Appendix C: Using the AFU for DOS ● 65
Example
The following example shows a typical system response after a VERIFY command has been performed:
A:\> AFU VERIFY /C 0
Adaptec Flash Utility V1.0-0 B1406
(c)Adaptec Inc.
File: Checksum: 642C [VALID] (Build 1406)
File: Checksum: 642C [VALID] (Build 1406) Verified Successfully
VERSION
The VERSION command displays version information about the flash components on a HostRAID controller.
Command Syntax
The command syntax for the VERSION command is as follows:
AFU VERSION [/C<Controller ID>]
Command Switches
For details on the /C switch, see SAVE on page 63.
Example
The following example displays version information about all supported HostRAID controllers:
A:\> AFU VERSION /C 0
Adaptec Flash Utility
(c)Adaptec Inc.
Version Information for Controller #0 (Adaptec
ROM: Build 1406 [VALID]
AFU Command Line – Step-by-Step
This section provides
To update the flash using the AFU command line:
1Shut down the computer.
2Insert the bootable disk that contains the AFU utility.
3Turn on the computer.
4Enter the system setup utility and verify that your computer is set up to boot from the bootable disk.