MCS-2 CONTROLLER
The left side of this controller is identical to the
8.) Reset
9.) Clear
10.) Clone RX
11.) Clone TX
12.) Clone/Learn LED
13.) OK LED
14.) Learn Button
15.) IR Sensor LED
|
|
|
| ||
|
| RESET |
|
| |
|
|
| 1 | 2 | 3 |
|
| CLEAR |
|
| |
CD1 |
|
| 4 | 5 | 6 |
| POWER |
|
|
|
|
|
| CLONE RX |
|
| |
CD2 | MUTE |
| 7 | 8 | 9 |
|
| CLONE TX |
|
| |
DM1 |
|
| E | 0 | M |
|
| CLONE/ |
|
|
|
| VOL | LEARN | OK |
|
|
DM2 |
|
|
| PWR | |
| ERROR |
| |||
|
|
|
| ||
|
| LEARN |
|
| |
AMFM | VOL |
|
|
| PLAY |
|
|
|
|
IR SENSOR
TAPE
16.) Numeric Entry
17.) Enter Button
18.) Macro Button
19.) Skip Backward
20.) Skip Forward
21.) Power On
22.) Reverse
23.) Forward
24.) Play
25.) Pause
26.) Stop
8.) Reset - This resets the local zone controller if an IR command “locks up” the zone. It will not erase the local zone memory. It will just send a local clear command.
9.) Clear - This button has 3 modes: a.) Device mode - will clear learned commands from the local zone memory. If you press clear and then say source selector #1 then the commands associated with that page of memory will be erased. b.) Storage mode - this will allow any individual key to be erased and reprogrammed. c.) Macro memory mode - this will allow you to reprogram a individual macro key (0
(This is a permanent erase function, so be careful with this command.)
10.) Clone RX - This button will place the controller into a “ready to receive commands” mode. This is the learning mode. When setting up the system initially, place all but one controller in this mode and use the one master controller to teach the local zones their commands. The clone/learn LED will light and stay on. When the data is received correctly, the red LED will go out and the green OK light will go on. This process takes between 6 and 8 minutes. *See detailed “clone” description on page 8.
11.) Clone TX - This button will place the controller into a “ready to transmit commands” mode. This is the teaching mode. When setting up the system initially, place one controller in this mode and use it as a master controller to teach the other local zones their commands. The clone/learn LED and OK LED will stay on. When the data is transmitted correctly, the red LED will go out and the green OK light will flash then go off. This process takes between 6 and 8 minutes. *See Page 8.
12.) Clone/Learn LED - This LED will let you know the status of transmit and receive during the learning or teaching processes.
13.) OK - This LED will also let you know the progress of the learning/teaching processes. *See Page 8.
14)Learn Button - This button puts the controller into a learning mode.*See Page 8.
15.) IR Sensor - Use this IR window when teaching a controller new IR commands with an external remote.
Page 6