cable length (in feet) 5feet
10feet
40feet
80feet
| standard | power loss into | power loss into | power lossinto |
wire gauge | ||||
(AWG) | 8 Ω load (%) | 4 Ω load (%) | 2 Ω load (%) | |
| 18 | .79 | 1.58 | 3.16 |
| 16 | .50 | 1.00 | 2.00 |
| 14 | .31 | .62 | 1.24 |
| 12 | .20 | .40 | .80 |
| 10 | .125 | .25 | .50 |
|
|
|
|
|
18 | 1.58 | 3.16 | 6.32 | |
16 | 1.00 | 2.0 | 4.00 | |
14 | .62 | 1.25 | 2.50 | |
12 | .40 | .80 | 1.60 | |
10 | .25 | .50 | 1.00 | |
|
|
|
| |
| 18 | 8.00 | 12.60 | 25.20 |
| 16 | 4.00 | 8.00 | 1.60 |
| 14 | 2.50 | 5.00 | 10.00 |
| 12 | 1.60 | 3.20 | 6.40 |
| 10 | 1.00 | 2.00 | 4.00 |
| 8 | .625 | 1.25 | 2.50 |
|
|
|
|
|
16 | 8.00 | 16.00 | 32.00 | |
14 | 5.00 | 10.00 | 20.00 | |
12 | 3.20 | 6.40 | 12.80 | |
10 | 2.00 | 4.00 | 8.00 |