Mitsubishi Electronics HC6000 user manual To stop projecting

Page 19

Viewing video images (continued)

9.Adjust with the W or X button to get an approximate size.

When the ENTER button is pressed while “ZOOM” is displayed, the adjustment mode is switched between FAST and STEP. When FAST is selected, the speed of zoom controlled by the W or X button becomes fast, and it becomes slow when STEP is selected.

10.Press the LENS SHIFT button. The LENS SHIFT menu appears at the center of the screen.

11.Press the S or T button to adjust the vertical position and W or X button to adjust the horizontal position of the displayed image.

When the projector cannot be positioned perpendicularly to the screen, adjust the projection angle. (See page 10.) Repeat steps 3 to 4 and 8 to 11, if necessary.

To stop projecting:

OFF () button

POWER button

12.Press the POWER button on the projector or the OFF () button on the remote control.

A confirmation message is displayed.

To cancel the procedure, leave the projector for a while or press the MENU button.

13.Press the POWER button on the projector or the OFF () button on the remote control again.

The lamp goes out and the projector goes into a standby mode. In this standby mode, the STATUS indicator blinks green.

14.Wait about 2 minutes.

During this period of 2 minutes in the standby mode, the intake fan and exhaust fan rotate to cool the lamp.

The lamp can’t be lit again for 1 minute after turning off the projector for safety purpose. It will take another 1 minute for the STATUS indicator to go out. If you want to turn on the projector again, wait until the indicator goes out, and then press the POWER button.

The air outlet fans rotate faster as the temperature around the projector rises.

Do not unplug the power cord while the STATUS indicator is blinking. Unplugging the power cord immediately after use may cause a lamp breakdown.

Though the fan makes loud sound during cooling, such symptom is not a malfunction.

15.Unplug the power cord from the outlet.

The POWER indicator will go out.

If the power cord should be unplugged accidentally while either the air inlet fan or the air outlet fans are operating or the lamp is on, allow the projector to cool down for 10 minutes with the power off. To light the lamp again, press the POWER button. If the lamp doesn’t light up immediately, repeat pressing the POWER button two or three times. If it should still fail to light up, replace the lamp.

Cover the lens with the lens cap to protect it from dust.

EN-19

Image 19
Contents HC6000 Risk of Electric Shock Do not Open When using the projector in EuropeContents Important safeguards Important safeguards Inserting the batteries into the remote control Checking accessoriesPreparing your projector Terminal panel Preparing your projectorOverview Control areaBottom side Remote controlUsing the picture quality adjusting buttons Adjustment feetFront of projector Rear of projector Using the remote controlOperational range of the remote control Reception angleLens Shift button Setting up your projectorSetting up the screen Basic setupWhen projected images are distorted to a trapezoid Setting up your projectorAdjusting the projection angle When fine streaks are seen on projected imagesWhen the aspect ratio of the image is When the aspect ratio of the screen isScreen size and projection distance Trigger terminal With the Installation menu See page 26 for menu settingFront projection, ceiling mounting Rear projectionPreparation Connecting the projector to video equipmentViewing video images Basic home theater system connectionViewing video images Connecting to a video player, etcConnecting to a DVD player or Hdtv decoder When a TV tuner or VCR is connectedConnection for video equipment having an Hdmi terminal Connecting to video equipment having a Hdmi terminalPlugging in the power cord Projecting images To stop projecting ZOOM1 ZOOM2 Stretch Setting the aspect ratioWith the remote control How to change the settingsWith the Feature menu See page 26 for menu setting About DDC Connecting the projector to a computerPlugging the power cord Viewing computer imagesComputer Viewing computer imagesExample of the setting procedure for external output When connecting to a notebook computerAuto Position button Contrast B Menu operationImage menu How to set the menusAvailable settings in the menus Menu operationInstallation menu Feature menu User menu Signal menuInformation menu To store the settingsTo enable the stored image quality settings AV memoryTo sharpen or soften the projected image Sharpness Adjusting projected imagesTo adjust the brightness Contrast and Brightness To adjust the color Color and TintTo enable the stored color temperature Adjusting projected imagesTo adjust the tone of white Color Temp About color temperatureNoise reduction To adjust the ratio of change in brightness Gamma ModeLPF To adjust the vertical positionTo cancel the password function Advanced featuresPassword function To enable the password functionReplacing the lamp Interval of lamp replacementTo replace the lamp Reset of the lamp operation timeWhen removing the lamp from the ceiling-mounted projector Replacing the lampCleaning of the lens MaintenanceCleaning of the air-filter Cleaning of the projector and the ventilation slotsFor the air-filter white Accessory air-filter unitAttaching the accessory air-filter unit Cleaning the air-filterNo image appears on the screen Problem Solution TroubleshootingImages are not displayed correctly Problem Solution TroubleshootingOthers Problem Solution Abnormal condition IndicatorsStatus Condition Possible Solution Normal conditionSpecifications Dimension drawings unit mmSpecifications VLT-HC5000LP ConnectorsReplacement part Option/not included in the box Computer IN/COMPONENT Video HdmiMitsubishi Projector Contact Information