8
Adjusting the Timing Cycle
The Time Control Dial located on the front panel of the Power Supply can be adjusted to allow more or less time between the cleaner's forward and reverse motion, see Figure 8.
Set your cleaner's Time Control Dial to 30 seconds. The goal is to have your cleaner move across your pool at its widest point, from one side to the other and wait at both sides for approximately 2 seconds before reversing. If this doesn't happen adjust the Time Control Dial accordingly.
NOTE: Turning the Time Control Dial clockwise will lengthen the time between reversals to a maximum time of 90 seconds. Conversely, turning the dial
Once the Time Control is set to your satisfaction, it does not need to be changed unless you use a different type of Filter Bag or there is an excessive amount of debris in your pool.
NOTE: The alternate Mesh Bag may cause the cleaner to cross your pool in less time and the Time
Control should be adjusted accordingly.
Turn Power Supply switch to the “ON” position, see Figure 9 , then press the Reset Button, see Figure 9 .
2 1
Figure 7. | Figure 8. | Figure 9. |
Prowler™ 710 Installation and User’s Guide