Enterasys Networks 4H4283-49, 4H4284-49 manual First-Time Log-In Using a Console Port Connection

Page 57

Completing the Installation

First-Time Log-In Using a Console Port Connection

Note: This procedure applies only to initial log-in, and to logging in to a device not yet configured with administratively-supplied user and password settings.

By default, the Matrix DFE Series device is configured with three user login accounts: ro for Read-Only access; rw for Read-Write access; and admin for super-user access to all modifiable parameters. The default password is set to blank (carriage return). For information on changing these default passwords, refer to Chapter 3 in the Enterasys Matrix DFE-Gold Series Configuration Guide.

Start the Command Line Interface (CLI) from the module’s local console port as follows:

1.Connect a terminal to the local console port as described in “Connecting to COM Port for Local Management” on page 3‐20. The startup screen, Figure 3‐15, displays.

2.At the login prompt, enter one of the following default user names:

ro for Read‐Only access,

rw for Read‐Write access, or

admin for Super User access. (This access level allows Read‐Write access to all modifiable parameters, including user accounts.)

3.Press ENTER.

4.The Password prompt displays. Leave this string blank and press ENTER. The module information and Matrix prompt displays as shown in Figure 3‐15.

The DFE‐Gold module is now ready to be configured. For information about setting the IP address and configuring Telnet settings for remote access to DFE management, refer to Chapter 3 in the Enterasys Matrix DFE‐Gold Series Configuration Guide. The CLI commands enable you to initially set up and perform more involved management configurations.

The Enterasys Matrix DFE‐Gold Series Configuration Guide is available online at:

http://www.enterasys.com/support/manuals

If you require assistance, contact Enterasys Networks using one of the methods described in “Getting Help” on page xviii.

Matrix DFE-Gold Series Modules Hardware Installation Guide 3-27

Image 57
Contents Enterasys Matrix Page Page Regulatory Compliance Information Electromagnetic Compatibility EMC Supplement to Product Instructions Vcci Notice Declaration of Conformity Enterasys Networks, Inc Firmware License Agreement Viii Page Page Contents Troubleshooting Appendix a SpecificationsIndex Figures Tables Contents of DFE-Gold Module CartonAbout This Guide Who Should Use This GuideImportant Notice How to Use This Guide Related DocumentsFor Refer to Following conventions are used in this guide Conventions Used in This GuideGetting Help Overview of DFE-Gold Series Capabilities IntroductionDFE-Gold Modules 4H4282-494H4283-49 4H4203-72 4H4202-724H4284-49 DFE 4H4202-72 and 4H4284-49 DFE-Gold Modules Connectivity Switch Configuration Using CLI Commands Switch Configuration Using WebViewManagement Standards CompatibilityLanview Diagnostic LEDs 10BASE-T Network Network Requirements100BASE-FX Fiber-Optic Network 100BASE-TX NetworkInstallation Installation Site Requirement Contents of DFE-Gold Module Carton QuantityUnpacking the DFE-Gold Module DFE Module Placement and Installation Rules Installing Optional Network Expansion ModuleExample 2 -1, B Example 1 -1, aInstalling Module into a Chassis Example 3 -1, CExample 4 -1, D Preparation Installing Module into Matrix E7 or N7 ChassisInstalling Module into a Chassis ➆ ➁ Installing Module into Matrix N1, N3, or N5 Chassis Connecting to the Network Connecting to the NetworkConnecting UTP Cables to 4H4282-49 or 4H4202-72 Connecting a Twisted Pair Segment With RJ45 Connector RX+ TX+ TX1+ RX1 TX2+ TX3+ RX3 RX2 TX4+ RX4 Connecting UTP Cables to 4H4283-49 or 4H4203-72 Connecting a Twisted Pair Using RJ21 Straight Connector 10 Connection Using Optional RJ21 Angle Adapter Connecting Fiber-Optic Cables to 4H4284-49 COM Mgmt CPU What Is Needed Connecting to COM Port for Local ManagementParameter Setting Connecting to an IBM PC or Compatible Device12 Connecting an IBM PC or Compatible Connecting to a VT Series Terminal13 Connecting a VT Series Terminal Connecting to a Modem14 Connecting to a Modem Adapter Wiring and Signal Assignments COM Port Adapter Wiring and Signal Diagram RJ45VT Series Port Adapter Wiring and Signal Diagram RJ45 DB25 Completing the Installation Completing the Installation of a New SystemModem Port Adapter Wiring and Signal Diagram RJ45 DB25 First-Time Log-In Using a Console Port Connection 15 Matrix DFE Startup Screen Example N7 Chassis Enter Logging in with an Administratively-Configured User AccountCompleting the Installation Troubleshooting Using LanviewAbout the Management Mgmt LED Lanview LEDs on 4H4282-49, 4H4283-49, and 4H4203-72 Lanview LEDs on 4H4202-72 Viewing Receive/Transmit Activity on 4H4202-72Lanview LEDs on 4H4284-49 Viewing the Receive and Transmit Activity on 4H4284-49Color State Recommended Action Lanview LEDsLED Refer to the Enterasys Matrix DFE-Gold Series Troubleshooting ChecklistEnterasys Matrix DFE-Gold Series Configuration OFFLINE/RESET Switch Overview of DFE-Gold Module Shutdown ProcedureLast Resort Shutdown Procedure Using OFFLINE/RESET Switch Recommended Shutdown Procedure Using OFFLINE/RESET SwitchSpecifications DFE-Gold Module SpecificationsTable A-1 Specifications Chassis Backplane Connectivity COM Port Pinout Assignments Table A-2 COM Port Pin Assignments Signal Name Input/OutputTable A-3 Compliance Standards Regulatory Compliance Regulatory ComplianceRequired Tools Mode Switch Bank Settings Optional InstallationsSetting the Mode Switches Figure B-1 Mode Switch Location on 4H4282-49 and 4H4283-49 Figure B-3 Mode Switch Location on 4H4202-72 Location of Dimm and Dram Simm Memory Modules Memory Locations and Replacement ProceduresFigure B-6 Dimm and Dram Simm Locations 4H4203-72 Removing the Dram Simm Dimm Replacement Procedure 4H4282-49 and 4H4283-49Installing the Dram Simm on 4H4282-49 or 4H4283-49 Removing the Dram Simm from 4H4203-72 Figure B-11 Removing Existing Dram Simm from 4H4203-72 Installing the Dram Simm on 4H4203-72Figure B-12 Installing the Dram Simm on 4H4203-72 Dram Simm Replacement 4H4202-72Removing the Dimm Dimm Replacement Procedure All DFE ModulesFigure B-14 Installing the Dimm Installing the DimmPage Numerics IndexOFFLINE/RESET button 4-10Optional network expansion module
Related manuals
Manual 90 pages 58.47 Kb

4H4203-72, 4H4283-49, 4H4282-49, 4H4202-72, 4H4284-49 specifications

Enterasys Networks has long been a leader in providing robust networking solutions for enterprises, and their range of products, including models 4H4284-49, 4H4202-72, 4H4282-49, 4H4283-49, and 4H4203-72, exemplifies their commitment to delivering high-performance networking equipment. These models are designed to meet the increasing demands of modern network environments, ensuring scalability, reliability, and security.

One of the standout features of the Enterasys Networks products is their advanced Layer 2 and Layer 3 switching capabilities. This allows for efficient data transmission and fundamental network routing processes, making them ideal for both small business networks and large enterprise setups. The models boast high throughput rates and low latency, which are essential for applications requiring real-time data transfer, such as video conferencing and VoIP.

Additionally, these switches are equipped with Power over Ethernet (PoE) functionality, enabling users to power devices like IP phones, wireless access points, and security cameras directly from the switch. This eliminates the need for additional electrical wiring, simplifying installation and reducing costs. The power budget is adequately managed, ensuring that all connected devices operate efficiently.

In terms of security, Enterasys Networks has integrated advanced features such as VLAN support and Access Control Lists (ACLs) to enhance network segmentation and safeguard against unauthorized access. This is particularly crucial in environments where sensitive data is handled. The inclusion of network monitoring and management tools further aids IT teams in maintaining optimal network performance and detecting potential issues proactively.

Moreover, these models support a variety of networking protocols, which adds flexibility and compatibility with existing infrastructure. The user-friendly web interface and CLI enable easy configuration and management, catering to network administrators' diverse levels of expertise.

Built with high-quality materials, Enterasys Networks devices are designed to withstand the rigors of a data center environment, ensuring longevity and reliable performance. The combination of these features makes the 4H4284-49, 4H4202-72, 4H4282-49, 4H4283-49, and 4H4203-72 models excellent choices for organizations looking to enhance their networking capabilities and ensure a secure, efficient communication network that can grow with their needs. Overall, Enterasys Networks continues to set benchmarks in networking technology, making significant strides in improving connectivity and performance for enterprises worldwide.