SCANNER OPERATION

POWER SAVE MODES

The MS2421/MS2422 bar code scanners have five configurable power save modes. Refer to the MetroSelect Configuration Guide for additional information on Power Save Modes.

1.Blink Power Save Mode:

Blinks the laser OFF & ON after a configured period of non-use. When the scanner recognizes a bar code it will exit the Blink mode.

2.Laser Off Power Save Mode:

Turns the laser OFF after a configured period of non-use. The motor continues to spin allowing for a faster “wake” up time.

Any movement detected by the photocell will “wake” the scanner from the Laser Off power save mode (see Figure 29 on page 27).

3.Laser & Motor Off Power Save Mode:

Turns the laser and motor OFF after a configured period of non-use.

Any movement detected by the photocell will “wake” the scanner from the power save mode (see Figure 29 on page 27). This mode’s “wake” time is slightly longer due to the motor’s need to restart.

4.Dual Action Power Save Mode #1:

“Blinks” the laser OFF & ON after a configured period of non-use turns the laser and motor OFF at thirty-minute intervals.

Example:

If the power save timeout is set to 15 minutes.

Any movement detected by the photocell will “wake” the scanner from the power save mode (see Figure 29 on page 27).

5.Dual Action Power Save Mode #2 (Default):

Turns the laser OFF after a configured period of non-use then turns the motor OFF after thirty-minute intervals.

Example:

If the power save timeout is set to 15 minutes.

Any movement detected by the photocell will “wake” the scanner from the power save mode (see Figure 29 on page 27).

34

Image 38
Contents Metrologic INSTRUMENTS, INC Copyright TrademarksTable of Contents EMC Product Overview IntroductionManual Scope Description Optional AccessoriesBase KIT Components Replacement Parts General Precautions See caution statement onMS2421 / MS2422 Scanner Design Specifications Design Specifications OperationalBase Model Characteristics MS2421 ScannerDimensions MS2421 Label Locations Top and Examples Bottom MS2422 Scanner MS2422 Dimensions MS2422 Label Locations Top and Examples Bottom Site Requirements InstallationQuick Installation Outline Unpacking the Unit Installing the Unit in the Counter MS2422 Mounting Diagram Cable Installation Interface Specific RS232RS232 Interface Cable Installation Schematic Full Speed USB USB Cable Installation Schematic IBM IBM Cable Installation Schematic Cable Installation Secondary Metrologic Scanner Secondary Scanner Cable Installation Schematic Base Model Checkpoint Recommended Switch Bank Settings EAS DeactivationScanner Operation Scan ZoneHorizontal Direct 13 mil Wake Activation Area Photocell LED Output Wake Activation Area Sensitivity Photocell LED Output Range One Beep Three Beeps on power upAudible Razzberry ToneBlue LED Off Visual Steady BlueSteady Blue and Single blue Flash Flashing BlueDiagnostic Indicator Display Error Code Display Optional Product Roll Bar ShownScanner Operation Scanner Operation Laser & Motor Off Power Save Mode Blink Power Save ModeLaser Off Power Save Mode Dual Action Power Save Mode #1Waking the Unit from All Power Save Modes Changing the Beeper VolumePlacing the Unit in Laser & Motor Off Power Save Mode Beeper Options and Button FunctionsStartup POWER-UP Test ModeConfiguration Mode Maintenance Horizontal Scan Window ReplacementDaily Maintenance Troubleshooting Same symbol timeout isScanner and the communication port match and the program is RS232 Demonstration Program On Error GotoPrint Error NO. ERR Press ANY KEY to Terminate Close SystemDefault Settings Communication ParametersIBM 46 USB IBM USB ACK / NAK Multiple Selections Default Settings Default settings for Aux interface Scanner and Cable Terminations EASSIG2 Scale Ready MS2421 Models Additional Pinout ConnectionsSIG1 SIG3Cable Connector Configurations PC+5V USBPinFunction† ITE Equipment SafetyRegulatory Compliance LaserFunkstöreigenschaften nach EN550221998 RemarqueEuropean Standard Standard EuropeoClass B Devices AvertissementLimited Warranty Metrologic Instruments, IncPatents Index 39, 46, 4739-41 Page Page January 2009, Version