Cisco Systems VG350 specifications Port Numbering Conventions, Online Insertion and Removal

Page 34

Chapter 2 Cisco Double-Wide High Density Analog Service Modules

Port Numbering Conventions

Port Numbering Conventions

Port numbering conventions for the Cisco VG350 Voice Gateway are as follows:

Two Compact Flash slots, CF0 and CF1.

GE ports are 10/100/1000 BASE-T, numbered GE 0/0 through GE 0/2.

10/100BASE-T ports are numbered 10/100BASE-T 0/0 and 10/100BASE-T 0/1 from right to left.

FXS voice port numbering begins at 2/0/0 to 2/0/71 or 2/0/47 and 4/0/0 to 4/0/71 or 4/0/47, depending on the number of voice ports.

The ports numbered 2/0/x are for the SM installed in slot 1 and the ports numbered 4/0/x are for the Service Module (SM) installed in slot 2.

Connecting to the Double-Wide High Density Service Module Ports

Three RJ-21 female connectors are available on the SM-D-72FXS service module. The middle RJ-21 connector accesses FXS ports 0 to 23, the left RJ-21 female connector accesses ports 24 to 4, and the right RJ-21 connector accesses ports 48 to 71. Use RJ-21 male connector to connect from the DWSM RJ-21 ports to an FXS port RJ-11 distribution box.

Note Use an RJ-21 cable with Amphenol 50-pin connectors.

Online Insertion and Removal

The DWSM can be hot-inserted into the VG350 Voice Gateway without any potential of electrical damage either to the SM or the Host because the Online Insertion and Removal (OIR) logic is present on all SM designs.

OIRl is the ability to insert and remove an SM while the system is running without causing electrical damage to the SM or Host and without interfering with the operation of any other modules or portions of a running system.

The basic feature for OIR support on an SM is the control and isolation of the 12V power rail via a field-effect transistor (FET). This FET is enabled in a controlled fashion after the SM card is fully inserted.

Cisco VG350 Voice Gateway Hardware Installation Guide

 

OL-25970-01

2-7

 

 

 

Image 34
Contents Cisco VG350 Voice Gateway Hardware Installation Guide Americas HeadquartersPage N T E N T S Grounding Site Log Organization AudienceChapter Title Description Conventions Convention DescriptionSäilytä Nämä Ohjeet Safety WarningsBewaar Deze Instructies Conservez CES InformationsTA Vare PÅ Disse Instruksjonene Bewahren SIE Diese Hinweise GUT AUFConservare Queste Istruzioni Guarde Estas InstruçõesSpara Dessa Anvisningar GEM Disse Anvisninger Xiii Xiv Obtaining Documentation Related DocumentationCisco.com Ordering Documentation Documentation FeedbackObtaining Technical Assistance Cisco Technical Support WebsiteSubmitting a Service Request Definitions of Service Request SeverityObtaining Additional Publications and Information Overview USBVG350 Voice Gateway Chassis AC OKConfiguration Options Interfaces and Service CapabilitiesSFP LED LED IndicatorsPhysical Description and LEDs Color DescriptionCF0/CF1 Description Specification SpecificationsSFP Transportation and Storage SD/EMI Configuration Methods Configuration ConnectionsSoftware Elements OL-25970-01 Cisco Double-Wide High Density Analog Service Modules SM-D-72FXS SM-D-48FXS-E FXS-EInstalling SM-D-72FXS GroundingInstalling SM-D-48FXS-E Connecting SM-D-48FXS-EFXO Faceplate Label RJ-11 OUT RJ-11 Power on Power OFFFXO Fail-Over Bypass Ports BYPASS-0Physical Description and LEDs Cisco SM-D-72FXS Service Module SpecificationsCisco SM-D-48FXS-E Service Module Specifications EN LEDPort Numbering Conventions Online Insertion and RemovalInsertion and Removal Steps InsertionTemperature Control and Ventilation Location and Mounting RequirementsAccess to Chassis Chassis GroundingPower Source Power Suppy ConsiderationsGigabit Ethernet Maximum Distance Distance Limitations for Interface CablesCable Types FXS Analog Voice Port Maximum DistanceInterference Considerations OL-25970-01 Installing the Cisco VG350 Voice Gateway Safety Recommendations Maintaining Safety with ElectricityPage General Safety Practices Safety TipsSite Log Preventing Electrostatic Discharge DamageInstallation Checklist Keeping Track-ChecklistTask Verified by Date Mounting Tools and Equipment Unpacking and InspectionOL-25970-01 Checklist for Power-On Powering On the Cisco VG350 Voice GatewayPower-On Procedure Continue with the Troubleshooting section on Troubleshooting Symptom Possible Cause Corrective ActionOL-25970-01 Cable Specifications and Information Console and Auxiliary Port Cables and PinoutsGND Console Port to PCRTS CTS DTR DSR DSR DTR CTS RTSConsole Port to Ascii Terminal Figure A-2 Console Port to Ascii Terminal-Cable and AdapterRTS DTR Auxiliary Port to ModemAlternative Connections to Terminal and Modem DSR DCD CTSTX+ Pin SignalGigabit Ethernet Port Pinouts RJ-45 RX+Port Connector Pin Number Signal Analog Voice Multiport Pinouts RJ-21X/CA21ARing Tip 25, 50, 51