6b the Antenna Interfaces4103 and 4203

1.Connect the Antenna interface (N-Type connector) of the MAIN TRACER 4103/4203 (labeled 1 below) to the MAIN RF interface (SMA connector) of the TRACER MPS (labeled 2 below) using a male N-Type to male SMA cable.

2.Repeat Step 1 to connect the Antenna interface (N-Type connector) of the STANDBY TRACER 4103/4203 to the STANDBY RF inter- face (SMA connector) of the TRACER MPS (labeled 3 below).

1 MAIN UNIT Antenna Interface

T1B

T1A

TRACER MPS MAIN

2

Antenna Interface

 

T

MAIN

ALARMS

DC POWER

 

 

 

 

 

R

 

OUT

IN

POWER

 

MODULE

A

 

 

 

 

C

 

 

 

 

E

 

 

 

 

R

STANDBY

 

 

USE COPPER

TO DTE RS-232

 

NO COM NC

MN COM SB

 

CONDUCTORS ONLY

TRACER MPS STANDBY 3

Antenna Interface

 

RF

 

 

 

 

 

 

 

 

 

T1B

 

 

 

 

T1A

 

 

 

MAIN

 

 

 

 

 

 

MAIN

 

STANDBY

 

 

 

 

 

 

 

 

 

MONITOR

 

 

 

 

MONITOR

TRACER

 

TRACER

STAND

 

 

 

 

 

 

 

BY

 

 

 

 

 

 

 

 

 

 

ANTENNA

OUT

IN

IN

OUT

B

A

B

A

4 MAIN UNIT Antenna Interface

3.Connect the TRACER MPS Antenna interface (N-Type connector, labeled 4 above) to the customer provided antenna using antenna feedline cabling. Refer to the appropriate TRACER User Manual for a detailed discussion on link planning, antenna loss/gain, and antenna alignment.

7

Image 7
Contents Tracer Monitored Protection Switch MPS Main Tracer RFC Main Tracer BBP Standby Unit VT100 Connection Main Unit VT100 ConnectionReviewing the Menus Main T1A Interface Main Unit T1B Interface Main Unit T1A InterfaceInterfaces Tracer MPSTracer MPS Main Tracer RFC if Interface Main Unit Antenna InterfaceTracer BBP if Interface Tracer MPS Antenna InterfaceTracer MPS Standby Connect to External Alarm COM Alarm Contact System No Alarm Contact COM Alarm ContactMN Alarm Contact SB Alarm Contact Pin Name Description

Protection Switch specifications

ADTRAN Protection Switch is an innovative solution designed to enhance network reliability and resilience through effective protection and failover mechanisms. This cutting-edge technology is primarily utilized in telecommunications and data networks, ensuring continuous service availability even in the face of failures or disruptions.

One of the standout features of the ADTRAN Protection Switch is its ability to provide seamless protection switching between primary and backup paths. Leveraging advanced algorithms, the system can detect any failures in the primary data path and automatically reroute traffic to a predefined backup path within milliseconds. This instantaneous failover capability minimizes downtime and ensures that critical data traffic continues to flow without interruption.

The ADTRAN Protection Switch employs various technologies to achieve high levels of performance and reliability. Among these, the use of Ethernet, MPLS (Multiprotocol Label Switching), and fiber optics allows for high-speed data transmission and improved bandwidth utilization. The integration of these technologies ensures that organizations can maintain performance standards in demanding environments.

Another essential characteristic of the ADTRAN Protection Switch is its scalability. The modular design allows for easy expansion and integration with existing network infrastructures. As organizations grow and their network needs change, the protection switch can be adjusted to accommodate increased traffic loads or additional service requirements without requiring a complete overhaul of the system.

Moreover, the ADTRAN Protection Switch supports advanced management features, including network monitoring and diagnostics. Users can access real-time performance analytics and alerts, empowering network administrators to proactively address potential issues before they affect service quality. This comprehensive management capability ensures consistent network performance and facilitates prompt troubleshooting.

In addition to its robust technical features, the ADTRAN Protection Switch is designed with redundancy in mind. Dual power supplies and redundant components ensure that the device remains operational even if one part fails. This level of reliability is crucial for organizations that cannot afford outages, especially those in critical sectors like healthcare, finance, or emergency services.

Ultimately, the ADTRAN Protection Switch represents a significant advancement in network protection technology. With its state-of-the-art features, adaptability, and commitment to reliability, it provides organizations with the confidence that their data services will remain uninterrupted, even in the face of unexpected events. This makes it an invaluable asset in today's increasingly interconnected digital landscape.