OPERATION

Sound Hazard - Sound level from siren speaker (>120dBA @ 10 feet) may cause hearing damage. Do not operate siren without adequate hearing protection for you and anyone in immediate vicinity. (Ref. OSHA 1910.95 for occupational noise exposure guidelines)

RADIO

 

SIREN

 

 

HORN

 

PA

 

 

VOL

MAN

 

 

WAIL

OFF

ON

 

 

YELP

 

 

PHASER

 

 

SA400

The OFF/ON Rocker Power Switch controls the siren power. The siren may be left on any time the vehicle is in operation. The power should be turned off when vehicle is not being used to conserve battery power.

The Rotary Function Switch selects various operating modes. These modes are as follows:

RADIO -

This mode reproduces, or repeats, the output of a radio. The radio must be connected and

 

RADIO VOLUME ADJUSTed for this mode to function. No overrides available in this mode.

HORN -

Also considered a standby mode. Horn and PA Override available in this mode.

MAN -

The siren tone is controlled Manually with SIREN button. PA Override available in this mode.

WAIL -

The siren produces a normal rise-fall tone pattern. This mode should be used on highways or

 

areas with constant traffic flow. Yelp and PA Override available in this mode.

YELP -

The siren produces a moderate warble tone. This mode should be used in lightly congested

 

areas. Horn and PA Override available in this mode.

PHASER -

The siren produces a very fast warble tone. This mode should be used at intersections or in

 

highly congested areas. Horn and PA Override available in this mode.

OVERRIDE FUNCTIONS

PUBLIC ADDRESS

(PA) OVERRIDE - By pressing the microphone button any siren tone output is turned off, allowing the operator to use the siren as a public address amplifier. The siren tone resumes when the button is released. (Hold the microphone close to your lips for proper operation and adjust the PA VOLume Control)

HORN OVERRIDE - By pressing the SIREN button the siren tone output is replaced by the horn tone. The siren tone resumes when the button is released. (This feature is not available in WAIL mode.)

YELP OVERRIDE - Available only in WAIL mode. By momentarily pressing the SIREN button the tone output is switched to the Yelp tone. Pressing the button again switches the tone output back to Wail.

RADIO VOLUME ADJUST

The RADIO VOLUME ADJUST is a one time setting which depends on the radio connected and its normal volume.

The siren cover must be removed to access the adjustment. The cover is held in place by a snap-fastener on the back of the unit. While holding the case on the sides press hard with your thumbs on the back of the unit. The chassis will slide out the front.

Switch siren to RADIO mode and turn on the power. With the volume on the radio itself set to normal level, set the RADIO VOLUME ADJUST to the desired level. Turn off power and press the chassis back into the cover.

RADIO VOLUME ADJUST

TB0325B

Page 5 of 7

10/18/03

Image 5
Contents Technical Bulletin Input Power SA-400-93 SpecificationsSiren Mode Output Power Audio Mode Output PowerMounting InstallationSafety Precautions Electrical Connections Wiring Harness ConnectionsOperation Problems ServiceSymptom Possible Cause Check ReturnDescription Parts

SA-400-93 28V, SA-400-93 PG, SA-400-93 14V specifications

The Carson SA-400-93 series comprises advanced power supply units specifically designed for demanding applications in various fields, including telecommunications, aerospace, and military. This series includes three key models: the SA-400-93 14V, SA-400-93 28V, and SA-400-93 PG, each engineered to deliver reliable and efficient performance while meeting stringent industry standards.

One of the standout features of the SA-400-93 series is its versatility. The 14V and 28V models can adapt to a variety of input voltage requirements, making them ideal for use in both civilian and military equipment. This flexibility ensures they can be seamlessly integrated into existing systems without the need for extensive modifications. The PG version further expands this adaptability by incorporating enhanced features tailored for rugged environments, providing additional options for users who require more specialized performance.

All models in the SA-400-93 series boast impressive efficiency ratings, reaching upwards of 90%. This high efficiency translates to less energy loss in the form of heat, which contributes to a more sustainable power supply solution. Additionally, lower heat generation prolongs the lifespan of the units and enhances reliability, making these power supplies suitable for long-term deployment in critical applications.

In terms of technology, the SA-400-93 series incorporates advanced switching power supply technology. This method allows for compact design while maintaining high output power and stability under varying loads. With built-in protection features, such as over-voltage protection, over-current protection, and thermal shutdown, these units ensure safe operation under demanding conditions.

Another notable characteristic is the rugged construction of the SA-400-93 PG version, which is specifically engineered to withstand extreme environmental conditions, including temperature fluctuations, humidity, and shock. This makes the PG variant an excellent choice for military and field applications, where reliability and durability are paramount.

Overall, the Carson SA-400-93 14V, SA-400-93 28V, and SA-400-93 PG power supply units represent a cutting-edge solution for users in need of robust, efficient, and reliable power sources. With their innovative technologies, comprehensive protective features, and adaptability to varied input voltage requirements, these models stand out as exemplary choices in the landscape of modern power supply solutions. The SA-400-93 series continues to meet the evolving demands of industries that rely on high-quality power systems for their critical operations.