EAW KF730, SB730 owner manual Stacking Additional Enclosures Fly-Bar as the base

Page 24

6.8.5Stacking Additional Enclosures (Fly-Bar as the base)

CAUTION: When attaching Hinges to Hinge Tubes in step 5 for an SB730, position the SB730 so it lies flat on the SB730 below it. In step 5 for a KF730, use the correct holes as determined by the KF730 Wizard or by the user-desired angles to achieve the desired splay angle. Failure to follow this instruction can result in poor acoustical performance.

1.Lift an SB730 or KF730 from its pallet and turn it upside down, so the Hinges on the enclosure are on the bottom.

2.Lift the enclosure onto the stack mating the alignment pads and recesses between them.

3.Remove the four Quick Release Pins from the Hinges of the upper enclosure.

4.If they do not drop from gravity, slide the four Hinges on the upper enclosure down into the Hinge Tubes on the enclosure below it.

5.Attach each Hinge to the Hinge Tube by inserting a Quick Release Pin (removed in Step 9) through both.

6.For a KF730, use its handles to lift the rear of the enclosure as far as possible and insert a Quick Release Pin (removed in step 2) into each of the enclosure’s rear Hinge Tubes as a locking pin. See “Locking Pins” Section 6.4.5.

7.Repeat steps 1 to 6 for additional enclosures.

Page 24 of 28 RD0169 (A) KF730 & SB730 OWNER’S MANUAL

Image 24
Contents KF730 & SB730 Loudspeaker EAW Part RD0169Page Table of Contents Safety Precautions General PrecautionsRead this First EC Statement of ConformityContents IntroductionUnpacking Shipping DamageKF730 Array Design Fill CoverageGround Stacking SubwoofersSignal Delay on Subwoofers Other SubwoofersSystem Block Diagram Signal ProcessingArray Operation OverviewAmplifier Gain Settings User AdjustmentsAmplifier Power Requirements Selecting an Appropriate Amplifier Size KF730 QtyInput Connections Selecting an Appropriate Amplifier Size Rule Of ThumbOperating Limits 1 KF730 Input Connections2 SB730 Connections 3 SB730 System Input ConnectionsWire Gauge 4 KF730P Input Connections+ -- + 5 SB730P Input ConnectionsRigging Rigging WarningsSuspension Load Rating Working Load Limit WLL FLY-BAR Rigging Recommendations Attaching Enclosures to the FLY-BARQuick Release Pins Hinge and Hinge Tube HolesLocking Pins KF730 and SB730 Hinge and Hinge Tube HolesPallets Initial Rigging PreparationSuspension Procedures 1 KF730s On KF730 Pallet2 SB730s on SB730 Pallet Attaching a KF730 or SB730 to the Fly-BarAttaching SB730s to SB730s Already Suspended Attaching a KF730 to an SB730 Already SuspendedAttaching KF730s to KF730s Already Suspended Ground Stacking Procedures Setting the Tilt Angle for the Entire ArrayStacking With SB730s as the Base Stacking Additional Enclosures SB730 as the base Stacking With the Fly-Bar as the BaseStacking the First Enclosure Fly-Bar as the base Stacking Additional Enclosures Fly-Bar as the base Service Information Literature and SpecificationsContacting EAW Operating QuestionsService and Maintenance General ServiceRigging Service Basic Field TroubleshootingMaintenance Eastern Acoustic Works ONE Main Street WHITINSVILLE, MA