INSTALLATION
Horizontal Venting with Two (2) 90o Elbows
One 90o elbow = Two 45o elbows.
| Option |
| V | H + H1 |
| A) | 3' | Min. | 2' Max. |
| B) | 5' | Min. | 3' Max. |
| C) | 8' Min. | 4' Max. |
With these options, maximum total pipe length is 30 feet with minimum of 8 feet total vertical and maximum 4 feet total horizontal.
Please note minimum 1 foot between 90o elbows is required.
Lengths do not include elbow indicated
Vent restrictor position A (fully open), refer to page 11.
Vertical Venting with Two (2) 90o Elbows
One 90o elbow = Two 45o elbows.
Option V | H | V1 | V + V1 |
A)1' Min. 1' Max. 1' Min. 2' Min.
B)1' Min. 2' Max. 2' Min. 3' Min.
C)2' Min. 3' Max. 2' Min. 4' Min.
D)2' Min. 4' Max. 2' Min. 4' Min.
With these options, max. total pipe length is 30 feet with min. of 4 feet total vertical and max. 4 feet total horizontal.
Please note min. 1 foot between 90o elbows is required.
Lengths do not include elbow indicated
Vent restrictor position A (fully open), refer to page 11.