TROUBLE SHOOTING THE GAS CONTROL SYSTEM

TROUBLE SHOOTING THE GAS CONTROL SYSTEM

SIT 820 NOVA MILLIVOLT VALVE

GLASS DOOR TO BE REMOVED BEFORE SERVICE WORK

START

GAS SUPPLY ON

CHECK

NO

 

• SHUTOFF VALVE OPEN

 

 

• CONFIRM GAS HOOK-UP

 

 

LIGHT PILOT WITH

PIEZO IGNITION

YES

NO

ELECTRODE GAP MIN. 1/8"

ELECTRODE CRACKED

ELECTRODE CABLE ATTACHED

PIEZO IGNITOR GENERATES SPARK

ELECTRODE CABLE NOT GROUNDED

PILOT STAYS ON

YES

NO

FLAME ENGULFING THERMOCOUPLE BY 3/8"

THERMOCOUPLE ATTACHED TO VALVE

MNIMUM MILLIVOLT:

OPEN CIRCUIT 18MV

CLOSED CIRCUIT 5MV

VENT SAFETY SWITCH TIGHT AND NO SHORTS

(FOR UNITS EQUIPPED WITH VENT SAFETY SWITCH)

MAIN BURNER ON

NO

REMOTE SYSTEM ON

REMOTE SYSTEM WIRE SHORTING OUT

MINIMUM MILLIVOLT: OPEN CIRCUIT 300MV CLOSED CIRCUIT 165MV

FLAME ENGULFING THERMOPILE/THERMOCOUPLE

VALVE IS IN ON POSITION

- 22 -