Vermont Casting DBR39 Gas Inlet & Manifold Pressures, Final Finishing, Hearth, Gas Specifications

Models: DBR36 DBR33 DBR39

1 32
Download 32 pages 15.6 Kb
Page 6
Image 6
FINAL FINISHING

FINAL FINISHING

Non-combustible materials such as brick and tile can be extended over the outer face of the unit (Do not cover louvres or glass door). If a Trim Kit is going to be installed, brick and tile will have to be installed flush with the side of this appliance.

HEARTH

A hearth is not mandatory but it is recommended for aesthetic purposes. We recommend a non-combustible hearth which does not obstruct louvre opening.

Cold climate installation recommendation: When installing this unit against a non- insulated exterior wall or chase, it is mandatory that the outer walls be insulated to conform to applicable insulation codes.

GAS SPECIFICATIONS

 

 

 

MAX.

MIN.

 

 

 

INPUT

INPUT

MODEL

FUEL

GAS CONTROL

B.T.U.H

B.T.U.H.

DBR33 RN

Natural Gas

Millivolt Hi/Lo

15,000

10,500

DBR33 RP

Propane Gas

Millivolt Hi/Lo

15,000

11,250

DBR36 RN

Natural Gas

Millivolt Hi/Lo

18,000

12,600

DBR36 RP

Propane Gas

Millivolt Hi/Lo

18,000

13,500

DBR39 RN

Natural Gas

Millivolt Hi/Lo

22,000

15,400

DBR39 RP

Propane Gas

Millivolt Hi/Lo

22,000

16,500

 

 

 

 

 

 

 

 

 

Table 6

GAS INLET & MANIFOLD PRESSURES

 

NATURAL

LP (Propane)

Input Minimum
4.5" wc
11" wc
Input Maximum
7" wc
13" wc
Manifold Pressure
3.5" wc
10" wc

 

 

Table 7

CERTIFIED TO:

ANSI Z1.88b-1999/CSA Z2.33-M-99 harmonized, standard for Vented Gas Fireplace.

Do not use this fireplace if any part of it has been under water. Immediately call a qualified service technician to inspect the fireplace and replace any part of the control which has been under water.

The installation of your Fireplace must conform with local codes, or in the absence of local codes, with National Fuel Gas Code, ANSI Z223.1 — latest edition, or CAN 1 B1-

149.1and .2 Installation Code. (EXCEPTION: Do not derate this appliance for altitude. Maintain the manifold pressure at 3.5 inches W.C. for Natural Gas and 10 inches W.C. for LP gas.)