10 | Port Interface Card |
6.Load the protocol image onto the PIC.
To load the protocol image, use the command:
enable voip protocol={h323sip} [engine={engine}]
The boot code loads the protocol onto all
Once the firmware is loaded, all the LEDs turn off. The following figure shows an example of the firmware download process. User input is shown in bold.
Manager> set voip
Manager> set voip fi=hs-1-0-0.bin protocol=h323
Info (1110003): Operation successful.
Manager> set voip public int=eth0
Info (1110003): Operation successful.
Manager> ena voip protocol=h323
Info (1110282): VoIP PIC BAY0:Firmware is loading...
Info (1110282): VoIP PIC BAY1:Firmware is loading...
Manager>
Info (1110293): VoIP PIC BAY0:Firmware successfully loaded. Manager>
Info (1110293): VoIP PIC BAY0:Firmware is now running. Manager>
Info (1110293): VoIP PIC BAY1:Firmware successfully loaded. Manager>
Info (1110293): VoIP PIC BAY1:Firmware is now running.
7.Save the configuration.
Save your configuration to a new file by using the command: create config=filename.cfg
Then set the router to load this file when it restarts by using the command: set config=filename.cfg
We recommend leaving the boot.cfg file unchanged, in case you need to revert to the original default configuration.