Regency U39-LP Aeration Adjustment, Log Set Installation, Embers Embers, U39 with 38,000 Btu/h

Models: U39-NG U39-LP

1 40
Download 40 pages 9.09 Kb
Page 24
Image 24
Embers Embers

INSTALLATION

Caution: Carbon will be produced if the air shutter is closed too much.

Note: Any damage due to carboning re- sulting from improperly setting the aeration controls is NOT cov- ered under warranty.

Note: Aeration Adjustment should only be performed by an authorized Regency Installer at the time of installation or service.

Embers Embers

3)Place Rear Log A)02-65 on the two pins on the rear log support.

AERATION

ADJUSTMENT

The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude.

 

U39 with 38,000 Btu/h

U39-NG

Natural Gas:

1/4" open

U39-LP

Propane:

1/2" open

 

U39 with 30,000 Btu/h

U39-NG

Natural Gas

3/16" open

U39-LP

Propane

3/8" open

The aeration adjustment gears are located on the right side of the burner box and can be accessed from the side or from the front when the louvers are removed.

To adjust the aeration: use the allen key to turn the turning gear which will adjust the air shutter. Open the air shutter for a blue flame or close it for a yellower flame.

Clockwise to open,

counter-clockwise to close.

LOG SET

INSTALLATION

Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation.

The gas log kit contains the following:

a)

02-65

Rear Log

902-267

b)

02-56

Middle Left Log

902-230

c)

02-44

Front Left Log

902-228

d)

02-46

Left Top Log

902-231

e)

02-45

Front Right Log

902-229

f)

02-47

Center Log

902-232

g)

02-48

Middle Right Log

902-226

h)

 

Embers

902-151

i)

 

Lava

902-154

The "02" refer numbers (i.e. 02-65) are molded into the rear of each log.

1)Carefully remove the logs from the box and unwrap them. The logs are fragile, handle with care - do not force into position.

2)Sprinkle the embers on the left and right sides of the firebox base.

A)02-65

Pins on Rear Log Support

4)Place the Middle Left Log B)02-56 on the two pins as shown.

B)02-56

5)Sprinkle some lava rock just in front of B) 02-56 on the burner holes.

B)02-56

lava rock

6)Place Front Left Log C)02-44 onto the 2 front pins as shown.

C)02-44

24

Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove

Page 24
Image 24
Regency U39-LP Aeration Adjustment, Log Set Installation, Embers Embers, U39 with 38,000 Btu/h, U39 with 30,000 Btu/h