Note

This parameter is ignored and assumed to be 1 if the line_speed parameter is set to 0.

ˆfull_duplex

This parameter is used together with line_speed to select the speed and duplex mode of the link. Note that this parameter is ignored if line_speed is 0. Choose from the following selections:

0 - half duplex

1 - full duplex (default)

ˆrx_flow_control

Enables or disables receiving flow control (pause) frames. This parameter is used together with auto_flow_control. Choose from the following selections:

0 - pause receive disabled

1 - pause receive enabled if auto_flow_control is

set to 0, or pause receive advertised if auto_flow_control is set to 1 (default)

ˆtx_flow_control

Enables or disables transmitting flow control (pause) frames. This parameter is used together with auto_flow_control. Choose from the following selections:

0 - pause transmit disabled

1 - pause transmit enabled if auto_flow_control is

set to 0, or pause transmit advertised if auto_flow_control is set to 1 (default)

ˆauto_flow_control

Enables or disables Auto-Negotiation of flow control. This parameter is used together with rx_flow_control and tx_flow_control to determine the advertised flow control capability. Choose from the following selections:

0 - flow control Auto-Negotiation disabled

1 - flow control Auto-Negotiation enabled with

capability specified in rx_flow_control and

tx_flow_control (only valid if line_speed is set to 0 or auto_speed is set to 1) (default)

77

Image 77
Contents Installation Guide Page Electrical Safety and Emissions Standards Translated Safety Statements Contents Vlan ID Page Contents Figures Figures Preface Symbol Meaning Description Safety Symbols Used in this DocumentWhere to Find Web-based Guides Contacting Allied Telesis Management Software UpdatesChapter Functional Description Contents of Your Shipment State Description LEDsAT-29xx Series Adapter Software Drivers Software Driver FeaturesFailover Teaming Installing the Hardware Reviewing Safety Precautions Page Pre-Installation Checklist Removing the PC Cover Installing a Network Adapter CardInstalling the Hardware Make sure the card is securely seated. See Figure Installing the Hardware Port Type Connector Media Maximum Distance Connecting the Network CablesWarranty Registration Chapter Using the Driver Installer Installing the Driver SoftwareClick Install from a list or specific location Advanced Click Include this location in the search Updating the Adapter Software Run Window Device Manager Window is shown in Figure Hardware Update Wizard Window Click Install from a list or specified location Advanced Modifying Configuration PropertiesPage Uninstalling the Driver Software Page Chapter Selecting the Device Manager in Windows 2008 R2 and Windows Selecting the Device ManagerPage Windows Vista Run Window Selecting the Device Manager in Windows VistaDevice Manager Window Installing Windows R2, Windows Vista, Driver Software Click Browse my computer for driver software Update Driver Software Ethernet Controller WindowUpdate Driver Software Confirmation Window Open the Device Manager Page Setting Advanced Properties Opening Advanced Properties Page Setting Advanced Properties Flow Control Ethernet@Wire- speed AT-2972/T2 onlySetting Advanced Properties Interrupt Moderation Setting Advanced Properties Large Send Offload Property Setting Advanced Properties Page Receive Side Scaling Speed & Duplex Mode Checksum Offload Page Wake Up Capabilities Page Setting Advanced Properties Installing the Linux Driver Software Removing the tg3 Driver Installing the Linux Driver SoftwareBuilding a Driver from a TAR File Rmmod tg3 Network Installation Removing the Linux Driver from a TAR Installation ˆ autospeed Module Parametersˆ linespeed ˆ rxflowcontrol ˆ fullduplexˆ txflowcontrol ˆ autoflowcontrolˆ txchecksum ˆ mtuˆ rxchecksum ˆ scattergatherˆ rxcoalesceticks ˆ rxjumbodesccntˆ adaptivecoalesce ˆ rxmaxcoalesceframes ˆ enablewolˆ txcoalesceticks ˆ txmaxcoalesceframesˆ enabletso Installing the Linux Driver Software Installing the Novell NetWare Driver Software Driver Installation NetWare OS Support Pack or Patch Files to be Installed Pre-Installation RequirementsSelect Save parameters and load driver to continue Installing Novell NetWare Server 5.x or 6.0 Driver SoftwarePage Verifying or Modifying Adapter Parameters Configuration Parameters for B57.LAN driverNODE= FRAME= Poll= Bind IPX B571E82 NET=FAFD3D25 Example Removing Drivers from Autoexec.ncfInstalling the Novell NetWare Driver Software Installing the NDIS2 Driver Software for MS-DOS Platforms Example Protocol.ini for IP Pre-Installation RequirementsChange DriverName=$ to DriverName=B57$ Example Protocol.ini for NetBEUI Example Protocol.ini for IPXExample SYSTEM.INI Change netcard= to netcard=b57.dosFor IPX Copy B57.dos to A\NetSET PATH=A\NET \NET\NET Start Basic For NetBEUIUsing Keywords for the B57.dos Drivers Page Installing the PXE Boot Agent Overview Windows Server 2003 Windows XP Server SetupInstalling the PXE Boot Agent 106 Troubleshooting Hardware Diagnostics Checking Port LEDs on the Adapter Troubleshooting Checklist Module Size Used by Verifying the Correct Drivers are LoadedWindows Server Testing Network ConnectivityType ipconfig /all Command Window with ping displayed 114 Windows XP Image Software Problems and Solutions116 DOS Diagnostics Introduction Command Description DOS Prompt CommandsGroup a Diagnostic TestsGroup B Group CA2. Control Register Test A1. Indirect Register TestA3. Interrupt Test A5. PCI Cfg Register TestB3. DMA Sram Test B2. BD Sram TestB4. Mbuf Sram Test B5. Mbuf Sram via DMA TestB6. External Sram Test Default DisabledC1. Eeprom Test C2. CPU TestOffset Mask C3. DMA TestC4. MII Test C6. ASF Test C5. VPD TestC7. ROM Expansion Test D1. Mac Loopback TestD2. Phy Loopback Test Function Default DisabledD3. RJ45 Loopback Test D4. MII Miscellaneous TestPass Error Messages128 129 130 Physical Specifications SpecificationsEnvironmental Specifications Appendix aPerformance Specifications Power SpecificationsOperating Specifications Appendix a Specifications 134 Appendix B Cleaning Fiber Optic ConnectorsRubbing the Ferrule Tip on the Cleaning Surface Using a Cartridge-Type Cleaner137 Cleaning a Recessed Ferrule If desired, repeat step Using a Swab139 Appendix B Cleaning Fiber Optic Connectors 140
Related manuals
Manual 102 pages 40.87 Kb Manual 2 pages 53.07 Kb Manual 82 pages 31.76 Kb

AT-2916LX10/LC-901, AT-2972SX, AT-2972SX/2, AT-2972LX10/LC-901, AT-2916SX specifications

The Allied Telesis AT-2972T/2 is a highly capable 10/100 Mbps Fast Ethernet switch designed to provide reliable performance and advanced management features for small to medium-sized businesses. This switch is built on a robust technology platform, making it an ideal choice for organizations looking to enhance their network infrastructure while ensuring scalability and flexibility.

One of the main features of the AT-2972T/2 is its support for 24 ports, allowing for extensive connectivity in a compact footprint. This makes it suitable for environments where space is limited but connectivity demands are high. With auto-negotiation on all ports, the switch automatically detects the best speed and duplex mode, ensuring optimal performance and seamless integration into existing networks.

The AT-2972T/2 incorporates advanced Layer 2 switching capabilities, enabling efficient handling of data traffic. Its ability to support VLAN (Virtual Local Area Network) tagging allows for network segmentation, improving performance and security. This feature is particularly beneficial for organizations that require different departments or teams to maintain their network traffic separately.

Quality of Service (QoS) is another significant aspect of the AT-2972T/2. The switch provides multiple traffic prioritization levels, ensuring that critical applications receive the necessary bandwidth to function effectively. This is essential in maintaining the performance of real-time applications such as VoIP and video conferencing, which are increasingly crucial in today’s business environment.

The built-in diagnostics features of the AT-2972T/2 enhance its reliability and ease of management. With capabilities such as loop detection and port mirroring, network administrators can quickly troubleshoot issues and monitor traffic flow to ensure a stable network.

Power over Ethernet (PoE) support is available in some configurations of the AT-2972T/2, allowing the switch to deliver power to connected devices such as IP cameras and wireless access points. This capability simplifies installations and reduces the need for additional power sources, streamlining the deployment of network devices.

Furthermore, the switch is designed with energy efficiency in mind, adhering to environmental standards that help organizations reduce their carbon footprint while cutting energy costs.

In summary, the Allied Telesis AT-2972T/2 stands out as a versatile and robust Fast Ethernet switch, equipped with essential features like VLAN support, QoS, PoE, and advanced diagnostics. Its combination of performance, management capabilities, and energy efficiency makes it an excellent choice for businesses aiming to build a reliable and future-proof network infrastructure.