MAINTENANCE

LOG REPLACEMENT

The unit should never be used with broken logs. Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs. The pilot light generates enough heat to burn someone. If for any reason a log should need replacement, you must use the proper replacement log. The position of these logs must be as shown in the diagram under Log Installation.

Note: Improper positioning of logs may create carbon build-up and will al- ter the unit’s performance which is not covered under warranty.

DOOR GASKET

If the door gasket requires replacement use 7/ 8" diameter oval door gasket (Part # 650-920).

LATCH ADJUSTMENT

The door latch may require adjustment as the door gasket material compresses after a few fires and after glass replacement. Turn the adjustable catch to tighten or loosen the latch.

GLASS

REPLACEMENT

Your ULTIMATE stove is supplied with high temperature, 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce. In the event that you break your glass by impact, purchase your replace- ment door from an authorized Regency dealer only, and follow our step-by-step instructions for replacement. The glass is not sold sepa- rately, as it must be properly sealed in the door frame.

Replacement Part #

940-325/P U39 Wraparound Glass

940-322/P U39 Panel Center Glass

940-323/P U39 Panel Side Glass

WARNING: Do not operate appli- ance with glass panels removed, cracked or broken. Replacement of the glass should be done by a li- censed or qualified service person.

Note: Wearing gloves will protect your hands while handling glass.

Panel Glass Replacement

1)Remove the door from the unit and place on a soft surface to prevent scratching.

2)Pull out the door gasket.

3)Remove the nuts holding the glass retainers in place.

4)Remove the glass retainers (sides, top and bottom) and the door catch plate.

5)Replace the glass. The glass must have gasketing around it.

6)Reverse the previous steps, replace the retainers and fasten with the nuts but do not overtighten, as this can break the glass. Note: the door catch plate fits on top of the left side retainer.

7)Put gasket glue on the retainers, but do not put glue on the screws. Replace the door gasket, the two ends butt tight together on the bottom edge of the door.

8)Replace door on the stove and check the seal.

Panel Glass Door Assembly

Wraparound Assembly Door (same glass retainers as the Panel Assembly)

Mitred Glass Replacement

Removing Glass

1)Remove the door from the unit and place on a soft surface to prevent scratching.

2)Pull out the door gasket.

3)Remove the 24 nuts holding the glass retainers in place. Do not remove the nuts underneath the retainers.

4)Remove the door catch plate.

5)Remove glass retainers on sides first (3 each side) then remove two center retain- ers.

Note: Center glass retainers are glued to center glass.

6)Remove glass from extrusions. When re- moving center glass, leave white insula- tion in place.

Installing Glass

1)Install both center and side glass ontoextrusionsas per diagram.

2)Place glass assembly into door frame.

3)Install retainers by placing 1 drop of glue where previously glued and put in place.

4)Install side retainers.

5)Install door catch plate.

6)Install the 24 nuts loosely, do not tighten yet.

30

Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove

Page 30
Image 30
Regency U39-LP, U39-NG installation manual LOG Replacement, Door Gasket, Latch Adjustment, Glass Replacement

U39-NG, U39-LP specifications

The Regency U39-LP and U39-NG are modern gas fireplaces designed to enhance the aesthetic appeal and functionality of any space while delivering exceptional performance. These units are part of Regency's commitment to innovation and sustainability, providing homeowners with an efficient heating solution that seamlessly integrates into various home styles.

One of the standout features of the U39 series is its versatility in fuel options. The U39-LP operates on liquid propane, while the U39-NG utilizes natural gas. This flexibility allows homeowners to choose the best option suited for their existing infrastructure and personal preferences. Both models are designed to deliver efficient heating with an impressive BTU output, ensuring that rooms stay warm and comfortable during colder months.

The U39 series is equipped with cutting-edge technologies, including a state-of-the-art control system that allows users to easily adjust the flame height and heat output. This feature not only enhances user convenience but also promotes energy efficiency by allowing adjustments based on real-time heating needs. The inclusion of an optional remote control further simplifies the operation, enabling users to manage their fireplace from anywhere in the room.

Another remarkable aspect of the Regency U39-LP and U39-NG is the clean, contemporary design. The linear shape and large viewing area provide an unobstructed view of the flames, adding a stunning focal point to any living space. The customizable options for finishes and surround materials mean that homeowners can tailor the fireplace to perfectly match their décor, whether it be modern, traditional, or somewhere in between.

Safety is a top priority for Regency, and the U39 series includes multiple safety features to ensure peace of mind. An integrated safety shut-off system is designed to automatically turn off the unit in case of emergencies, while tempered glass doors protect against accidental burns.

In summary, the Regency U39-LP and U39-NG gas fireplaces embody a blend of functionality, beauty, and safety. With their high thermal efficiency, user-friendly technologies, and elegant design, these fireplaces are an ideal choice for anyone looking to elevate their home heating experience while enjoying the charm of a glowing fire. Whether it's for a cozy gathering with family or a quiet evening alone, the U39 series stands out as a stylish solution with exceptional performance.