Enterasys Networks 4H4284-49, 4H4202-72, 4H4283-49, 4H4282-49, 4H4203-72 manual Figures

Page 15

Figures

1-1

4H4282-49,4H4283-49, and 4H4203-72DFE-Gold Modules

1-4

1-2

4H4202-72 and 4H4284-49DFE-Gold Modules

1-5

3-1

Examples, Slot Numbers/Module Placement in Matrix E7 Chassis

3-4

3-2

Installing Module into Matrix E7 or N7 Chassis (Matrix E7 shown)

3-8

3-3

Installing Module into Matrix N3, N1, or N5 Chassis (Matrix N3 shown)

3-10

3-4

Connecting a Twisted Pair Segment With RJ45 Connector

3-12

3-5

Four-Wire Crossover Cable RJ45 Pinouts, Connections Between Hub Devices

3-13

3-6

Four-WireStraight-Through Cable RJ45 Pinouts, Connections

 

 

Between Switches and End-User Devices

3-13

3-7

Eight-Wire Crossover Cable RJ45 Pinouts, Connections Between Hub Devices

3-14

3-8

Eight-WireStraight-Through Cable RJ45 Pinouts, Connections

 

 

Between Switches and End-User Devices

3-14

3-9

Connecting a Twisted Pair Using RJ21 Straight Connector

3-16

3-10

Connection Using Optional RJ21 Angle Adapter

3-17

3-11

Connecting a Fiber-Optic Segment to MT-RJ Front Panel Connector

3-19

3-12

Connecting an IBM PC or Compatible

3-22

3-13

Connecting a VT Series Terminal

3-23

3-14

Connecting to a Modem

3-24

3-15

Matrix DFE Startup Screen Example (N7 Chassis)

3-28

4-1

LANVIEW LEDs on 4H4282-49,4H4283-49, and 4H4203-72

4-2

4-2

LANVIEW LEDs on 4H4202-72

4-3

4-3

LANVIEW LEDs on 4H4284-49

4-4

4-4

OFFLINE/RESET Switch

4-9

B-1

Mode Switch Location on 4H4282-49 and 4H4283-49

B-3

B-2

Mode Switch Location on 4H4203-72

B-3

B-3

Mode Switch Location on 4H4202-72

B-4

B-4

Mode Switch Location on 4H4284-49

B-4

B-5

DIMM/DRAM SIMM Locations (for 4H4282-49,4H4283-49,4H4284-49)

B-5

B-6

DIMM and DRAM SIMM Locations (4H4203-72)

B-6

B-7

DIMM and DRAM SIMM Locations (4H4202-72)

B-6

B-8

NEM Removal and DIMM Connector Location (4H4282-49/4H4283-49)

B-8

B-9

Removing the Existing DIMM from 4H4282-49 or 4H4283-49

B-9

B-10

Installing the DIMM on 4H4282-49 or 4H4283-49

B-10

B-11

Removing Existing DIMM from 4H4203-72

B-11

B-12

Installing the DIMM on 4H4203-72

B-12

B-13

Removing the Existing DRAM SIMM

B-13

B-14

Installing the DRAM SIMM

B-14

xiii

Image 15
Contents Enterasys Matrix Page Page Regulatory Compliance Information Electromagnetic Compatibility EMC Supplement to Product Instructions Vcci Notice Declaration of Conformity Enterasys Networks, Inc Firmware License Agreement Viii Page Page Contents Troubleshooting Appendix a SpecificationsIndex Figures Tables Contents of DFE-Gold Module CartonAbout This Guide Who Should Use This GuideImportant Notice How to Use This Guide Related DocumentsFor Refer to Following conventions are used in this guide Conventions Used in This GuideGetting Help Overview of DFE-Gold Series Capabilities IntroductionDFE-Gold Modules 4H4282-494H4283-49 4H4203-72 4H4202-724H4284-49 DFE 4H4202-72 and 4H4284-49 DFE-Gold Modules Connectivity Standards Compatibility Switch Configuration Using WebViewSwitch Configuration Using CLI Commands ManagementLanview Diagnostic LEDs 10BASE-T Network Network Requirements100BASE-FX Fiber-Optic Network 100BASE-TX NetworkInstallation Installation Site Requirement Contents of DFE-Gold Module Carton QuantityUnpacking the DFE-Gold Module DFE Module Placement and Installation Rules Installing Optional Network Expansion ModuleExample 2 -1, B Example 1 -1, aInstalling Module into a Chassis Example 3 -1, CExample 4 -1, D Preparation Installing Module into Matrix E7 or N7 ChassisInstalling Module into a Chassis ➆ ➁ Installing Module into Matrix N1, N3, or N5 Chassis Connecting to the Network Connecting to the NetworkConnecting UTP Cables to 4H4282-49 or 4H4202-72 Connecting a Twisted Pair Segment With RJ45 Connector RX+ TX+ TX1+ RX1 TX2+ TX3+ RX3 RX2 TX4+ RX4 Connecting UTP Cables to 4H4283-49 or 4H4203-72 Connecting a Twisted Pair Using RJ21 Straight Connector 10 Connection Using Optional RJ21 Angle Adapter Connecting Fiber-Optic Cables to 4H4284-49 COM Mgmt CPU What Is Needed Connecting to COM Port for Local ManagementParameter Setting Connecting to an IBM PC or Compatible Device12 Connecting an IBM PC or Compatible Connecting to a VT Series Terminal13 Connecting a VT Series Terminal Connecting to a Modem14 Connecting to a Modem Adapter Wiring and Signal Assignments COM Port Adapter Wiring and Signal Diagram RJ45VT Series Port Adapter Wiring and Signal Diagram RJ45 DB25 Completing the Installation Completing the Installation of a New SystemModem Port Adapter Wiring and Signal Diagram RJ45 DB25 First-Time Log-In Using a Console Port Connection 15 Matrix DFE Startup Screen Example N7 Chassis Enter Logging in with an Administratively-Configured User AccountCompleting the Installation Troubleshooting Using LanviewAbout the Management Mgmt LED Lanview LEDs on 4H4282-49, 4H4283-49, and 4H4203-72 Lanview LEDs on 4H4202-72 Viewing Receive/Transmit Activity on 4H4202-72Lanview LEDs on 4H4284-49 Viewing the Receive and Transmit Activity on 4H4284-49Color State Recommended Action Lanview LEDsLED Refer to the Enterasys Matrix DFE-Gold Series Troubleshooting ChecklistEnterasys Matrix DFE-Gold Series Configuration OFFLINE/RESET Switch Overview of DFE-Gold Module Shutdown ProcedureLast Resort Shutdown Procedure Using OFFLINE/RESET Switch Recommended Shutdown Procedure Using OFFLINE/RESET SwitchSpecifications DFE-Gold Module SpecificationsTable A-1 Specifications Chassis Backplane Connectivity COM Port Pinout Assignments Table A-2 COM Port Pin Assignments Signal Name Input/OutputTable A-3 Compliance Standards Regulatory Compliance Regulatory ComplianceRequired Tools Mode Switch Bank Settings Optional InstallationsSetting the Mode Switches Figure B-1 Mode Switch Location on 4H4282-49 and 4H4283-49 Figure B-3 Mode Switch Location on 4H4202-72 Location of Dimm and Dram Simm Memory Modules Memory Locations and Replacement ProceduresFigure B-6 Dimm and Dram Simm Locations 4H4203-72 Removing the Dram Simm Dimm Replacement Procedure 4H4282-49 and 4H4283-49Installing the Dram Simm on 4H4282-49 or 4H4283-49 Removing the Dram Simm from 4H4203-72 Figure B-11 Removing Existing Dram Simm from 4H4203-72 Installing the Dram Simm on 4H4203-72Figure B-12 Installing the Dram Simm on 4H4203-72 Dram Simm Replacement 4H4202-72Removing the Dimm Dimm Replacement Procedure All DFE ModulesFigure B-14 Installing the Dimm Installing the DimmPage Numerics IndexOFFLINE/RESET button 4-10Optional network expansion module
Related manuals
Manual 90 pages 58.47 Kb

4H4203-72, 4H4283-49, 4H4282-49, 4H4202-72, 4H4284-49 specifications

Enterasys Networks has long been a leader in providing robust networking solutions for enterprises, and their range of products, including models 4H4284-49, 4H4202-72, 4H4282-49, 4H4283-49, and 4H4203-72, exemplifies their commitment to delivering high-performance networking equipment. These models are designed to meet the increasing demands of modern network environments, ensuring scalability, reliability, and security.

One of the standout features of the Enterasys Networks products is their advanced Layer 2 and Layer 3 switching capabilities. This allows for efficient data transmission and fundamental network routing processes, making them ideal for both small business networks and large enterprise setups. The models boast high throughput rates and low latency, which are essential for applications requiring real-time data transfer, such as video conferencing and VoIP.

Additionally, these switches are equipped with Power over Ethernet (PoE) functionality, enabling users to power devices like IP phones, wireless access points, and security cameras directly from the switch. This eliminates the need for additional electrical wiring, simplifying installation and reducing costs. The power budget is adequately managed, ensuring that all connected devices operate efficiently.

In terms of security, Enterasys Networks has integrated advanced features such as VLAN support and Access Control Lists (ACLs) to enhance network segmentation and safeguard against unauthorized access. This is particularly crucial in environments where sensitive data is handled. The inclusion of network monitoring and management tools further aids IT teams in maintaining optimal network performance and detecting potential issues proactively.

Moreover, these models support a variety of networking protocols, which adds flexibility and compatibility with existing infrastructure. The user-friendly web interface and CLI enable easy configuration and management, catering to network administrators' diverse levels of expertise.

Built with high-quality materials, Enterasys Networks devices are designed to withstand the rigors of a data center environment, ensuring longevity and reliable performance. The combination of these features makes the 4H4284-49, 4H4202-72, 4H4282-49, 4H4283-49, and 4H4203-72 models excellent choices for organizations looking to enhance their networking capabilities and ensure a secure, efficient communication network that can grow with their needs. Overall, Enterasys Networks continues to set benchmarks in networking technology, making significant strides in improving connectivity and performance for enterprises worldwide.