Xilinx v1.00a specifications PLB Data, Slave Control Bus

Page 7

R

ChipScope PLBv46 IBA (Bus Analyzer) (v1.00a)

Table 2: IBA_PLBv46 Design Parameters (Continued)

Generic

Feature/Description

Parameter Name

Allowable Values

Default

VHDL

Value

Type

 

 

 

 

 

 

 

 

 

 

G30

0=basic, 1=basic w/ edges,

C_MU_3_TYPE_ADDR

0,1,2,3,4,5

0

Integer

 

2=extended, 3= extended w/edges,

 

 

 

 

 

4=range, 5=range w/edges

 

 

 

 

 

 

 

 

 

 

G31

Match unit counter width. 0 means do not

C_MU_3_CNT_W_ADDR

0,1-32

0

Integer

 

use

 

 

 

 

 

 

 

 

 

 

G32

1=Enable storing MU 3 signals in the data

C_MU_3_EN_STORE_ADDR

0,1

1

Integer

 

sample storage buffer.

 

 

 

 

 

0=Disable

 

 

 

 

 

C_USE_MU_3A_ABUS or must

 

 

 

 

 

C_USE_MU_3B_UABUS be 1 in order to

 

 

 

 

 

store.

 

 

 

 

 

 

 

 

 

 

 

 

PLB Data

 

 

 

 

 

 

 

 

 

G33

Use PLB_wrDBus

C_USE_MU_4_WR_DBUS

1,0

0

Integer

 

 

 

 

 

 

G34

0=basic, 1=basic w/ edges,

C_MU_4_TYPE_WR_DBUS

0,1,2,3,4,5

0

Integer

 

2=extended, 3= extended w/edges,

 

 

 

 

 

4=range, 5=range w/edges

 

 

 

 

 

 

 

 

 

 

G35

Match unit counter width. 0 means do not

C_MU_4_CNT_W_WR_DBUS

0,1-32

0

Integer

 

use.

 

 

 

 

 

 

 

 

 

 

G36

1=Enable storing MU 4 signals in the data

C_MU_4_EN_STORE_WR_

0,1

1

Integer

 

sample storage buffer.

DBUS

 

 

 

 

0=Disable

 

 

 

 

 

C_USE_MU_4_WR_DBUS must be 1 in

 

 

 

 

 

order to store.

 

 

 

 

 

 

 

 

 

 

G37

Use PLB_srdDBus

C_USE_MU_5_RD_DBUS

1,0

1

Integer

 

 

 

 

 

 

G38

0=basic, 1=basic w/ edges,

C_MU_5_TYPE_RD_BUS

0,1,2,3,4,5

0

Integer

 

2=extended, 3= extended w/edges,

 

 

 

 

 

4=range, 5=range w/edges

 

 

 

 

 

 

 

 

 

 

G39

Match unit counter width. 0 means do not

C_MU_5_CNT_W_RD_DBUS

0,1-32

0

Integer

 

use

 

 

 

 

 

 

 

 

 

 

G40

1=Enable storing MU 5 signals in the data

C_MU_5_EN_STORE_RD_

0,1

1

Integer

 

sample storage buffer.

DBUS

 

 

 

 

0=Disable

 

 

 

 

 

C_USE_MU_5_RD_DBUS must be 1 in

 

 

 

 

 

order to store.

 

 

 

 

 

 

 

 

 

 

 

 

Slave Control Bus

 

 

 

 

 

 

 

 

 

G41

Use Slave Congrol signals

C_USE_MU_6A_SLV_CTL

1,0

0

Integer

 

 

 

 

 

 

G42

USE SI_rdWdAddr and SI_SSize

C_USE_MU_6B_SLV_SZ_

1,0

0

Integer

 

 

WADDR

 

 

 

 

 

 

 

 

 

G43

Number of match units to use

C_MU_6_NUM_SLV_CTL_

1,2

0

Integer

 

 

BUS

 

 

 

 

 

 

 

 

 

G44

0=basic, 1=basic w/ edges

C_MU_6_TYPE_SLV_CTL_

0,1

0

Integer

 

 

BUS

 

 

 

 

 

 

 

 

 

G45

Match unit counter width. 0 means do not

C_MU_6_CNT_W_SLV_CTL_

0,1-32

0

Integer

 

use

BUS

 

 

 

 

 

 

 

 

 

DS619 (v1.0) September 17, 2007

www.xilinx.com

Product Specification

7

Image 7
Contents Introduction FeaturesCommon Signals ChipScope PLB46 IBA I/O SignalsPort Signal Name Interface Description Reset & Error StatusSlave PLB Arbitration SignalsAddress DataMBE0 CPLBV46NUMMASTERS PLB Master SignalsCPLBV46NUMMASTERS*4-1 CPLBV46NUMMASTERS*3-1Value Type ChipScope PLB46 IBA ParametersPLB Address Trigger In, PLB Reset, and PLB Error StatusIBA Storage Options and Trig Out PLB Grouped Control BusSlave Control Bus PLB DataSlave Busy Status Slave Read/Writer Error StatusPLB Arbitration Value Type PLB Master Control Bus PLB Master Byte EnablePLB Master Size and Type Status Target Technology ChipScope PLB46 IBA Module Block Diagram RestrictionsDesign Implementation Allowable Parameter Combinations