Metrologic Instruments Hand-Held Scanner user manual Symbology Parameters, RS232 Interface, Code39

Page 6

3.2RS232 Interface

The user can select the desired, flow control, baud rate, parity, and data bits to be used in this output interface.

3.2.1Baud Rate / Parity / Data Bits

The supported baud rate, parity, and data bit are listed below.

Baud Rate : 38400 / 19200 / 9600 / 4800 / 2400 / 1200 / 600 / 300

Parity : None / Even / Odd

Data bit : 8 / 7

3.2.2Flow Control

The user can further configure the flow (handshake) control method to be used. The available options are listed below.

No Flow Control

Scanner Ready : The scanner will activate the RTS signal after power on. After each good read the scanner will then wait for the CTS signal becomes active. The data will not be sent until CTS signal becomes active.

Data Ready : The RTS signal will be activated after each good read. The scanner will then wait for the CTS signal becomes active. The data will not be sent until CTS signal becomes active.

Inverted Data Ready : It is like the Data Ready flow control, but the RTS signal level is inverted.

3.2.3Inter-Character Delay

An inter-character delay of 0 to 255 ms can be configured to match the computer response time. The delay time configured is inserted between transmitting every character. The longer the delay time configured, the slower the transmission speed will be. The inter-character delay is zero by default.

4.Symbology Parameters

This section describes user configurable parameters which are pertaining to barcode symbologies.

4.1Code39

Standard / Full ASCII Code 39: User can choose to read either Standard Code 39 or Full ASCII Code 39 by configuring this parameter.

Start/Stop Transmission: This parameter specifies whether the start/stop characters of Code 39 are included in the data being transmitted.

Checksum Verification: This parameter specifies whether the scanner will perform checksum verification when decoding barcodes. If the checksum is incorrect, the barcode will not be read.

Checksum Transmission: This parameter specifies whether the checksum character are included in the data being transmitted.

4.2Italy / French Pharmacode

For Italy /French Pharmacode, there is always a checksum character included in the barcode. So the checksum verification is always performed when decoding these symbologies. User though can choose whether the checksum character is to be transmitted or not. The start / stop transmission of this code shares the same setting of Code 39.

Checksum Transmission: This parameter specifies whether the checksum character is included in the data being transmitted.

4.3Industrial / Interleave / Matrix 25

Start / Stop Selection: This parameter provides the readability of all 2 of 5 symbology variants. For example, flight tickets actually use an Industrial 25 barcode but with Interleave 25 start / stop. In order to read this barcode, the start / stop selection parameter of Industrial 25 should set to ‘Interleave 25.

Checksum Verification: This parameter specifies whether the scanner will perform checksum verification when decoding barcodes. If the checksum is incorrect, the barcode will not be read.

Checksum Transmission: This parameter specifies whether the checksum character is included in the data being transmitted.

Code Length Qualification: Because of the weak structure of the 2 of 5 codes, a partial scan has a high probability of decoding as a valid but shorter 2 of 5 codes (known as short scan). To prevent this

7 8

Image 6
Contents Pulsar C Table of Contents Introduction General FeaturesIndicator BuzzerScanner Time-out Duration Re-read DelaySupported Symbologies Reading RedundancyOutput Interface Keyboard Wedge InterfaceCode39 Symbology ParametersRS232 Interface Italy / French PharmacodeEAN8 CodabarUpce UpcaCharacter Substitution Data Output FormatPlessey Prefix / Postfix CodeData Editing Additional Fields Total Number of FieldsDividing Data into Fields Field Transmission SequenceDefault Configuring your Pulsar CEnter Configuration Mode List SettingKey Type/Status Setting Numeric ParametersCharacter String Parameters Exit Configuration Mode Metrologic European Offices