Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove
A= | Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm) | H= | Not to be installed above a meter/regulator assembly within (3'/90cm) | EXTERIOR VENT TERMINAL | |
LOCATIONS | |||||
B= | Clearance to window or door that may be opened *(12"/30cm) |
| horizontally from the centerline of the regulator. | ||
|
| ||||
C= | Clearance to permanently closed window *(min. 12"/30cm) | J= | Clearance to service regulator vent outlet *(min. 36"/90cm) |
| |
D= | Vertical clearance to ventilated soffit located above the terminal within a | K= | Clearance to |
| |
| horizontal distance of (24"/60cm) from the centerline of the terminal (min. |
| air inlet to any other appliance *(12"/30cm) |
| |
| 18"/46cm) check with local code. | L= | Clearance to a mechanical air supply inlet *(min. 72"/1.8m) |
| |
E= | Clearance to unventilated soffit (min. 12"/30cm) | M= | **Clearance above paved sidewalk or a paved driveway located on public |
| |
F= | Clearance to outside corner: with AstroCap Termination Cap (min. 6"/ |
| property *(min. 84"/2.1m) |
| |
| 15cm), with | N= | Clearance under veranda, porch, deck, or balcony *(min. 12"/30cm)*** |
| |
G= | Clearance to inside corner: with AstroCap Termination Cap (min. 6"/ |
|
|
| |
| 15cm), with |
|
|
|
Note: * As specified in CGA B149 Installation Code. Note: Local codes or regulations may require different clearances.
**A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.
***Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.