Agilent Technologies 85107B, 8510XF manual 8530A microwave receiver and 8510C

Page 10
8510C

Upgrading the 8510 to the 8530 microwave receiver for antenna measurements

Figure 7 below illustrates how the 8510C can be upgraded to either an 8530A or 8530A and 8510C. For example, to upgrade an 8510C to an 8530A, order 85395C with Option 111.

85395C2 Opt.111

8510C

8530A

85396A

microwave

 

receiver

 

 

 

Figure 7. 8510 to 8530 upgrade paths

85395C2

8530A

microwave receiver and 8510C

network analyzer capability

Agilent 85395C2 Upgrades any 8510C to an 8530A. Retains network analyzer capability. Includes on-site installation by Customer Engineer (where available). Other requirements may apply (such as 8530 firmware).1

The following options are available:

Option 010 adds time domain capability

Option 111 deletes network analyzer capability

Agilent 85396A Adds 8510C Network Analyzer capability to any 8530A (equivalent to 8530A Option 011).

Option 010 adds time domain capability

1.For additional information, please refer to the Agilent 85395A/B/C and 85396A Upgrade Kits, literature number 5091-0948E.

2.Requires an 85101C with serial prefix 3936A or lower

10

Image 10
Contents Product Note Agilent Upgrade Guide for the Vector Network Analyzeron-wafer configuration 85107B, 45 MHz to 50 GHz in coaxTable of Contents Source Signal separationVector network analyzer VNA overview Receiver/Detector Processor/Display8510Receiver/detector network 8510 VNA = systemSignal analyzerFigure 4. 8510 family of system solutions Agilent 8510 family of productsAgilent 8510 network analyzer Table 1. Hardware revision and measurement capabilityTable 2. Firmware revision and measurement capability Agilent 8510 Firmware upgrade kitsFigure 5. 8510 firmware upgrade kits 8510CTest Sets Table 3. Family of test setsTable 4. 8510-dedicated sources SourcesTable 5. 8360 general purpose synthesizers Upgrading the Upgrade considerationsUpgrading individual components 85103E8530A microwave receiver and 8510C 8510C8530A Figure 7. 8510 to 8530 upgrade pathsAdding pulse capabilities Option Test set upgradesExpanding measurement capabilities Adding time domain capabilitiesUpgrading systems + ORFigure 8. 8510 family of system solutions 2. What test set do I need? System upgrades4. What measurement accessories do I need? 3. What source do I need?Upgrades for 85107B, 85109C Upgrade to 85106D waveguide system to operate in V-band Examples of upgrade pathsMeasurement accessories 85107B 45 MHz to 50 GHz current systemCalibration kits Configuration A Network analyzer test set Verification kitsTest port cables and adapters Device under testFor 85110L Test sets 7 mm rugged test port connectors Configuration B Network analyzer test set Cable set Device under testFor 8514B/8515A/85110A test sets 3.5 mm rugged test port connectors For 8517B Test sets 2.4 mm rugged test port connectorsProduct overviews Related literaturePub. number Product notesand Assistance Agilent Technologies’ Test and Measurement Support, ServicesFor more information on the 8510 VNA visit Our Promise