Standard Installation Questions for the MDS-6

Can I control volume and source selection with a wireless remote?

Yes, the MCS-1 and the MCS-2 controllers have a built-in IR emitter that will teach learning remote the ChannelPlus IR codes for volume, source selection, and mute.

How do I control IR if I am using more than one MDS-6 amplifier?

The best solution is to use “Y” cords with two 1/8” male ends going to a 1/8” female end. This works with the 4 source outputs as well as the 4 summed outputs.

Can I use more than one controller within a single zone?

Yes, the controllers can be tied together via a cat. 5 “Y” cord or an RJ45-Y adapter. We suggest using only two controllers within one zone. It is also possible to control two zones with one controller.

Can I use more than one pair of speakers within a single zone?

The MDS-6 is intended to be used with two 8 ohm speakers per zone. It is equipped with line level preamp outs for each zone. You can line out to any external amplifier using standard RCA cables. This makes it possible to power additional speakers, or a powered subwoofer for surround sound systems.

Do I have to have all zones playing music to be able to hear the doorbell and page?

No, the page and doorbell features will work regardless of the status of the zones. You can, however, use internal switches on each zone to defeat the doorbell and page, or allow the doorbell and page without muting the system.

Can I program functions into a macro other than my audio equipment?

The MCS-2 controller will learn and store any IR code in its memory. Once an IR command is programmed, that can then be used as part of a series of macro commands. It is important to note that the MCS-2 can only do macros on commands that have already been stored into the controller's memory.

Do I need to have a backup for the memory in case of a power outage?

No, the MCS-2 controller has a non-volatile memory that will retain its memory once the controller has been programmed.

How do I utilize the doorbell and page features?

The doorbell and page can be wired with simple two-conductor doorbell wire or standard twisted pair wire such as Cat. 5 or Cat. 3. The doorbell can be lined off of the existing doorbell transformer, or from the doorbell strike on the phone system. Since this feature utilizes a voltage to trigger an internal closure, a 9-volt battery will trigger the doorbell chimes. The page function can be used in two different ways. The simplest method is to take the audio line out from your phone system directly to the audio in on the MDS-6. The MDS-6 is designed to sense the incoming signal and mute the system until a signal is no longer present, at which point it will return to normal operation. It may be necessary to adjust the sensitivity on the page/doorbell board of the MDS-6 to compensate for additional noise in the phone line. An alternative solution to eliminate sensitivity problems between the MDS-6 and the phone system is to add a second power supply (this can be a typical "wall wart") to one of the contact relays on the phone system and from there to the mute input on the MDS-6. This will mute the system regardless of an incoming audio signal, and will remain muted until the phone is hung up.

What if none of the lights on the controller come on?

It could be that the “POWER” button is not depressed on the MDS-6. Next verify that you have a source plugged in and playing. Remember that the MDS-6 will go into standby mode after approximately 2 minutes if no incoming signal is detected. If both of these conditions have been met then you probably have an incorrectly wired Cat-5 cable. The correct pin assignment from end to end is: 1 to 8, 2 to 7, 3 to 6, 4 to 5, 5 to 4, 6 to 3, 7 to 2, and 8 to 1.

Page 11

Image 19
Contents Six-Source Six-Zone Music Distribution Amplifier Tel -999-5225 Fax Page Defg H Distribution Section Output SectionPAGING/VOLTAGE Control Section Controller SectionWiring Diagram for Remote Room Controllers MDS-6 Installation Manual MDS-6 Installation Manual Telephone Entry Systems DOORBELL/PAGING PC Board Fig. #2 MDS MCS-1 Controller MCS-2 Controller MCS-2 Controller cont’d Programming Individual Functions Programming the MCS-2 ControllersMacro Programming Page Standard Installation Questions for the MDS-6 Page Installation Notes Warranty Specifications