GAS LINE INSTALLATION

When purging gas line the front glass must be removed.

The gas pipeline can be brought in through the right side, left side of the appliance as well as the bottom. Knockouts are provided at convenient locations to allow for the gas pipe installation and testing of any gas connection. It is most convenient to bring the gas line in from the right side, as this allows fan installation or removal without disconnecting the gas line.

The gas line connection can be made with properly tinned 3/8" copper tubing, 3/8" rigid pipe or an approved flex connector.

Always check for gas leaks with a mild soap and water solution. Do not use an open flame for leak testing.

The gas control is equipped with a captured screw type pressure test point, therefore it is not necessary to provide a 1/8" test point up stream of the control.

1/2" Gas Supply

1/2" X 3/8" Reducer

3/8" Nipple

3/8" X 3/8" Shut Off Valve

3/8" Nipple

3/8" Union

TYPICAL GAS LINE CONNECTION 3/8" Nipple

Fig. 7

When using copper or flex connector use only approved fittings. Always provide a union so that gas line can be easily disconnected for burner or fan servicing. See Fig. 7. See gas specification for pressure details and ratings.

The fireplace valve must not be subjected to any test pressures exceeding 1/2 psi. Isolate or disconnect this or any other gas appliance control from the gas line when pressure testing.

- 7 -

REMOTE SWITCH INSTALLATION

FOR RN/RP

1.Thread wire through the electrical knockout located on either side of fireplace.. Do not cut wire or insulation on metal edges. Ensure that wire is protected. Run the other end to a conveniently located wall receptacle box.

2.Attach wire to switch and install switch into receptacle box. Attach cover plate to switch.

3.Connect wiring to gas valve. (Fig. 8)

 

VALVE

 

THERMOPILE

TPTH

 

 

TP

 

 

TH

 

 

 

P

 

I

 

TOL

 

ON/OFF SWITCH

 

 

Fig. 8

ALTERNATE SWITCH LOCATION:

Remote switch can be installed on either side of the access door. Simply mount the switch to the switch bracket provided. Screw the bracket on either side of the frame, lining up the screws with the pre-punched holes. (Fig. 9)

Fig. 9

DO NOT WIRE MILLIVOLT REMOTE WALL SWITCH FOR GAS FIREPLACE TO A 120V POWER SUPPLY.

FOR LIGHTING INSTRUCTIONS PLEASE REFER TO LIGHTING INSTRUCTION PAGE

Page 7
Image 7
Vermont Casting DBR33, DBR39, DBR36 installation instructions GAS Line Installation, Remote Switch Installation For RN/RP