Regency U39-NG Louver Installation, Venting Introduction, Locating Your Ultimate Gas Stove

Models: U39-NG U39-LP

1 40
Download 40 pages 9.09 Kb
Page 7
Image 7
MANUFACTURED MOBILE HOME ADDITIONAL REQUIREMENTS

INSTALLATION

Minimum ceiling

height is 36"/914mm

from top of unit.

MANUFACTURED MOBILE HOME ADDITIONAL REQUIREMENTS

LOUVER

INSTALLATION

1)Attach the top & bottom louvers to the side stove panel using 2 screws per side.

VENTING

INTRODUCTION

The DV Stove Horizontal Vent Kit and the Simpson Dura-Vent Direct Vent System Model DV-GS venting systems, in combination with the ULTIMATE Direct Vent Freestanding Gas Stove, U39-NG, and U39-LP, have been tested and listed as direct vent heater systems by Warnock Hersey. If converting a Class-A Metal Chimney or Masonry Chimney to a Direct Vent system, see instructions on pages 19 to 21.

These units use the "balanced flue" technology Co-Axial system. The inner liner vents products of combustion to the outside while the outer pipe draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney.

Note: These flue pipes must not be con- nected to any other appliance.

1)Ensure that structural members are not cut or weakened during installation.

2)Ensure proper grounding using the #8 ground lug provided.

3)Appliance must be anchored to the floor with the supplied anchoring methods.

LOCATING YOUR

ULTIMATE GAS STOVE

When selecting a location for your stove, ensure that the clearances listed above are met as well as ensuring that there is adequate accessibility for servicing and proper opera- tion.

A)Cross Corner

B)Room Divider

C)Island

D)Flat on Wall

E)Flat on Wall Corner

F)Flush with Wall/ Alcove

For Vent Termination require- ments, see page 8.

COMBUSTION AND VENTILATION AIR

The combustion air from this appliance is drawn from outside the building through the outer flue.

Extra provision for combustion air inside the room is not required.

The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas burning appliance. Each direct vent gas appliance must use it's own separate vent system. Common vent sys- tems are prohibited.

IMPORTANT

Read all instructions carefully before starting the installation. Failure to follow these instruc- tions may create a fire or other safety hazard, and will void the warranty. Be sure to check the venting and clearance to combustible require- ments. Consult your local building codes before beginning installation.

The location of the termination cap must con- form to the requirements in the Exterior Vent Terminal Locations diagram on page 8.

INSTALLATION

PRECAUTIONS

These venting systems are engineered prod- ucts that have been designed and tested for use with the U39-NG, and U39-LP. The warran- ty will be voided and serious fire, health or other safety hazards may result from any of the following actions:

1)Installation of any damaged Direct Vent component

2)UnauthorizedmodificationoftheDirectVent System

3)Installation of any component part not man- ufactured or approved by Simpson Dura-

Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove

7

Page 7
Image 7
Regency U39-NG Louver Installation, Venting Introduction, Locating Your Ultimate Gas Stove, Combustion And Ventilation Air