3Com 5104M-FB1, 5102M-FBP, 510M-FBP installation and operation guide Precautionary Procedures

Page 58

Note: Read the precautionary procedures before unpacking the module.

Precautionary Procedures

Electrostatic discharge (ESD) can damage static-sensitive devices on circuit boards. Follow these precautions when you handle the 10BASE-FB Modules:

Do not remove the board from its anti-static shielding bag until you are ready to inspect it.

Handle the board by the faceplate.

Use proper grounding techniques when you install a 10BASE-FB Module. These techniques include:

Using a foot strap and grounded mat or wearing a grounded static discharge wrist strap.

Touching the grounded rack or other source of ground just before you handle a 10BASE-FB Module.

3 - 2 ONline Ethernet 10BASE-FB Module Installation and Operation Guide

Image 58
Contents Page VDE Class B Compliance Restricted Rights Page Contents Installing and Operating the Module Appendix a Specifications Page Figures Page Tables Page How to Use This Guide AudienceStructure of This Guide Convention Indicates Example Document ConventionsUsr/snm/agents Related Documents 3Com DocumentsSlot ONline System Concentrator Installation and Operation Reference DocumentsPage Introduction 10BASE-FB Module Descriptions Introduction 1 10BASE-FB Compliance Theory of OperationBASE-FB Module Connections BASE-FB Module Compatibility Compatibility With Other Ethernet Fiber Products3Com Product Part Number Designing and Expanding the Network Basic Network Rules Rules for Configuring a NetworkUnderstanding the General Rules Rule Definition Recommendations/NotesDefinition Recommendations/Notes Is actually equal to 1.1 meters Equivalent Fiber Distances of LAN Products Equivalent Fiber DistancesLAN Product Equivalent Fiber Determining Maximum Fiber Link Distances Calculating Maximum Link Distance Determining Link BudgetLink Link Loss ONline 10BASE-FB Module Optical Power Budget Normal PowerPower DBmCable Size Used Transmit Receive Optical Power Micron ONline 10BASE-FB Module Optical Power Budget High PowerBASE-FB Optical Power Budget ONline toAttenuation Connector and Splice Insertion Loss Typical Fiber Loss CharacteristicsExample 1700 Meter Fiber Link With Mechanical Splice Meter Fiber Link With Mechanical SpliceExample 2000 Meter Fiber Link Through Two Patch Panels Meter Fiber Link Through Two Patch PanelsChoosing a Network Backbone Cabling Structure Star Configuration Star-Wiring ConfigurationSerial Configuration Serial Configuration Using 10BASE-FB Modules10BASE-FB Module Configurations Fiber Backbone, Fiber-to-the-DeskAll-Fiber Network Example Network With 3 Concentrators Network With 3 ConcentratorsNetwork Configured With 8 Concentrators Example Network with 8 ConcentratorsFiber Equivalent Distances Between Transceivers Example Sample Configuration Distance Calculation Fiber Backbone, Unshielded Twisted Pair to-the-DeskSample Configuration Distance Calculation Example Connecting a Thin Ethernet 10BASE2 Segment Fiber Backbone, Coaxial ConnectionDesigning and Expanding the Network 2 Configuring Ports for Fault Tolerance Fault-Tolerant ConfigurationsStandard Redundant Configuration In this configuration Setting Redundancy 10. Redundant Fiber Backbone Configuration Implementing Total Backbone Fault Tolerance 11. Total Backbone Fault-Tolerant Configuration 12. Fiber Network With 3 Concentrators Page Installing and Operating the Module Precautionary Procedures Unpacking Procedures Quick Installation Procedures Quick InstallationStep Procedure Section Title Setting the Dip Switches BASE-FB Module Dip Switch Locations Dip Switch S1 Settings for Switches 1 Setting Dip Switch S1Switch Label Function Factory Switch Setting Default Off Module-Switching Module Dip Switch S1 Settings for Switches 3 toPort-Switching Module Port Channel SelectionDip Switch S2 Settings Setting Dip Switch S2Switch Label Function Factory Switch Setting Default Installing the Module Enable/disable Disable Module Low Light Detection Not UsedInstalling the 10BASE-FB Module BASE-FB Module Connection Configuring the Module Enabling Ports Selecting a Network You can enable port redundancy in one of the following ways Enabling Port RedundancyEnabling Optical Power Enabling Low Light WarningShowing Module Configuration Saving Module ConfigurationMonitoring the Front Panel Page Interpreting the 10BASE-FB Module LEDs LED Name Color State IndicatesVerifying LED and Network Assignments LED State Network ConfigurationNetwork Check Codes Troubleshooting Troubleshooting Using the Port Activity LEDs Troubleshooting Using the Port Activity LEDsPossible Cause Corrective Action Troubleshooting Using the Port Status LEDs Troubleshooting Using the Port Status LEDsLED State Indication Possible Cause Corrective Action Troubleshooting Using the Port Status LEDs Troubleshooting Using the Port Status LEDs 10BASE-FL Technical Assistance Page Specifications General Specifications Table A-1. General SpecificationsTable A-2. Transmit Power Optical SpecificationsTransmitter Specifications Cable Type Normal Power High PowerTable A-3. Receiver Specifications Receiver SpecificationsSupported Fiber Optic Cables Table A-5. Power Requirements Power RequirementsTable A-4. Fiber Optic Interface Specifications Fiber Optic InterfaceTable A-6. Electrical Specifications Environmental SpecificationsMechanical Specifications Table A-7. Mechanical Specifications10BASE-FB Cable and Connector Specifications 10BASE-FB CablesPort-Switching Connector Type 10BASE-FB ConnectorsTable A-8 BASE-FB Module Part Numbers Technical Support On-line Technical SupportEmail Technical Support Support from Your Network SupplierWorld Wide Web Site Support from 3Com Accessing the 3Com MIB Returning Products for Repair3Com Technical Publications Page Index Installing Link Budget Redundant Link, 3-16Redundancy LED Unpacking Procedures, 3-3Unshielded Twisted Pair Cable