InFocus SP-CEIL-UNIV instruction sheet Installation to Concrete Ceilings

Page 4

Installation to Concrete Ceilings

Alligator® concrete anchors are recommended.

Drill two 1/4" (6 mm) dia. holes to a minimum depth of 2.5" (64 mm). Attach ceiling plate (Q) using two concrete anchors (G) and #14 x 2.5" wood screws (F) as shown in Illustration A and 1, 2, and 3. Tighten all fasteners.

Skip to step 7.

G

CONCRETECEILING

WARNING

Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.

Tighten concrete anchor bolt firmly, but do not over- tighten. Overtightening can damage the bolt, greatly reducing its holding power.

Never tighten in excess of 80 in • lb (9 N.M.).

Q

F

Illustration A

WARNING

Concrete anchors are not intended for attachment to concrete wall covered with a layer of plaster, drywall, or other finishing material. If mounting to concrete wall covered with plaster/drywall is unavoidable, plaster/ drywall (up to 5/8" thick) must be counterbored as shown below. If plaster/drywall is thicker than 5/8", custom fasteners must be supplied by installer.

1

Drill hole and insert anchor.

2Q

F

concrete ceiling

G

G

 

 

INCORRECT

 

metal

 

concrete

 

bracket

 

 

VIEW

 

plaster/

 

 

dry wall

 

 

 

 

CUTAWAY

 

CORRECT

 

metal

 

concrete

 

bracket

 

 

 

plaster/

 

 

 

dry wall

 

Place ceiling plate over anchor and secure with screw.

3

F G

After repeating step one tighten all fasteners.

4 of 11

ISSUED: 10-22-04 SHEET #: 055-9236-5 01-10-06

Visit the InFocus Web Site at www.infocus.com

Image 4
Contents Model SP-CEIL-UNIV Installations To Wood Joist Finished CeilingsApplications Parts List AB C D E O PDescription Part NumberInstall two spacers L between ceiling Skip to stepFor optional Cord Management Plate Q and ceilingInstallation to Concrete Ceilings Alligator concrete anchors are recommendedFlush Mount Installation Installation to Extension Column SP-EXTARM-01, SP DetailExtension Column UL Listed Swivel Stop Screw Connection Block Shoulder Adapter Plate Front Projector Issued 10-22-04 Sheet # 055-9236-5 IN72, IN74, IN76 IN24, IN26 Projector Alignment