General Dynamics UP/DN CONVERTER L-BAND, LT-3600 manual Part Number Configuration

Page 8

Integrated L-Band Up/Dn Converter LT3600

CG-1309

 

 

1.8 Part Number Configuration

The Part Number Selection Chart shows configuration options that are set at the factory prior to shipment. The voltage output to J4 and J10 may be changed as required by the customer, however this requires removal of the cover and resetting internal jumper connections. This should be performed by qualified personnel.

 

 

 

 

 

 

 

 

 

 

Base

 

1st Digit

2nd Digit

3rd Digit

4th Digit

Number

 

IF Operation

L-Band

Bias Voltage

Ref. Oscillator

201667

-

1

70 MHZ

1

Std.

0

None

0

Std 10Mhz

 

 

 

 

 

 

 

D/C-22VDC

 

 

 

 

2

140 MHz

2

Extend

1

1

Hi Accuracy

 

 

 

 

 

 

 

U/C-22VDC

 

10 MHz

 

 

 

 

 

 

2

D/C-22VDC

 

 

 

 

 

 

 

 

 

U/C-15VDC

 

 

 

 

 

 

 

 

5th Digit

6th Digit

7th Digit

L-Band Ports

10 MHZ Ref. Out

StarSwitch Ready

0

SMA Female

0

No Output

0

No

1

N-Type Female

1

U/C & D/C

1

Yes

 

 

2

U/C Only

 

 

 

 

3

D/C Only

 

 

Note: If connected to a StarSwitch, No Bias Voltage Output is allowed.

Option Descriptions:

1st Digit – IF Frequency, Options 3 and 4 are set for inverted spectrum.

2nd Digit – Standard – 950 to 1525 MHz, Extended – 950 to 1950 MHz

3rd Digit – Bias voltage outputs are switchable in rear panel, if selected.

4th Digit – A reference oscilator is built in to the main board. The high accuracy unit is optional. 5th Digit – D/C Input and U/C Output Port Type (J4 & J10)

6th Digit – The output from the 10 MHz reference oscilator may be connected to either or both. 7th Digit – StarSwitch Ready includes output connections to J5 and J8 for control between the

Starswitch and the LT3600.

Page 8

Image 8
Contents REV C Warranty Table of Contents General Data Format …………………………………………………………………20 List of Tables Section General InformationFront Panel w/Keypad and LCD Display Part Number Configuration Integrated L-Band Specifications External Reference Input Interface and Connectors Installation Operational Check Operation 1200.000 +25.0 dB 1300.000 +35.0 dBDisplay Satellite Memory StarSwitch Display Auto Selection StandBy Mode Backup Converter Operation Front Panel Alarm Settings Serial Command Set AaC2xxxxx Where xxxxx = First 4 numeric data characters DOWN/Converter LNB Spectrum Control Status Requests AaFx Where = numeric character Range 0 to 5 dB/500 MHz Query Card Type Appendix C Display Panel Software Revision History Appendix a Manual Revision HistoryAppendix B CCA Software Revision History

UP/DN CONVERTER L-BAND, LT-3600 specifications

The General Dynamics LT-3600 is an advanced UP/DN converter designed specifically for L-band applications, tailored to meet the rigorous demands of modern communication and broadcasting systems. Known for its reliability and versatility, the LT-3600 supports a wide range of operational environments, making it a preferred choice for military, aerospace, and commercial users.

One of the standout features of the LT-3600 is its ability to provide high-performance frequency translation with minimal signal degradation. The device operates within a frequency range typically from 950 MHz to 2150 MHz, allowing it to effectively handle various input and output frequencies, which is crucial for seamless integration into existing systems.

The LT-3600 employs advanced digital signal processing (DSP) technologies that enhance its performance in terms of linearity, noise figures, and phase stability. This results in superior signal clarity and reduced interference, ensuring that the converted signals maintain their integrity over long distances. The use of high-quality mixers and filters further contributes to its exceptional performance metrics, making it suitable for critical applications where signal fidelity is paramount.

In terms of usability, the LT-3600 boasts a user-friendly interface that facilitates ease of setup and operation. It is equipped with intuitive controls and indicators that provide real-time feedback on operational status, which is essential for monitoring performance during live operations. The device also offers options for both manual and remote control, enhancing its flexibility for different operational requirements.

Another significant characteristic of the LT-3600 is its robust design, featuring rugged components that can withstand adverse environments. The unit is engineered to comply with military standards, making it suitable for deployment in harsh conditions, including extreme temperatures and humidity. This reliability is critical for military and aerospace applications where equipment failures can lead to severe consequences.

Additionally, the LT-3600 supports various modulation schemes and can be easily integrated into systems requiring diverse communication protocols. This adaptability ensures that users can customize the unit to meet specific requirements, enhancing its appeal across multiple industries.

In summary, the General Dynamics LT-3600 UP/DN converter stands out for its advanced features, including superior signal quality, user-friendly operation, and rugged reliability. Its combination of innovative technologies and practical design makes it an essential component for anyone seeking high-performance L-band solutions in challenging environments.