Cisco Systems VG350 specifications Transportation and Storage

Page 24

Chapter 1 Overview of the Cisco VG350 Voice Gateway

Physical Description and LEDs

Table 1-4

Cisco VG350 Voice Gateway Technical Specifications (continued)

 

 

 

 

 

 

Description

 

 

Specification

 

 

 

 

 

 

Temperature

 

 

23 to 122°F (–5°C to 50°C)

 

(short-term per NEBS/1800m

 

 

 

 

 

max altitude)

 

 

 

 

 

 

 

 

 

Operating altitude maximum

13,123 ft (4000 m)

 

 

 

 

 

 

 

 

 

 

 

Note For China, the unit cannot operate above 2000 m. The internal AC power supplies

 

 

 

 

 

 

do not meet the new Chinese Safety requirements for products that operate in the

 

 

 

 

 

 

2001-5000 m range.

 

 

 

 

 

 

 

 

 

 

 

 

 

Transportation and Storage

 

 

 

 

 

 

 

 

 

Non-operating temperature

 

–40 to 158°F (–40 to 70°C)

 

 

 

 

 

Non-operating humidity

 

5 to 95% RH

 

 

 

 

 

Non-operating altitude

 

15,000 ft (4570 m)

 

 

 

 

 

 

 

 

Acoustic

 

 

 

 

 

 

 

 

 

 

Acoustic: Sound Pressure

 

57.6 to 77.6 dBA

 

(Typical/Maximum)

 

 

 

 

 

 

 

 

 

Acoustic: Sound Power

 

67.8 to 84.7 dBA

 

(Typical/Maximum)

 

 

 

 

 

 

 

 

 

 

 

 

Compliance

 

 

 

 

 

 

 

 

 

 

Safety compliance

 

IEC 60950-1, Safety of information technology equipment

 

 

 

 

EN 60950-1, Safety of information technology equipment

 

 

 

 

UL 60950-1, Standard for safety for information technology

 

 

 

 

equipment [US]

 

 

 

 

CAN/CSA C22.2 No. 60950-1, Safety of information technology

 

 

 

 

equipment including electrical business equipment [Canada]

 

 

 

 

AS/NZS 60950.1 2003

 

 

 

 

IEC60950, 3rd edition [PRC]

 

 

 

 

IEC60950, 2nd Edition [Mexico]

 

 

 

 

 

 

 

 

Cisco VG350 Voice Gateway Hardware Installation Guide

 

OL-25970-01

1-7

 

 

 

Image 24
Contents Cisco VG350 Voice Gateway Hardware Installation Guide Americas HeadquartersPage N T E N T S Grounding Site Log Audience OrganizationChapter Title Description Conventions Convention DescriptionSafety Warnings Bewaar Deze InstructiesSäilytä Nämä Ohjeet Conservez CES InformationsBewahren SIE Diese Hinweise GUT AUF Conservare Queste IstruzioniTA Vare PÅ Disse Instruksjonene Guarde Estas InstruçõesSpara Dessa Anvisningar GEM Disse Anvisninger Xiii Xiv Related Documentation Obtaining DocumentationCisco.com Documentation Feedback Obtaining Technical AssistanceOrdering Documentation Cisco Technical Support WebsiteSubmitting a Service Request Definitions of Service Request SeverityObtaining Additional Publications and Information Overview USBVG350 Voice Gateway Chassis AC OKInterfaces and Service Capabilities Configuration OptionsSFP LED Indicators Physical Description and LEDsLED Color DescriptionCF0/CF1 Specifications Description SpecificationSFP Transportation and Storage SD/EMI Configuration Connections Configuration MethodsSoftware Elements OL-25970-01 Cisco Double-Wide High Density Analog Service Modules SM-D-72FXS SM-D-48FXS-E FXS-EInstalling SM-D-72FXS GroundingInstalling SM-D-48FXS-E Connecting SM-D-48FXS-EFaceplate Label RJ-11 OUT RJ-11 Power on Power OFF FXO Fail-Over Bypass PortsFXO BYPASS-0Cisco SM-D-72FXS Service Module Specifications Cisco SM-D-48FXS-E Service Module SpecificationsPhysical Description and LEDs EN LEDPort Numbering Conventions Online Insertion and RemovalInsertion and Removal Steps InsertionTemperature Control and Ventilation Location and Mounting RequirementsAccess to Chassis Chassis GroundingPower Source Power Suppy ConsiderationsDistance Limitations for Interface Cables Cable TypesGigabit Ethernet Maximum Distance FXS Analog Voice Port Maximum DistanceInterference Considerations OL-25970-01 Installing the Cisco VG350 Voice Gateway Safety Recommendations Maintaining Safety with ElectricityPage General Safety Practices Safety TipsSite Log Preventing Electrostatic Discharge DamageKeeping Track-Checklist Installation ChecklistTask Verified by Date Mounting Tools and Equipment Unpacking and InspectionOL-25970-01 Powering On the Cisco VG350 Voice Gateway Checklist for Power-OnPower-On Procedure Continue with the Troubleshooting section on Troubleshooting Symptom Possible Cause Corrective ActionOL-25970-01 Cable Specifications and Information Console and Auxiliary Port Cables and PinoutsConsole Port to PC RTS CTS DTR DSRGND DSR DTR CTS RTSConsole Port to Ascii Terminal Figure A-2 Console Port to Ascii Terminal-Cable and AdapterAuxiliary Port to Modem Alternative Connections to Terminal and ModemRTS DTR DSR DCD CTSPin Signal Gigabit Ethernet Port Pinouts RJ-45TX+ RX+Port Connector Pin Number Signal Analog Voice Multiport Pinouts RJ-21X/CA21ARing Tip 25, 50, 51
Related manuals
Manual 60 pages 46.05 Kb