitable for bandwidth-intensive applications. Its versatile WAN options, including Ethernet and cellular connectivity, allow seamless integration into diverse network architectures.

Next in the lineup is the AR441S, which focuses on providing enhanced security and reliability. With built-in firewall capabilities and VPN support, this model ensures secure communication over the internet. The AR441S also features numerous Ethernet ports for flexible connectivity, enabling organizations to scale their networks as needed. Its user-friendly interface facilitates straightforward configuration and management.

The AR415S is designed for branch offices and small to medium-sized enterprises. This router offers a balance of performance and affordability, equipped with essential features like Quality of Service (QoS) and traffic shaping. The AR415S supports multiple WAN connections, which helps in maintaining reliable internet access by auto-failing to backup connections when necessary.

The AR442S incorporates advanced networking technologies, including dynamic routing protocols and deep packet inspection. This model enhances performance by optimizing traffic flow and improving bandwidth utilization. Its support for VoIP and other multimedia applications makes it an excellent choice for organizations seeking to maximize their communication capabilities.

Lastly, the AR440S is engineered for high availability and redundancy. It includes dual power supplies and hot-swappable components, ensuring that network services remain uninterrupted during maintenance. The AR440S is particularly valuable in mission-critical environments where downtime can lead to significant business disruption.

In summary, the Allied Telesis AR series routers—AR450S, AR441S, AR415S, AR442S, and AR440S—offer a rich set of features tailored to various operational needs. With their advanced routing capabilities, security features, and reliable performance, these routers represent the cutting edge of networking technology for businesses looking to enhance their connectivity and operational efficiency.