TROUBLE SHOOTING THE GAS CONTROL SYSTEM

HONEYWELL MILLIVOLT VALVE

START

GAS SUPPLY ON

YES

PILOT LIGHTS WITH PIEZO IGNITOR

 

 

 

 

 

CHECK

NO

 

 

 

• SUPPLY LINE HOOKED UP

 

 

 

 

 

 

 

• SHUTOFF VALVE OPEN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• LOCKOUT HAS ENGAGED. WAIT

 

 

 

 

 

60 SECONDS AND TRY AGAIN.

 

 

 

 

 

• PIEZO NOT TIGHT ENOUGH

 

 

 

 

 

FOR GOOD GROUND.

 

 

 

 

 

• FOR SPARK AT ELECTRODE

NO

 

 

 

 

WHILE DEPRESSING PIEZO

 

 

(RED BUTTON) — 1/8" GAP TO

 

 

 

 

 

 

 

 

 

 

PILOT HOOD NEEDED.

 

 

 

 

 

• ALL WIRING CONNECTIONS

 

 

 

 

 

• REPLACE PIEZO IGNITOR

 

 

 

 

 

• THERMODISK

YES

PILOT STAYS LIT

YES

PILOT LIGHTS MAIN

BURNER

YES

NO

NO

FOR AIR IN THE LINES

THERMOPILE NEEDS A MINIMUM 325mV. ADJUST PILOT FLAME HEIGHT.

ALL WIRING CONNECTIONS.

REPLACE THERMOPILE

THERMOCOUPLE NEEDS A MINIMUM OF 14mV.

DEFECTIVE VALVE. TURN TO PILOT, METER SHOULD READ GREATER THAN 100 mV. IF NOT, REPLACE.

THERMODISK

WALL SWITCH IS NOT

TURNED ON. WATCH FOR GROUNDED WIRES!

•THERMOPILE NEEDS A MINIMUM 325mV.

• PLUGGED BURNER ORIFICE.

SYSTEM OK.

- 23 -

Page 23
Image 23
Vermont Casting DBR36, DBR39, DBR33 installation instructions Honeywell Millivolt Valve