INSTALLATION
Caution: Carbon will be produced if the air shutter is closed too much.
Note: Any damage due to carboning re- sulting from improperly setting the aeration controls is NOT cov- ered under warranty.
Note: Aeration Adjustment should only be performed by an authorized Regency Installer at the time of installation or service.
Embers Embers
3)Place Rear Log
AERATION
ADJUSTMENT
The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude.
| U39 with 38,000 Btu/h | |
Natural Gas: | 1/4" open | |
Propane: | 1/2" open | |
| U39 with 30,000 Btu/h | |
Natural Gas | 3/16" open | |
Propane | 3/8" open |
The aeration adjustment gears are located on the right side of the burner box and can be accessed from the side or from the front when the louvers are removed.
To adjust the aeration: use the allen key to turn the turning gear which will adjust the air shutter. Open the air shutter for a blue flame or close it for a yellower flame.
Clockwise to open,
LOG SET
INSTALLATION
Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation.
The gas log kit contains the following:
a) | Rear Log | ||
b) | Middle Left Log | ||
c) | Front Left Log | ||
d) | Left Top Log | ||
e) | Front Right Log | ||
f) | Center Log | ||
g) | Middle Right Log | ||
h) |
| Embers | |
i) |
| Lava |
The "02" refer numbers (i.e.
1)Carefully remove the logs from the box and unwrap them. The logs are fragile, handle with care - do not force into position.
2)Sprinkle the embers on the left and right sides of the firebox base.
A)02-65
Pins on Rear Log Support
4)Place the Middle Left Log
B)02-56
5)Sprinkle some lava rock just in front of B)
lava rock
6)Place Front Left Log
C)02-44
24 | Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove |