Allied Telesis AT-2916LX10/LC-901, AT-2916SX, AT-2931SX, AT-2972T/2, AT-2972SX/2 manual Vlan ID

Page 6

Contents

 

Checksum Offload

66

VLAN ID

67

Wake Up Capabilities

68

WOL Speed

69

Chapter 6: Installing the Linux Driver Software

71

Installing the Linux Driver Software

72

Building a Driver from a TAR File

72

Network Installation

74

Removing the Linux Driver from a TAR Installation

75

Module Parameters

76

Chapter 7: Installing the Novell NetWare Driver Software

83

Driver Installation

84

Pre-Installation Requirements

85

Installing Novell NetWare Server 5.x or 6.0 Driver Software

86

Verifying or Modifying Adapter Parameters

88

Removing Drivers from Autoexec.ncf

93

Chapter 8: Installing the NDIS2 Driver Software for MS-DOS Platforms

95

Installing the NDIS2 Driver Software for Use on MS-DOS Platforms

96

Pre-Installation Requirements

96

Modifying the Startup Disk

96

Using Keywords for the B57.dos Drivers

101

Chapter 9: Installing the PXE Boot Agent

103

Overview

104

Setup BIOS

104

Server Setup

105

Windows Server 2003 and Windows XP

105

DOS UNDI/APITEST

105

Red Hat Linux

105

Chapter 10: Troubleshooting

107

Hardware Diagnostics

108

Checking Port LEDs on the Adapter

109

Troubleshooting Checklist

110

Verifying the Correct Drivers are Loaded

111

NetWare

111

Linux

111

Testing Network Connectivity

112

Windows Server 2003

112

NetWare

114

Linux

114

Software Problems and Solutions

115

Microsoft Remote Installation Service (RIS) Instructions

115

Windows Server 2003

115

Miscellaneous

115

Chapter 11: DOS Diagnostics

117

Introduction

118

DOS Prompt Commands

119

Diagnostic Tests

120

Test Names

120

Test Descriptions

121

Error Messages

127

Appendix A: Specifications

131

Physical Specifications

131

Environmental Specifications

131

Power Specifications

132

Performance Specifications

132

Operating Specifications

133

6

Image 6
Contents Installation Guide Page Electrical Safety and Emissions Standards Translated Safety Statements Contents Vlan ID Page Contents Figures Figures Preface Safety Symbols Used in this Document Symbol Meaning DescriptionWhere to Find Web-based Guides Management Software Updates Contacting Allied TelesisChapter Functional Description Contents of Your Shipment LEDs State DescriptionSoftware Driver Features AT-29xx Series Adapter Software DriversFailover Teaming Installing the Hardware Reviewing Safety Precautions Page Pre-Installation Checklist Installing a Network Adapter Card Removing the PC CoverInstalling the Hardware Make sure the card is securely seated. See Figure Installing the Hardware Connecting the Network Cables Port Type Connector Media Maximum DistanceWarranty Registration Chapter Installing the Driver Software Using the Driver InstallerClick Install from a list or specific location Advanced Click Include this location in the search Updating the Adapter Software Run Window Device Manager Window is shown in Figure Hardware Update Wizard Window Modifying Configuration Properties Click Install from a list or specified location AdvancedPage Uninstalling the Driver Software Page Chapter Selecting the Device Manager Selecting the Device Manager in Windows 2008 R2 and WindowsPage Selecting the Device Manager in Windows Vista Windows Vista Run WindowDevice Manager Window Installing Windows R2, Windows Vista, Driver Software Update Driver Software Ethernet Controller Window Click Browse my computer for driver softwareUpdate Driver Software Confirmation Window Open the Device Manager Page Setting Advanced Properties Opening Advanced Properties Page Setting Advanced Properties Ethernet@Wire- speed AT-2972/T2 only Flow ControlSetting Advanced Properties Interrupt Moderation Setting Advanced Properties Large Send Offload Property Setting Advanced Properties Page Receive Side Scaling Speed & Duplex Mode Checksum Offload Page Wake Up Capabilities Page Setting Advanced Properties Installing the Linux Driver Software Installing the Linux Driver Software Building a Driver from a TAR FileRemoving the tg3 Driver Rmmod tg3 Network Installation Removing the Linux Driver from a TAR Installation Module Parameters ˆ linespeedˆ autospeed ˆ txflowcontrol ˆ fullduplexˆ rxflowcontrol ˆ autoflowcontrolˆ rxchecksum ˆ mtuˆ txchecksum ˆ scattergatherˆ rxjumbodesccnt ˆ adaptivecoalesceˆ rxcoalesceticks ˆ txcoalesceticks ˆ enablewolˆ rxmaxcoalesceframes ˆ txmaxcoalesceframesˆ enabletso Installing the Linux Driver Software Installing the Novell NetWare Driver Software Driver Installation Pre-Installation Requirements NetWare OS Support Pack or Patch Files to be InstalledInstalling Novell NetWare Server 5.x or 6.0 Driver Software Select Save parameters and load driver to continuePage Configuration Parameters for B57.LAN driver Verifying or Modifying Adapter ParametersNODE= FRAME= Poll= Bind IPX B571E82 NET=FAFD3D25 Removing Drivers from Autoexec.ncf ExampleInstalling the Novell NetWare Driver Software Installing the NDIS2 Driver Software for MS-DOS Platforms Pre-Installation Requirements Change DriverName=$ to DriverName=B57$Example Protocol.ini for IP Example Protocol.ini for IPX Example Protocol.ini for NetBEUIChange netcard= to netcard=b57.dos Example SYSTEM.INICopy B57.dos to A\Net For IPXFor NetBEUI SET PATH=A\NET \NET\NET Start BasicUsing Keywords for the B57.dos Drivers Page Installing the PXE Boot Agent Overview Server Setup Windows Server 2003 Windows XPInstalling the PXE Boot Agent 106 Troubleshooting Hardware Diagnostics Checking Port LEDs on the Adapter Troubleshooting Checklist Verifying the Correct Drivers are Loaded Module Size Used byTesting Network Connectivity Type ipconfig /allWindows Server Command Window with ping displayed 114 Software Problems and Solutions Windows XP Image116 DOS Diagnostics Introduction DOS Prompt Commands Command DescriptionGroup B Diagnostic TestsGroup a Group CA3. Interrupt Test A1. Indirect Register TestA2. Control Register Test A5. PCI Cfg Register TestB4. Mbuf Sram Test B2. BD Sram TestB3. DMA Sram Test B5. Mbuf Sram via DMA TestC1. Eeprom Test Default DisabledB6. External Sram Test C2. CPU TestC3. DMA Test C4. MII TestOffset Mask C7. ROM Expansion Test C5. VPD TestC6. ASF Test D1. Mac Loopback TestD3. RJ45 Loopback Test Function Default DisabledD2. Phy Loopback Test D4. MII Miscellaneous TestError Messages Pass128 129 130 Environmental Specifications SpecificationsPhysical Specifications Appendix aPower Specifications Performance SpecificationsOperating Specifications Appendix a Specifications 134 Cleaning Fiber Optic Connectors Appendix BUsing a Cartridge-Type Cleaner Rubbing the Ferrule Tip on the Cleaning Surface137 Using a Swab Cleaning a Recessed Ferrule If desired, repeat step139 Appendix B Cleaning Fiber Optic Connectors 140
Related manuals
Manual 102 pages 40.87 Kb Manual 2 pages 53.07 Kb Manual 82 pages 31.76 Kb

AT-2916LX10/LC-901, AT-2972SX, AT-2972SX/2, AT-2972LX10/LC-901, AT-2916SX specifications

The Allied Telesis AT-2972T/2 is a highly capable 10/100 Mbps Fast Ethernet switch designed to provide reliable performance and advanced management features for small to medium-sized businesses. This switch is built on a robust technology platform, making it an ideal choice for organizations looking to enhance their network infrastructure while ensuring scalability and flexibility.

One of the main features of the AT-2972T/2 is its support for 24 ports, allowing for extensive connectivity in a compact footprint. This makes it suitable for environments where space is limited but connectivity demands are high. With auto-negotiation on all ports, the switch automatically detects the best speed and duplex mode, ensuring optimal performance and seamless integration into existing networks.

The AT-2972T/2 incorporates advanced Layer 2 switching capabilities, enabling efficient handling of data traffic. Its ability to support VLAN (Virtual Local Area Network) tagging allows for network segmentation, improving performance and security. This feature is particularly beneficial for organizations that require different departments or teams to maintain their network traffic separately.

Quality of Service (QoS) is another significant aspect of the AT-2972T/2. The switch provides multiple traffic prioritization levels, ensuring that critical applications receive the necessary bandwidth to function effectively. This is essential in maintaining the performance of real-time applications such as VoIP and video conferencing, which are increasingly crucial in today’s business environment.

The built-in diagnostics features of the AT-2972T/2 enhance its reliability and ease of management. With capabilities such as loop detection and port mirroring, network administrators can quickly troubleshoot issues and monitor traffic flow to ensure a stable network.

Power over Ethernet (PoE) support is available in some configurations of the AT-2972T/2, allowing the switch to deliver power to connected devices such as IP cameras and wireless access points. This capability simplifies installations and reduces the need for additional power sources, streamlining the deployment of network devices.

Furthermore, the switch is designed with energy efficiency in mind, adhering to environmental standards that help organizations reduce their carbon footprint while cutting energy costs.

In summary, the Allied Telesis AT-2972T/2 stands out as a versatile and robust Fast Ethernet switch, equipped with essential features like VLAN support, QoS, PoE, and advanced diagnostics. Its combination of performance, management capabilities, and energy efficiency makes it an excellent choice for businesses aiming to build a reliable and future-proof network infrastructure.