AR400 Series Router

6.Mount the router in the rack.

Use appropriate rack mounting screws (not supplied).

Applying Power to the Router

1.Check the supply voltage and the router’s rated voltage.

AR400 Series routers are fitted with a universal mains power supply that will function over the range 100 VAC to 240 VAC and 50 Hz to 60 Hz.

For continued protection against the risk of fire and shock hazard, replace fuses only with the same type and rating.

Warning The specific power supply requirements for a particular model are clearly displayed on the rear or underside of the router. If the supply is outside the accepted range for the router, the router may not operate or damage to the router may result.

2.Fit the power cord retaining clip to the AC power inlet on the router’s rear panel.

3.Connect the provided power cord to the AC power inlet and clip it in place. Switch the router’s power switch to the ON position. The Power LED lights continuously and the System LED lights briefly. The Port LEDs also light briefly.

The router is supplied with an approved power cord that incorporates a moulded plug. It must only be used with the power cord supplied.

If the LEDs fail to light, the most likely cause is that the router is not receiving power. Check that:

the power supply outlet’s switch (if any), and the router’s power switch, are in the ON position

the power cable is securely plugged in

the power supply is operational

613-000313 Rev D

Image 9
Contents Installation and Safety Guide AR415S AR440S AR441S AR442S AR450S Installation and Safety GuideAR400 Series Router Table of Contents Models Covered By This Guide Package ContentsInstallation and Safety Guide AR440S, AR441S and AR442S Before Installing the Router Installing the AR415SAR415S Router Selecting a SiteRmount Check the supply voltage and the router’s rated voltage Applying Power to the RouterConfiguring the AR415S Using the CLI to configure the AR415SInitiate router start-up Configure the router Log in and set the passwordSave the configuration AR400 Series RouterConnect the PC to a router switch port Using the GUI to configure the AR415SAccess the CLI on the router RouterEnable IP Assign an IP address to VLAN1Browse to the GUI Connecting the router to your network Connecting Data Cables to AR415SConnect to the LAN Connect to the WANSystem LEDs on AR415S LEDState Function AR440S, AR441S, AR442S Routers Installing the AR440S, AR441S, AR442SInstalling an Optional PIC Installing the Router in a Rack Installing the Router on a Wall Applying Power to the Router Using the GUI to configure the AR440S, AR441S and AR442S Configuring the AR440S, AR441S, AR442SSwitch Ports Hub or Layer 2 SwitchRouter Log Installation and Safety Guide Set PC to automatic IP addressAdvanced configuration Using the CLI to configure the router At the log in prompt, enter the login name and password Connecting Data Cables to AR440S, AR441S, AR442S System LEDs on AR440S, AR441S, AR442S AdslShdsl AR450S Router Installing the AR450SInstalling the Router in a Rack Using the CLI to configure the AR450S Configuring the AR450SLog in and set the password Using the GUI to configure the AR450S Enable IP Connect to the DMZ port Connecting Data Cables to the AR450SSystem LEDs on the AR450S Default Configuration on AR440S, AR441S, AR442S Documentation and Tools CD-ROM Important Safety Instructions Connection to mains voltage supplyTelecommunications Interfaces Ports for the connection of other apparatus Connection to Isdn networkTNV1 TNV3Electrical Notices SafetyLightning Danger Lightning Activity Electrical Type Class 1 EquipmentAchtung Gefährliche Spannung SicherheitGefahr Durch Blitzschlag VorsichtElektriske Forholdsregler SikkerhedFare Under Uvejr Lynaktivitet Elektrisk Klasse 1-UDSTYRWaarschuwingen MET Betrekking TOT Elektriciteit VeiligheidGevaar Voor Blikseminslag Elektrische Toestellen VAN KlasseInformation SUR LES Risques Électriques SécuritéAvertissement Danger D’ÉLECTROCUTION Équipement DE Classe 1 ÉlectriqueTurvallisuus Sähköön Liittyviä HuomautuksiaSalamaniskuvaara Norme di Sicurezza Avvertenze ElettrichePericolo DI Fulmini Elektrisitet SikkerhetFare for Lynnedslag Elektrisk Type 1- Klasse UtstyrAvisos Sobre Características Elétricas SegurançaAtenção Perigo DE Choque Elétrico Perigo DE Choque Causado POR RaioAvisos Electricos SeguridadPeligro DE Rayos Temperatura Requerida Para LA OperaciónTillkännagivanden Beträffande Elektricitetsrisk SäkerhetFara FÖR Blixtnedslag Elektriskt TYP Klass 1 UtrustningRJ49C For the AR021U PICFor the AR440S and AR442S routers RJ11CCanadian Department of Communications Category Approval Agency and Requirement Emission Compliance StatementsStandards The AR450S meets the following standards
Related manuals
Manual 53 pages 24.96 Kb Manual 6 pages 33.2 Kb Manual 11 pages 31.94 Kb

AR440S, AR442S, AR415S, AR441S, AR450S specifications

Allied Telesis offers a range of advanced routers designed to meet the connectivity and operational needs of modern enterprises. Among its extensive lineup, the AR450S, AR441S, AR415S, AR442S, and AR440S models stand out for their robust features and technologies, making them ideal solutions for various networking environments.

The Allied Telesis AR450S is a high-performance router tailored for service providers and large enterprises. It supports advanced routing protocols, including IPv4 and IPv6, ensuring compatibility with both legacy and modern networks. The AR450S boasts substantial throughput capabilities, making it suitable for bandwidth-intensive applications. Its versatile WAN options, including Ethernet and cellular connectivity, allow seamless integration into diverse network architectures.

Next in the lineup is the AR441S, which focuses on providing enhanced security and reliability. With built-in firewall capabilities and VPN support, this model ensures secure communication over the internet. The AR441S also features numerous Ethernet ports for flexible connectivity, enabling organizations to scale their networks as needed. Its user-friendly interface facilitates straightforward configuration and management.

The AR415S is designed for branch offices and small to medium-sized enterprises. This router offers a balance of performance and affordability, equipped with essential features like Quality of Service (QoS) and traffic shaping. The AR415S supports multiple WAN connections, which helps in maintaining reliable internet access by auto-failing to backup connections when necessary.

The AR442S incorporates advanced networking technologies, including dynamic routing protocols and deep packet inspection. This model enhances performance by optimizing traffic flow and improving bandwidth utilization. Its support for VoIP and other multimedia applications makes it an excellent choice for organizations seeking to maximize their communication capabilities.

Lastly, the AR440S is engineered for high availability and redundancy. It includes dual power supplies and hot-swappable components, ensuring that network services remain uninterrupted during maintenance. The AR440S is particularly valuable in mission-critical environments where downtime can lead to significant business disruption.

In summary, the Allied Telesis AR series routers—AR450S, AR441S, AR415S, AR442S, and AR440S—offer a rich set of features tailored to various operational needs. With their advanced routing capabilities, security features, and reliable performance, these routers represent the cutting edge of networking technology for businesses looking to enhance their connectivity and operational efficiency.