Regency U39-LP, U39-NG installation manual Exterior Vent Terminal

Models: U39-NG U39-LP

1 40
Download 40 pages 9.09 Kb
Page 8
Image 8
EXTERIOR VENT TERMINAL

8

Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove

A=

Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm)

H=

Not to be installed above a meter/regulator assembly within (3'/90cm)

EXTERIOR VENT TERMINAL

LOCATIONS

B=

Clearance to window or door that may be opened *(12"/30cm)

 

horizontally from the centerline of the regulator.

 

 

C=

Clearance to permanently closed window *(min. 12"/30cm)

J=

Clearance to service regulator vent outlet *(min. 36"/90cm)

 

D=

Vertical clearance to ventilated soffit located above the terminal within a

K=

Clearance to non-mechanical air supply inlet to building or the combustion

 

 

horizontal distance of (24"/60cm) from the centerline of the terminal (min.

 

air inlet to any other appliance *(12"/30cm)

 

 

18"/46cm) check with local code.

L=

Clearance to a mechanical air supply inlet *(min. 72"/1.8m)

 

E=

Clearance to unventilated soffit (min. 12"/30cm)

M=

**Clearance above paved sidewalk or a paved driveway located on public

 

F=

Clearance to outside corner: with AstroCap Termination Cap (min. 6"/

 

property *(min. 84"/2.1m)

 

 

15cm), with Dura-Vent termination cap (min. 12"/30cm)

N=

Clearance under veranda, porch, deck, or balcony *(min. 12"/30cm)***

 

G=

Clearance to inside corner: with AstroCap Termination Cap (min. 6"/

 

 

 

 

15cm), with Dura-Vent termination cap (min. 12"/30cm)

 

 

 

Note: * As specified in CGA B149 Installation Code. Note: Local codes or regulations may require different clearances.

**A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.

***Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.