Table
Table 2-6. Connector and Splice Insertion Loss
Connector Type | Range of Loss Per Pair (dB) | Typical Loss | |
(dB) | |||
|
| ||
|
|
| |
SMA Patch Panel | 1.0 to 3.0 | 2.0 | |
|
|
| |
ST or FC Patch Panel | 0.1 to 0.75 | 0.5 | |
|
|
| |
Splice Type | Range of Loss (dB) | Typical Loss | |
(dB) | |||
|
| ||
|
|
| |
Fusion | 0.01 to 0.1 | 0.05 | |
|
|
| |
Mechanical | 0.2 to 1.0 | 0.5 | |
|
|
|
Optical Fiber Loss
Even though fiber optic cable can carry light signals over a long distance, optical power loss is a significant factor. Check your cable manufacturer's rating of the loss characteristic of your fiber cable to determine the actual loss.
Table
Table 2-7. Typical Fiber Loss Characteristics
Fiber Type | Loss (dB/km) | Typical Loss | |
(dB/km) | |||
|
| ||
|
|
| |
50/125 micron @ 820 nM | 3 to 5 | 3.75 | |
|
|
| |
62.5/125 micron @ 820 nM | 3 to 5 | 3.75 | |
|
|
| |
85/125 micron @ 820 nM | 3 to 6 | 4.0 | |
|
|
| |
100/140 micron @ 820 nM | 3 to 6 | 5.0 | |
|
|
|
Designing and Expanding the Network 2 - 11