INTRODUCTION
MS2421 / MS2422 SCANNER DESIGN SPECIFICATIONS
|
|
|
|
|
| Design Specifications |
| ||
| Operational |
|
|
|
|
|
|
|
|
| Light Source: | VLD 650 nm |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| Peak Laser Power: | <1.5 mW |
|
|
|
|
|
| |
|
|
|
|
|
|
|
| ||
| Horizontal Depth of Field: | 0 mm - 152 mm (0”- 6”) for 0.33 mm (13 mil) Bar Code |
| ||||||
|
|
|
|
|
|
|
| ||
| Vertical Depth of Field: | 0 mm - 216 mm (0”- 8.5”) for 0.33 mm (13 mil) Bar Code |
| ||||||
|
|
|
|
|
|
|
|
| |
| Scan Speed: | 5400 Scan Lines per Second |
|
|
|
| |||
|
|
|
|
|
|
|
|
| |
| No. of Scan Lines: | 54 (38 Horizontal / 16 Vertical) |
|
|
|
| |||
|
|
|
|
|
|
|
|
| |
| Motor Speed: | 6000 / 6000 RPM (Horizontal / Vertical ) |
|
|
|
| |||
|
|
|
|
|
|
|
|
| |
| Min Bar Width: | 0.127 mm (5.0 mil) |
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| Scan Zone: | 360° |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| Decode Capability: | All Standard | |||||||
|
|
|
|
|
|
|
| ||
| System Interfaces: | RS232, Aux RS232, IBM468x/469x, and USB |
| ||||||
|
|
|
|
|
|
|
|
| |
| Print Contrast: | 35% Minimum Reflectance Difference |
|
|
|
| |||
|
|
|
|
|
|
|
| ||
| No. Characters Read: | Up to 80 data characters. Maximum number will vary based on symbology and density. | |||||||
|
|
|
|
|
|
|
|
| |
| Beeper Operation: | 7 Tones or No Beep; 3 Volume Settings |
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| Indicators (LED): | Blue |
| Laser ON, Ready to Scan |
|
|
|
| |
|
|
|
|
|
|
|
|
| |
| Blue flash |
| Good Read, Decoding |
|
|
|
| ||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| Mechanical |
|
|
|
|
|
|
|
|
| MS2421 L x W x H: | 399 mm (15.7") Length |
| 292 mm (11.5") Width | 130 mm (5.12") Tower Height | ||||
|
|
|
|
|
|
|
| ||
| MS2422 L x W x H: | 353 mm (13.9") Length |
| 292 mm (11.5") Width | 130 mm (5.12") Tower Height | ||||
|
|
|
|
|
|
|
| ||
| Depth (Below Counter): | 100 mm (3.9"), All Models |
|
|
|
| |||
|
|
|
|
|
| ||||
| Weight (with Platter): | MS2422, 5.98 kg (13.20 lbs.) |
|
| MS2421, 9.28 kg (20.5 lbs.) | ||||
| Electrical |
|
|
|
|
|
|
|
|
| Voltage Supply: | 2.5A @ +5.2V / 0.8A @ +12V |
|
|
|
| |||
| Power: | Operating, 11.9 Watts |
| Standby, 3.25 Watts | |||||
| Current: | Operating, 1.7A @ 5.2V / 0.2A @ 12V |
| Standby, .6A @ 5.2V / 0.07A @ 12V | |||||
Current Limits on Integrated | Do not exceed maximum current of 12V @ 0.7A / 5V @ 0.2A |
| |||||||
| Scale and/or Scale Display: |
| |||||||
|
|
|
|
|
|
|
|
| |
| DC Transformers: | Class I; 5.2VDC @ 2.5A; 12VDC @ 0.8A |
| ||||||
| For Regulatory Compliance Information refer to pages 53 - 55. |
|
|
|
| ||||
| Environmental |
|
|
|
|
|
|
|
|
| Operating Temperature: | 0°C to 40°C (32°F to 104°F) |
|
|
|
| |||
| IP Rating: | IP 55 |
|
|
|
|
|
| |
| Light Levels: | 4842 Lux (450 footcandles) |
|
|
|
| |||
| Storage Temperature: |
|
|
|
| ||||
| Humidity: | 5% to 95% Relative Humidity, |
| ||||||
| Contaminants: | Sealed to resist airborne particulate contaminants. |
| ||||||
| Ventilation: | None Required |
|
|
|
|
Specifications are subject to change without notice.