INSTALLATION
CONVERSION TO LOWER BTU RATING
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!
kPa). Disconnect piping from valve at pres- sures over 1/2 psig.
The manifold pressure is controlled by a regu- lator built into the gas control, and should be checked at the pressure test point.
Natural Gas Conversion Kit 730-920 Contains:
Qty. Part # Description
1
1
1
Propane Conversion Kit 730-922 Contains:
Qty. Part # Description
1
1
1
Additional Piece (pkg. with unit:
1 | Log Bracket Restrictor |
1)Shut off the gas supply.
2)Open the front door. Carefully remove the logs and lava rock.
3)Remove burner. See diagram below.
6)Remove burner orifice with a 1/2" wrench and discard.
Burner Orifice
7)Reinstall new burner orifice (NG stamped #37 or LP stamped #52) and tighten.
8)Reverse steps 3) and 2).
9)Adjust Vent restrictor setting: To set the Vent restriction as indicated in the diagram, simply loosen the screws and push the vent restrictor plate to the correct position. Tight- en the screws.
Unit | Btu/h | Restrictor Opening | |
U39 | 38,000 | A | |
| 30,000 | B |
Note: To properly check gas pressure, both inlet and manifold pressures should be checked using the valve pressure ports on the valve.
1)Make sure the valve is in the "OFF" position.
2)Loosen the "IN" and/or "OUT" pressure tap(s), turning counterclockwise with a 1/ 8" wide flat screwdriver.
3)Attach manometer to "IN" and/or "OUT" pressure tap(s) using a 5/16" ID hose.
4)Light the pilot and turn the valve to "ON" position. Read manometer.
5)The pressure check should be carried out with the unit burning and the setting should be within the limits specified on the safety label.
6)When finished reading manometer, turn off the gas valve, disconnect the hose and tighten the screw (clockwise) with a 1/8" flat screwdriver. Note: Screw should be snug, but do not over tighten
Valve Description
Note: Use a magnetic type screwdriver if possible.
4)Unscrew the 2 Rear Log Pins and move to the front hole po- sition.
5)Remove Rear Log Bracketandslidethe Log Bracket Re- strictor between the
Rear Log Bracket and the burner, secure with the 2 screws.
Position the Log Bracket Restrictor between
the Rear Log Bracket and the burner.
Vent Restrictor | Vent Restrictor |
setting at High Btu/h | setting at Low Btu/h |
10)Attach the label "This unit has been con- verted to..." on top of the Serial # decal over the higher Btu information.
11)Check for gas leaks.
12)Check inlet and outlet pressures.
13)Check operation of flame control. Check for proper flame appearance and glow on logs.
GAS PIPE PRESSURE
TESTING
The appliance must be isolated from the gas supply piping system by closing its individual manual
1)Gas cock knob
2)Manual high/low adjustment
3)Pilot Adjustment
4)Thermocouple Connection
5)Main Operator
6)Outlet Pressure Tap (Manifold Pressure)
7)Inlet Pressure Tap (Supply Pressure)
8)Pilot Outlet
9)Main Gas Outlet
10)Flange Securing Screw Holes
11)Alternative TC Connection Point
12)Thermoelectric Unit
13)Additional Valve Mounting Hole
Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove | 23 |