Desa CSG3930PR To Turn Off Gas To Appliance, Thermostat Control Operation, Shutting Off Heater

Models: CSG3930NR CSG3930PR

1 38
Download 38 pages 12.29 Kb
Page 18
Image 18
TO TURN OFF GAS

18

OPERATING HEATER (THERMOSTAT-CONTROLLED MODELS)

Lighting Instructions (Cont.)

To Turn Off Gas To Appliance

Thermostat Control

Manual Lighting Procedure

OPERATING HEATER

Continued

Note: Home owners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the HI heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat.

Shutting Off Heater WARNING: Damper handle will be hot if heater has been running.

1.STOP! Read the safety information on page 17, column 2.

2.Make sure equipment shutoff valve is fully open.

3. Turn control knob clockwise ClockwiseShutting Off Burners Only (pilot stays lit) to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information, page 17, column 2. If you don’t smell gas, go to the next step.

5.Turn control knob counterclockwise THERMOSTAT CONTROL to the PILOT position. Press in control knob for five (5) seconds (see Figure 28).

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system.

6.With thermostat control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute for sys- tem to reset before lighting pilot again.

8.Turn control knob counterclockwise MANUAL LIGHTING to desired heating level. The front burner should light. Set control knob to any heat level between HI and LO.

9.To light the rear yellow flame burner, push in and turn

rear burner control knob counterclockwise Manual background to the ON position.

Manual background CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

Ignitor Button

Control Knob

 

Rear Burner

 

Control Knob

Models: CSG3924NT, CSG3924PT,

VRL24NT, VRL24PT, VRL30NT and VRL30PT

Figure 28 - Control Knob(s) and Ignitor Button Locations

Pilot Burner

Ignitor

Ignitor Electrode

Thermocouple

 

Electrode

Thermocouple

Pilot Burner

 

Figure 29 - Pilot (Propane/LP) Figure 30 - Pilot (Natural)

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise Manual background to the OFF position.

2.Turn rear burner control knob clockwise Manual background to the OFF position.

Shutting Off Burners Only (pilot stays lit)

1.Turn control knob clockwise Manual background to the PILOT position.

2.Turn rear burner control knob clockwise Manual background to the OFF position.

THERMOSTAT CONTROL

OPERATION

The thermostat control knob can be set to any comfort level between HI and LO. The thermostat will gradually modulate the heat output and flame height from higher to lower settings, or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

Note: Selecting the HI setting with the control knob will cause the burner to remain fully on, without modulating down in most cases.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Lighting Instructions, page 18.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 8 and 9 under Lighting Instructions, column 1.

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

110021-01G

Page 18
Image 18