CBM1000 Service Manual
l Paper feed failure
Phenomenon | Cause |
|
| Check Method |
| Remedy |
| ||||||
Paper is not fed or | Faulty connection of the | Check connection of the | Connect the | connector | |||||||||
fed irregularly | motor connector |
| motor connector. |
|
|
| correctly. |
|
|
| |||
| Defective motor |
| Measure the | supply | If the supply voltage is | ||||||||
|
|
| voltage with a DC volt- | normal, replace the mo- | |||||||||
|
|
| meter or oscilloscope. | tor. |
|
|
| ||||||
| Faulty DC output volt- | Check | whether | the | Use the | specified | AC | ||||||
| age from the | AC | specified AC adapter is | adapter. |
|
|
| ||||||
| adapter |
| used. |
|
|
|
|
|
|
|
|
| |
| Low DC output voltage | Check | the | DC | voltage | Supply the specified AC | |||||||
| from the AC adapter |
| with a DC voltmeter. | voltage | to | the | AC | ||||||
|
|
|
|
|
|
|
|
|
| adapter. |
|
|
|
| Faulty control PCB assy |
|
|
|
|
|
|
| Replace the control PCB | ||||
|
|
|
|
|
|
|
|
|
| assy. |
|
|
|
| Faulty mounting of the | Check mounting condi- | Mount the platen roller | ||||||||||
| platen roller |
| tion of the platen roller. | properly. |
|
|
| ||||||
| Paper feed failure |
| Check | whether | or | not | Eliminate | unnecessary | |||||
|
|
| the paper is jamming or | paper in the paper path | |||||||||
|
|
| torn and caught in the | and set paper properly. | |||||||||
|
|
| paper path. |
|
|
|
|
|
|
|
| ||
| Foreign substance | in | Remove the gear holder | Eliminate | the foreign | ||||||||
| the gear |
| and check for any for- | substance. |
|
| |||||||
|
|
| eign substance | caught |
|
|
|
| |||||
|
|
| in the gears. |
|
|
|
|
|
|
| |||
| Broken gear |
| Remove the gear holder | If the gear is broken, | |||||||||
|
|
| and | check | for | any | replace it with new one. | ||||||
|
|
| breakage of the gears. |
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
– 21 – | CITIZEN |