ADTRAN Protection Switch quick start Reviewing the Menus

Page 4

4 Reviewing the Menus

The TRACER MPS software interface consists of a single menu screen (shown below). Navigate through the available menu options using the up and down arrow keys. Alternately, the numbered menu options may be selected by entering the appropriate menu number displayed to the left of the option. Pressing the <space bar> activates the current menu selection. The TRACER MPS VT100 interface provides access to the MAIN and STANDBY TRACER unit menus (using menu options 1 and 2, respectively). Press <Ctrl + R> to exit the TRACER menus and return to the TRACER MPS menu screen. A brief description of the available menu options for the TRACER MPS follows the figure below.

Status of MAIN

1

2

Status of STANDBY

TRACER system

TRACER system

 

4

 

 

 

5

7

 

6

 

8

 

 

9

10

Navigational Help

4 Activates the menu system for the MAIN TRACER unit. This provides access to all configuration and status parameters.

5 Activates the menu system for the STANDBY TRACER unit. This provides access to all configuration and status parameters.

6Configures the TRACER MPS for modem or terminal access. When connecting a VT100 terminal or PC with terminal software, select DISABLED.To connect a modem to the TRACER MPS RS-232 interface, set this parameter to ENABLED. To disable the modem

control, press <Ctrl + Z> three times.

7Specifies the frequency band of the MAIN and STANDBY TRACER units as 5.8 GHz or 2.4 GHz. This menu setting should match the operational frequency of your TRACER systems, and must be manually configured by the user prior to operation.

8 Number of seconds the TRACER MPS waits (after a switch to the STANDY system) before attempting to restore MAIN operation.

9Number of contiguous seconds the MAIN TRACER system must exhibit an alarm condition before the TRACER MPS switches to STANDBY operation.

10Provides instructions for navigating through the menus using the arrow keys or entering the menu number and activating the highlighted menu by pressing the space bar.

4

Image 4
Contents Tracer Monitored Protection Switch MPS Main Tracer RFC Main Tracer BBP Main Unit VT100 Connection Standby Unit VT100 ConnectionReviewing the Menus Main Unit T1B Interface Main Unit T1A Interface InterfacesTracer MPS Main T1A InterfaceTracer RFC if Interface Main Unit Antenna Interface Tracer BBP if InterfaceTracer MPS Antenna Interface Tracer MPS MainTracer MPS Standby Connect to External Alarm COM Alarm Contact System No Alarm Contact COM Alarm ContactMN Alarm Contact SB Alarm Contact Pin Name Description

Protection Switch specifications

ADTRAN Protection Switch is an innovative solution designed to enhance network reliability and resilience through effective protection and failover mechanisms. This cutting-edge technology is primarily utilized in telecommunications and data networks, ensuring continuous service availability even in the face of failures or disruptions.

One of the standout features of the ADTRAN Protection Switch is its ability to provide seamless protection switching between primary and backup paths. Leveraging advanced algorithms, the system can detect any failures in the primary data path and automatically reroute traffic to a predefined backup path within milliseconds. This instantaneous failover capability minimizes downtime and ensures that critical data traffic continues to flow without interruption.

The ADTRAN Protection Switch employs various technologies to achieve high levels of performance and reliability. Among these, the use of Ethernet, MPLS (Multiprotocol Label Switching), and fiber optics allows for high-speed data transmission and improved bandwidth utilization. The integration of these technologies ensures that organizations can maintain performance standards in demanding environments.

Another essential characteristic of the ADTRAN Protection Switch is its scalability. The modular design allows for easy expansion and integration with existing network infrastructures. As organizations grow and their network needs change, the protection switch can be adjusted to accommodate increased traffic loads or additional service requirements without requiring a complete overhaul of the system.

Moreover, the ADTRAN Protection Switch supports advanced management features, including network monitoring and diagnostics. Users can access real-time performance analytics and alerts, empowering network administrators to proactively address potential issues before they affect service quality. This comprehensive management capability ensures consistent network performance and facilitates prompt troubleshooting.

In addition to its robust technical features, the ADTRAN Protection Switch is designed with redundancy in mind. Dual power supplies and redundant components ensure that the device remains operational even if one part fails. This level of reliability is crucial for organizations that cannot afford outages, especially those in critical sectors like healthcare, finance, or emergency services.

Ultimately, the ADTRAN Protection Switch represents a significant advancement in network protection technology. With its state-of-the-art features, adaptability, and commitment to reliability, it provides organizations with the confidence that their data services will remain uninterrupted, even in the face of unexpected events. This makes it an invaluable asset in today's increasingly interconnected digital landscape.