Setting the Dip Switches
The 10BASE-FB Modules have two 10-position dip switches (S1 and S2) located on the board. Figure 3-1 shows the dip switches on the 10BASE-FB Modules and the factory settings.
❑Dip switch S1 on the Port-Switching Module differs from dip switch S1 on the Module-Switching Module. Figure 3-1 contains examples of both dip switches.
❑Dip switch S2 is identical for both the Port-Switching Module and Module-Switching Module except the Module-Switching Module does not provide High power optics.
You may need to reconfigure one or more of these switches depending on your configuration requirements.
The dip switch settings for the 10BASE-FB Modules are ignored if an ONline management module is installed in the concentrator. For this reason, use the management commands (rather than the dip switches) to configure the 10BASE-FB Modules. If you have an installed management module, install the 10BASE-FB Module first and then refer to the Configuring the Module section in this chapter for more information.
This section describes:
❑Setting Dip Switch S1
❑Setting Dip Switch S2